§ 815.4.030: Definitions.
Notwithstanding the applicable definitions, symbols and notations in the Building Code, the following definitions shall apply for the purposes of this Chapter: a) BUILDING CODE Is the current Building Code of the City of Torrance. b) HISTORICAL BUILDING Is any building designated, or currently in the process of being designated, as a "qualified historical building" as defined in Part 8, Title 24 of the California Code of Regulations. c) LOAD PATH DEFICIENCY OCCURS When a structure does not contain a complete, well defined load path, including structural elements and connections that serves to transfer the inertial forces associated with the mass of all elements of the building to the foundation. d) OWNER OR BUILDING OWNER Is the individual(s), agent, firm, corporation, or entity having legal possession, equitable interest in the property, or rights to sanction evaluation or retrofit of a building. e) RETROFIT Is an improvement of the lateral force resisting system by alteration of existing structural elements or addition of new structural elements. f) SOFT STORY DEFICIENCY OCCURS When the stiffness of the seismic-force-resisting system in any Story is less than 70% of the seismic-force-resisting system in an adjacent Story above or less than 80% of the average seismic-force system stiffness of the three stories above. g) STEEL MOMENT FRAME Is a frame capable of resisting horizontal forces caused by the steel members (beams and column) and joints resisting forces primarily by flexure. h) STORY Is as defined in the Building Code, but includes any basement or underfloor space of a building with cripple walls exceeding four feet in height. i) TORSION DEFICIENCY OCCURS When the estimated distance between the Story center of mass and the Story center of rigidity is more than 20% of the building width in either plan dimension. j) VERTICAL IRREGULARITY DEFICIENCY EXISTS When one or more vertical elements in the seismic-force-resisting system are not continuous to the foundation. k) WEAK STORY DEFICIENCY OCCURS When the sum of the shear strengths of the seismic-force-resisting system in any Story in each direction is less than 80% of the strength in the adjacent Story above.
Ask a question about Torrance law
Corpus searches the Torrance sections it holds and shows the ones that match, with their citations. Free, no sign-in.