§ 17.260.015 — Mixed-Use Zoning District Development Standards
Code of Ordinances, City of Westminster, California (eCode360 WE5033 publication; scraped 2026-11-22) · Westminster Code of Ordinances § 17.260.015
Corpus is an independent public-information project, not the official City of Westminster website. Stable reference: corpuslaw.us/code/7c7e1d10-aa94-4c4b-829e-5f978351af73
§ 17.260.015: Mixed-Use Zoning District Development Standards.
A. General Requirements. Subdivisions and new land uses and structures in the MU zone shall conform to the requirements outlined in Table 2-9, except for single-family residential development, which shall conform to R2 Zoning District Development Standards. In addition, the applicable development standards (e.g., landscaping, parking and loading) outlined in Article 3 of this Title shall apply to all MU zones, unless modified in this Section. Table 2-9Mixed-Use Zoning District Development Standards Development Standard(*See § 17.260.015B for additional provisions.) | MU Zone Minimum lot size | No minimum Minimum residential density | 20 du/acre except for properties in the HO zone which are 30 du/acre Maximum residential density | Site size:Under 2 acres: 50 du/ac2-3 acres: 70 du/ac3+ acres: 90 du/acAdditional residential density may be permitted pursuant to § 17.260.015(C). Maximum building height:* Mixed-use development (residential and nonresidential component) | 6 stories not to exceed 95 feet All other types of development | 6 stories not to exceed 75 feet Maximum nonresidential floor area ratio (FAR) | 1.0 Setbacks:* Front, ground floor* | Minimum: 5 feetMaximum: 15 feet* Front, upper floors | See § 17.260.015B Side, interior lot | None required Side, corner lot | Minimum: 5 feet/Maximum: 15 feet Rear | Minimum: 10 feet Distance b/w buildings on the same lot | Minimum: 10 feet From Garden Grove Boulevard | Minimum additional 20 ft. beyond setback Additional residential standards: Accessory buildings and structures (other than ADUs) | Maximum height: 15 feet to the roof peak, and 10 feet to the highest portion of flat buildings or structuresSee Section 17.400.130 Patio (enclosed or open) and sunshade when attached to dwelling unit | Minimum: 10 feet to rear property lineMinimum: 5 feet to side property lineMinimum 10 feet to street side property line if it is a corner lot Distance between detached accessory structure and main building | Minimum: 6 feetSee Section 17.400.130 Distance between main buildings on the same lot | Minimum: 15 feet Minimum vertical clearance: | 9 feet above pedestrian pathways; 13.5 feet above vehicular travel ways Open space: Multiple-family residential (no nonresidential component) | Private and common open space shall be provided in accordance with Section 17.260.015E. Nonresidential development (no residential component) | A minimum of 20 percent of the site shall be provided as open space, in accordance with Section 17.260.015E. Mixed-use development (residential and nonresidential components) | In accordance with Section 17.260.015E, based on project configuration. Landscaping | As required by Chapter 17.310; a maximum of 20 percent of the landscape requirement may be met through plants on rooftops, porches or in boxes attached to buildings Signs | As required by Chapter 17.330 Storage and loading of recyclable materials | As required by Section 17.300.045 Fences, walls used as fences, latticework screens, hedges, or thick growths of shrubs or trees, and open-mesh wire fences | As required by Section 17.300.030 B. Additional Provisions and Interpretive Standards. 1. Architectural Projections. Architectural features, including but not limited to awnings, entrance porticos, porches, patio walls, stoops, terraces, unenclosed stairs, balconies, eaves, cornices, canopies, entrance overhangs, trellises, signs, chimneys, fireplaces, and other minor architectural design elements, may exceed the maximum building height by up to 10 feet and may encroach up to six feet into a required street setback, provided that such features do not cross property lines or encroach into the public right-of-way. 2. Sidewalk Width and Public Realm Requirements. Where necessary to achieve the minimum sidewalk width required under Section 17.260.020C, Public Realm Standards, a greater front setback than that identified in Table 2-9 shall be required. 3. First-Story Setback Encroachments. Up to 20% of the first-story building frontage may exceed the maximum front setback identified in Table 2-9. 4. Maximum Front Setback Applicability. The maximum front setback shall apply only to buildings or structures that front onto a public street or right-of-way and is intended to maintain a consistent build-to line along the street. The maximum front setback shall not apply to buildings or structures located behind a street-fronting building on the same property. C. Nonresidential Space Development Incentive. 1. Purpose. This subsection establishes a Nonresidential Space Development Incentive intended to encourage the inclusion and long-term viability of nonresidential uses within mixed-use developments by allowing additional residential density when qualifying nonresidential area is provided. 2. Eligibility. A mixed-use development within the MU zone shall be eligible for up to an additional 10 dwelling units per acre above the applicable base maximum residential density, as established in Table 2-9, provided the project incorporates a minimum amount of qualifying nonresidential area in accordance with Subsection C.3. 