For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.260.020 — Mixed-Use Zoning District Additional Standards

Code of Ordinances, City of Westminster, California (eCode360 WE5033 publication; scraped 2026-11-22) · Westminster Code of Ordinances § 17.260.020

Corpus is an independent public-information project, not the official City of Westminster website. Stable reference: corpuslaw.us/code/d68c614d-8eaf-4f75-b4de-0747c81b0f40

§ 17.260.020: Mixed-Use Zoning District Additional Standards.

A. Design Guidelines. 1. Development within the MU zone shall be designed in accordance with the applicable Westminster Design Guidelines Manual. 2. For mixed-use development projects which are not governed by the Civic Center Area Design Guidelines, or the Little Saigon Area Design Guidelines, the Commercial Design Guidelines shall apply to the overall site and building design, including ground-floor nonresidential components, and shall be used to implement the General Plan's vision for mixed-use areas. Residential Design Guidelines shall apply to residential components of the project, as applicable. 3. Where there is a conflict between the Westminster Design Guidelines Manual and the standards contained in this Chapter, the standards of Chapter 17.260 shall prevail. B. Building Design and Articulation Standards. The following building design and articulation standards shall apply in addition to the general development standards included in Table 2-9. 1. Rooflines. Rooflines, whether pitched or flat, shall be vertically articulated at least every 50 feet, using architectural elements such as parapets, varying cornices, reveals, clerestory windows, and varying roof height and/or form. 2. Screening. The screening and separation of adjoining residential uses, equipment, trash enclosures, accessory outdoor storage areas (i.e., storage for maintenance or landscaping supplies), and surface-parking areas from adjoining residential development shall be provided in accordance with Section 17.300.035 of this Title. See Subsection E below for additional refuse and recyclable materials storage requirements. 3. Corner Buildings. All corner buildings shall: a. Incorporate visually interesting architectural elements such as towers, cornice features, roof shapes, or roofline variation. b. Be oriented toward the primary intersection and the primary and secondary street frontages, while parking and auto access shall be located away from the primary intersection corners. 4. Massing Relief for Multistory Buildings. All multistory buildings in the MU zone must incorporate at least one of the following building massing relief features: a. Upper floor change in wall plane of at least four feet in depth (either recess or projection) for at least 30% of the front façade length. See Figure 2-1; or b. A vertical façade break for all floors with a minimum depth of six feet for a minimum of 15% of the front façade length. Non-recessed building walls shall not exceed a width of 50 feet. See Figure 2-2. 5. Additional Massing Relief for Buildings Four Stories or More. In addition to features required for all multistory buildings in Subsection B.4 above, buildings four stories or more must also incorporate at least one of the following additional features: a. From the fourth story and above, a recessed stepback facing the primary street of at least four feet for the entire façade length. See Figure 2-3. Recessed area may be used as a balcony, terrace, or other usable open space. b. From the fourth story and above, a recessed stepback facing the primary street of at least 10 feet for a minimum of 35% of the façade length. See Figure 2-4. Recessed area may be used as a balcony, terrace, or other usable open space. c. Other alternative comparable method, as determined by the review authority through the development review process, to break down the massing of large building façades and complement the surrounding context. Figure 2-1: Upper Floor Change [image] Figure 2-2: Vertical Façade Break [image] Figure 2-3: Upper Story Stepback (Entire Façade Length) [image] Figure 2-4: Upper Story Stepback (Partial Façade Length) [image] C. Public Realm Standards. The public realm in MU zone consists of three areas: the frontage area, pedestrian area, and vehicular area. See Figure 2-5. The following public realm standards shall apply in addition to the general development standards included in Table 2-9 and in Subsection B above. 1. Frontage Area. The frontage area consists of the area between the primary building façade and the sidewalk. The frontage area is located on private property. The following frontage area standards apply to development in the MU zone: a. The frontage area along commercial or mixed-use frontages shall be an extension of the sidewalk, landscaped, used for outdoor dining space, or used for other purposes that enhance the pedestrian environment. The frontage area along buildings without doors or windows shall be enhanced with at least two pedestrian amenities for every 30 feet of frontage (e.g., potted plants, bench seating, or other pedestrian amenities). b. The frontage area along residential frontages shall provide pathways connecting the sidewalk to the front door and to any parking areas, and shall otherwise be landscaped across the entire property frontage, with the exception of a pedestrian walkway, as described in Subsection C.2. c. Ground floor retail storefronts shall provide a minimum of 60% of the front façade area as open exposure to the street through the use of windows, doors, and other openings in order to allow views of indoor space. Windows shall be transparent; opaque or reflective glazing is not permitted. For corner buildings, this requirement shall apply to both street-facing sides. See Figure 2-6. 