§ 97.9.6: Chain link fence requirements.

a) All chain link fences used to enclose in whole or in part any oil well site shall meet the following specifications: 1) The fence fabric shall be at least six (6) feet in height. 2) The support posts shall be buried into the ground to a depth which complies with the provisions of the Building Code governing windloading. 3) The fence shall be topped with a V-shaped support for barbed wire. The support shall have an internal and external angle of forty-five (45) degrees (a total angle of ninety (90) degrees). Each side of the V shall have three (3) rows of four (4) point barbed wire equally spaced. 4) The chain link fabric shall be galvanized steel wire with a minimum plating of 1.2 ounces of zinc per square foot of surface area with both selvages barbed. 5) The chain link fence fabric shall have a minimum thickness of eleven (11) gauge. 6) The chain link fabric shall be two (2) inch mesh; provided, however, three and one-half (3-½) inch mesh may be used on any fence where the fabric is interwoven with artificial screening of redwood slats and the Director of Building and Safety determines that the interwoven mesh is equal in safety to a two (2) inch mesh without such slats. 7) Post and rails shall be standard galvanized weld or stainless pipe schedule forty (40) or thicker; provided, however, that non-galvanized drill pipe may be used if it exceeds schedule forty (40) in thickness. 8) All pipe and other ferrous parts, except chain link fabric and drill pipe, shall be galvanized inside and outside with a plating which contains a minimum of 1.2 ounces of zinc per square foot of surface area. 9) Tension rods shall be three-eights (⅜) inch round steel bolt stock. Adjustable tighteners shall be turnbuckle or equivalent having a six (6) inch minimum take up. Tension bars shall have a minimum thickness of ¼ x ¾ inch. 10) Concrete mix shall be Class C. b) In addition to meeting said specifications, all such fences shall be constructed in accordance with standard engineering practices and in accordance with the Torrance General Chain Link Fence Drawing No. 1 on file in the office of the City Engineer.

[Amended by Ord. 1933 ]

Ask a question about Torrance law

Corpus searches the Torrance sections it holds and shows the ones that match, with their citations. Free, no sign-in.