3. Minimum Nonresidential Area Required. To qualify for the Nonresidential Space Development Incentive, a project shall include on-site nonresidential area meeting or exceeding the following minimums, based on total site size: a. Sites under two acres: minimum 2,500 square feet of nonresidential area. b. Sites between two and three acres: minimum 5,000 square feet of nonresidential area. c. Sites three acres or greater: minimum 7,500 square feet of nonresidential area. 4. Qualifying Nonresidential Uses. a. Qualifying nonresidential area shall consist of active commercial, office, retail, restaurant, service, recreational, artisan, or other employment-generating uses permitted within the MU zone and may include indoor or outdoor areas designed and operated for independent commercial activity accessible to the public. b. Qualifying nonresidential area may include shared, flexible, or rotating commercial spaces, including but not limited to pop-up retail, shared commercial kitchens, food preparation facilities, artisan marketplaces, food truck courts, or similar outdoor or indoor commercial gathering spaces, provided the space is permanently designed and improved to accommodate ongoing independent commercial activity, and is accessible to the public or intended to serve the public. c. The following shall not qualify as nonresidential area for purposes of this subsection: i. Residential amenities or common areas primarily serving residents; ii. Leasing or management offices serving the residential portion of the project; iii. Storage areas, mechanical rooms, parking structures, or loading areas; or iv. Spaces not designed or intended for independent nonresidential occupancy or commercial activity. 5. Design and Location Requirements. The qualifying nonresidential area shall be: a. Integrated into the overall project design; b. Oriented toward a public street or publicly accessible area, unless an alternative configuration is approved through a Development Review application. 6. Timing of Construction. The qualifying nonresidential area shall be constructed concurrently with the residential development unless an alternative phasing plan is approved as part of the Development Review application. D. Mixed-Use Parking Requirements. The following parking standards shall apply to development in the MU zone, except for residential projects subject to State statutes which conflict with and preempt the parking requirements set forth in this section. All other provisions of Chapter 17.320 shall apply. 1. Number of Spaces Required by Use. Table 2-10Mixed-Use Zoning District Minimum Parking Standards Use | Number of Parking Spaces Required Multiple-family residential | 1 or fewer bedrooms: 1.0 spaces per unit2 bedrooms: 1.5 spaces per unit3+ bedrooms: 2.0 spaces per unit Live/work | 3.0 spaces per unit Restaurants and cafes: Freestanding, not part of a retail shopping center (13 or more seats) | 1 space per 200 square feet Offering patron seating (13 or more seats) | 1 space per 300 square feet Take-out, offering 12 or fewer seats | 1 space per 400 square feet Outdoor dining | Less than 25% of gross floor area: no additional parking is required Commercial uses integrated into residential mixed-use developments Retail, service, office, or personal service uses | 1 space per 500 square feet Restaurant or cafe uses (9 or more seats) | 1 space per 400 square feet Restaurant or cafe uses (8 or less seats) | 1 space per 500 square feet Shared commercial space | 1 space per 500 square feet All other land uses | See Section 17.320.020 2. Tandem parking (i.e., one vehicle parked behind another vehicle) is allowed for residential off-street parking so long as tandem spaces are designated for the same unit. Tandem parking is not allowed for nonresidential uses and cannot be shared between residential and nonresidential uses. 3. Nonresidential parking provided as part of a mixed-use development may be shared between uses (i.e., between nonresidential and residential uses and between nonresidential uses) pursuant to a shared parking study, parking agreement, and/or Parking Management Plan as approved by the City of Westminster. All parties to a shared parking arrangement shall enter into a covenant with the City which shall be recorded in the Office of the County Clerk/Recorder. This covenant shall bind this parking arrangement until such time that it can be demonstrated, to the satisfaction of the Director, that other off-street parking has been provided in compliance with the Westminster Municipal Code requirements. 4. Parking spaces serving residential uses shall be conveniently located near the dwelling units they serve, and in no case shall they be more than 300 feet from an entrance to the residential building. 5. If enclosed parking, including parking garages and structures, is provided for residential and nonresidential portions of a mixed-use development, separate areas/levels and entrances should be provided for each use whenever possible, or as otherwise determined pursuant to a shared parking study, parking agreement, and/or Parking Management Plan as approved by the City of Westminster. 6. Loading areas for nonresidential uses shall be located away from residential units and shall be completely screened from view from public streets, adjacent residential uses, and on-site residential uses provided as part of the mixed-use development. Loading areas shall be compatible in architectural design and details with the overall project. The location and design of loading areas shall mitigate nuisances from noise when residential uses might be impacted. E. Mixed-Use Open Space Standards. 1. Multiple-Family Residential Projects. a. A minimum of 40 square feet of private open space per dwelling unit shall be provided for at least 75% of the units. b. The remaining 25% of units may satisfy the open space requirement through common open space, if desired. c. A minimum of 60 square feet of common open space per dwelling unit shall be provided. 2. Nonresidential Projects. A minimum of 20% of the site area shall be provided as open space. Up to 80% of the required open space may consist of decorative hardscape. 3. Mixed-Use Projects. a. Private open space shall be provided consistent with the requirements for multiple-family residential development. b. For horizontal mixed-use developments, required common open space shall be consistent with the greater of the residential or nonresidential open space requirement. c. For vertical mixed-use developments, required common open space shall be consistent with the lesser of the residential or nonresidential open space requirement. 4. Open Space Dimensions. Private open space areas shall have a minimum horizontal dimension of five feet, and common open space areas shall have a minimum horizontal dimension of 10 feet.
( Ord. 2634 , 5/13/2026 )
Ask a question about Westminster law
Corpus searches the Westminster sections it holds and shows the ones that match, with their citations. Free, no sign-in.