2. Pedestrian Area. The pedestrian area consists of the pedestrian walkway and an additional area adjacent to the curb for trees, planters, lighting, and other pedestrian amenities. This area is typically located in the public right-of-way. The following pedestrian area standards apply to development in the MU zone, as shown in Figure 2-7. a. Public sidewalks abutting a development parcel shall have a minimum sidewalk width of at least 10 feet as measured curb face. b. A minimum six-foot clear and unobstructed path shall be provided in the pedestrian area to accommodate pedestrian movement. c. The pedestrian area shall contain at least one irrigated curbside street tree for every 40 linear feet of sidewalk and shall comply with requirements set in Chapter 12.12 (Street Forestry Policy). d. Curbside sidewalk tree wells shall be between four and six feet in width. e. Landscape and street lighting shall be located within a minimum four-foot wide area adjacent to the back of curb. f. If the existing public right-of-way area between the curb and the property line is insufficient to meet the minimum standards above, extension of the sidewalk onto the property, with corresponding dedication, shall be provided. 3. Vehicular Area. The vehicular area consists of vehicular travel lanes and may include bike lanes and parking lanes. The vehicular area is located in the public right-of-way. The following vehicular area standards apply to development in the MU zone: a. Development shall implement the Mobility Element of the City of Westminster General Plan. Figure 2-5: Public Realm Standards [image] Figure 2-6: Open Exposure (Transparency) Standards [image] Figure 2-7: Pedestrian Area Standards [image] D. Public Art Requirement. 1. Purpose. The purpose of this requirement is to encourage incorporation of public art into mixed-use development in a manner that contributes to the public realm and community identity. 2. Applicability. Development projects within the MU zone that require Development Review approval shall incorporate a public art element as part of the project design. 3. Exemptions. The public art requirement shall not apply to: a. Residential projects consisting of nine dwelling units or fewer; or b. Nonresidential projects that add less than 10,000 square feet of new building floor area. 4. Public art required pursuant to this Section shall comply with all of the following: a. Integration. The public art shall be permanently integrated into the project site or building design. b. Visibility. The public art shall be clearly visible from a public street, sidewalk, or publicly accessible area. c. Minimum Size. The public art shall meet the following minimum size requirements: i. Wall-mounted or façade-integrated art, including murals or similar installations, shall have a minimum surface area of 150 square feet. For development sites with more than 1,000 linear feet of street frontage, the required minimum surface area shall be increased to at least 300 square feet, which may be provided as a single installation or as multiple coordinated installations distributed along the street frontage. ii. Ground-mounted or freestanding art, including sculptures, decorative fountains, decorative seating or benches, or water features, shall occupy a minimum footprint of 50 square feet. d. Exclusions. Decorative architectural finishes, supergraphics, branding elements, logos, signage, or sign copy regulated under this Title shall not be considered public art for purposes of this Section, regardless of size, color, or artistic treatment. E. Refuse, Organic, and Recyclable Materials Storage Requirements. In addition to requirements set in Section 17.300.045, the following shall apply to all MU zones: 1. Refuse, organic, and recycling enclosures for nonresidential uses shall be located away from residential units and shall be completely screened from view from the residential portion of the project, from public streets, and from adjacent residential uses. 2. The location and design of refuse, organic, and recycling enclosures shall mitigate nuisances from noise and odors. F. Undergrounding of Utilities. All utilities, including telephone, cable television, and electric systems, required within the limits of all MU zones shall be located underground. The undergrounding of utilities shall apply to any new building or structure constructed on a parcel of land or when substantial reconstruction of an existing building or structure results in an addition exceeding 50% of the total square footage of the existing building or structure. G. Live/Work Use Standards. The following standards shall apply to live/work development. All other provisions of Article 3 of this Title shall apply. 1. The minimum square footage of a live/work unit shall be 1,000 square feet. 2. All living space within the live/work unit shall be contiguous with, and an integral part of, the working space, with direct access between the two areas. 3. At least one of the workers of the live/work unit shall reside in the unit. The residential area shall not be rented separately from the working space. The business activity occupying the live/work unit may have employees in addition to residents, as necessary. 4. Complete kitchen space and sanitary facilities shall be provided for each unit in compliance with all applicable codes. 5. The nonresidential ground floor portion of the unit shall comprise no less than one-third of the ground floor space, not including stairwells. 6. All work activities and workspace shall be limited to the first floor. 7. The nonresidential component of a live/work unit shall only be a nonresidential use allowed within the MU zone. 8. All activities related to the "work" component of the live/work unit shall be conducted within the interior of the same live/work unit. 9. Retail space may be integrated with working space. 10. A live/work unit shall be used for both residential and nonresidential purposes; use of a live/work unit exclusively for nonresidential use is prohibited. 11. A business license shall be obtained in compliance with the WMC for business activities conducted within the live/work unit. 12. The ground floor of the live/work unit shall provide a minimum 40% open exposure to the street through the use of windows, doors, and other openings in order to allow views of indoor space. Windows shall be transparent; opaque or reflective glazing is not permitted. 13. Signage shall be a maximum of three square feet; illumination is prohibited.

( Ord. 2634 , 5/13/2026 )

Ask a question about Westminster law

Corpus searches the Westminster sections it holds and shows the ones that match, with their citations. Free, no sign-in.