§ 97.9.9: Gate specifications.

All chain link fences and masonry walls shall be equipped with at least one (1) gated area. The gated areas shall meet the following specifications: a) Each gated area shall be twelve (12) feet wide and be composed of two (2) gates each of which is six (6) feet wide. The gates shall latch and lock in the center of the twelve (12) foot span. b) The gates shall be of chain link construction which meets the applicable specifications of Section 97.9.6. and Section 97.9.7 c) They shall be provided with a combination catch and locking attachment device for a padlock, which device shall be approved by the Fire Chief, and shall be kept locked except when being used for access to the site. In making his determination the Fire Chief shall consider whether or not, and the degree to which, such device interferes with the ability of the Fire Department to obtain ingress into the site in case of an emergency. d) Hinges shall be heavy duty malleable iron or steel industrial service type, with a 180 degree swing.