For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 14.12.090 — Pipe and pipe fittings

Code of Ordinances, City of Westminster, California (eCode360 WE5033 publication; scraped 2026-11-22) · Westminster Code of Ordinances § 14.12.090

Corpus is an independent public-information project, not the official City of Westminster website. Stable reference: corpuslaw.us/code/1e482755-c2dc-482e-87ce-04e1e99c1ad6

§ 14.12.090: Pipe and pipe fittings.

A. All pipe, hose, flexible tubing and fittings, including valves, gauge glass fittings and other similar appurtenances used, or installed or maintained for use, for or in connection with any derrick, production equipment, tank, refinery, natural gasoline plant, commercial dehydration plant, compressor plant, loading rack, bulk distributing station, marine oil terminal or marine oil service station, shall be designed, installed and maintained to withstand the pressure to which they may be subjected with a reasonable factor of safety. Every pipe that is attached to any tank whereby any of the contents of such tank can flow out by gravity shall be provided with a shutoff valve located at or near the tank so that such pipe can be effectively closed from liquids flowing through same and there shall be no branch or connection to any such pipe between any such valve and the tank; except, that there may be installed a small bypass line equipped with a check or non-return valve designed to permit excessive pressure in the pipe to be relieved into the tank. All valves with a diameter of two inches or more and which directly control the flow of any flammable liquid from any tank shall be of the rising stem or indicating type, and shall be marked with a legible mark that will indicate the opened and closed positions. All such valves, gauge glass fittings for tanks and for containers, sample cocks and other similar fittings, intended or used for the purpose of drawing off any flammable liquid from any tank, shall be constructed of some metal having a melting point of not less than eleven hundred degrees Fahrenheit. Gauge glass fittings or pressure tanks shall be equipped with automatic ball checks. B. Any system of piping used for or in connection with any flammable liquid and connected to a positive displacement pump, shall be equipped with automatic pressure relief valve or other means of pressure relief of a type or design approved by the bureau of fire prevention and which will relieve the pressure of any such system and prohibit such pressure from exceeding one hundred twenty-five percent of the normal safe working pressure of such piping system or of such pump, whichever is the lower such pressure. C. The location of all emergency blowoff stacks or automatic or hand-controlled releases of wet gases shall be subject to the approval of the bureau of fire prevention.

( Prior code § 3330.8 )

Ask a question about Westminster law

Corpus searches the Westminster sections it holds and shows the ones that match, with their citations. Free, no sign-in.