For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 4-1-2-7 — Flood fringe sub-zone standards

Code of Ordinances of the City of Arvada, Colorado (Supp. No. 67: codified through Ordinance No. 4932, enacted May 5, 2026) · Arvada Land Development Code, art. 4-1, § 4-1-2-7

Corpus is an independent public-information project, not the official City of Arvada website. Stable reference: corpuslaw.us/code/68d2c04b-0b70-405b-afd0-b912f2af8930

4-1-2-7. - Flood fringe sub-zone standards.

A. Generally. The Flood Fringe Sub-Zone represents the area that is inundated in the 100-year flood that may serve as a temporary storage area for the flood waters and is the area that lies landward of the floodway. B. Special Provisions. 1. No fill, structure, deposit, or other floodplain uses are permitted in the flood fringe sub-zone that adversely affect the efficiency of any channels or floodways of any tributaries to the main stream or river; drainage ditches; or any other drainage facilities or systems. Tents and other makeshift structures, enclosures, or other similar shelters used for human habitation are also prohibited in the flood fringe sub-zone. 2. If a property has been issued a LOMR-F and the property has been filled so as to remove it from the floodplain, no building permit shall be issued for a new structure to be constructed that would result in a finished floor elevation, including the basement, below the previously existing base flood elevation. 3. Residential Construction. New construction and substantial improvement of any residential structure within or moved into the Regulatory Floodplain shall have the lowest floor (including the basement and any mechanical equipment or attendant utilities) constructed at or above the flood protection elevation of two feet above the base flood elevation. If such new construction or substantial improvement of a residential structure is within Flood Zone AO, then the lowest floor of the residential structure (including the basement and any mechanical equipment or attendant utilities) must be constructed at or above a point two feet above the depth number specified in feet on the DFIRM, and the depth number shall be at least two feet if it is not specified on the DFIRM. For new construction and substantial improvements of residential structures within Zones AH and AO in the Regulatory Floodplain, adequate drainage paths shall be constructed all around the structures on slopes to guide flood waters around and away from the structures. If neither base flood elevation nor depth number is available, the flood protection elevation shall be at least four feet above the highest adjacent grade. 4. Nonresidential Construction. New construction and substantial improvements of any commercial, industrial, or other non-residential structure within or moved into the Regulatory Floodplain shall either: a. Have the lowest floor (including basement and any mechanical equipment or attendant utilities) constructed at or above the flood protection elevation of one foot above the base flood elevation, or at or above a point one foot above the depth number if within Flood Zone AO, and as specified in feet on the DFIRM (the depth number shall be at least two feet if it is not specified on the maps). If neither base flood elevation nor depth number is available, the flood protection elevation shall be at least three feet above the highest adjacent grade; or b. Together with attendant utility and sanitary facilities shall: i. Be flood-proofed to or above the flood protection elevation, such that the structure is watertight with walls substantially impermeable to the passage of water; ii. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and iii. Be certified by a Colorado registered professional engineer that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions of this paragraph. Such certifications shall be provided to the Floodplain Administrator as set forth in subsection 8-1-1-4. c. For non residential construction within Zones AH and AO in the Regulatory Floodplain, adequate drainage paths shall be constructed all around structures on slopes to guide flood waters around and away from the structures. 5. Manufactured Homes. Manufactured homes shall be anchored in accordance with Section 4-1-2-6(B), Anchoring. a. All manufactured homes that are placed or substantially improved on a site in Zones A1-30, AH, or AE on the DFIRM shall be elevated on a permanent foundation such that the lowest floor of the manufactured home, together with mechanical equipment and attendant utilities, is constructed at or above a point two feet above the base flood elevation, and shall be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement, if the manufactured home is: i. Outside of a manufactured home park or subdivision; ii. In a new manufactured home park or subdivision; iii. In an expansion to an existing manufactured home park or subdivision; or iv. In an existing manufactured home park or subdivision on which a manufactured home has incurred "substantial damage" as the result of a flood. b. All manufactured homes that are placed or substantially improved on sites in existing manufactured home parks or subdivisions that are not subject to the provisions in subsection (a) above, shall be elevated so that either: i. The lowest floor of the manufactured home, together with mechanical equipment and attendant utilities, is constructed at or above a point two feet above the base flood elevation; or ii. The manufactured home chassis is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than 36 inches in height above grade and are securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement of the foundation from hydrostatic and hydrodynamic loads, including buoyancy. c. Any manufactured home park or manufactured home subdivision within the limits of the Regulatory Floodplain shall file an evacuation plan with the appropriate disaster preparedness authority indicating alternate vehicular access and escape routes. 6. Recreational Vehicles. a. A recreational vehicle ("RV") is a vehicle which is: i. Built on a single chassis; ii. 400 square feet or less when measured at the largest horizontal projection; iii. Designed to be self-propelled or permanently towable by a light duty truck; and iv. Designed primarily not for use as a permanent dwelling but as a temporary living quarters for recreational, camping, travel, or seasonal use. b. All RVs shall either: i. Be on the site for fewer than 180 consecutive days; ii. Be fully licensed and ready for highway use (meaning the RV is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities, and has no permanently attached additions); or iii. Meet the permit requirements and elevation and anchoring requirements for a manufactured home for resisting flotation, collapse, and lateral movement from hydrostatic and hydrodynamic loads, including buoyancy. 7. Critical Facilities. New construction and substantial improvements of any facility classified as a critical facility within or moved into the Regulatory Floodplain shall have the lowest floor (including basement and any mechanical equipment or attendant utilities) constructed at or above a point two feet above the base flood elevation. New critical facilities shall, when practicable as determined by the Floodplain Administrator, have continuous non-inundated access (ingress and egress for evacuation and emergency services) during a 100-year flood event. 8. Materials Storage and Processing. The storage or processing of materials that are buoyant, flammable, explosive, or in times of flooding could be injurious to human, animal, or plant life, shall be at or above a point two feet above the base flood elevation for a particular area, or adequately flood-proofed in accordance with provisions in this Division. 9. Approvals. Building plans for all projects or construction, regardless of the type of structure, that will be placed, altered, or constructed within the Flood Fringe Sub-Zone must be submitted to the Floodplain Administrator, for approval, in accordance with Section 8-3-5-6, Floodplain Development Permit, to ensure that said project or construction will not adversely affect the Regulatory Floodplain and is in compliance with the requirements of this code pertaining to the Regulatory Floodplain. 10. Anchoring. Any structure permitted in the Flood Fringe Sub-Zone pursuant to this Section shall be firmly anchored to prevent the structure or building from floating away and thus threatening to restrict bridge openings and other restricted sections of the stream or river. C. Permitted Uses. Any uses permitted by the underlying zoning district, in conformance with the provisions in the above subsection (B), may be permitted by the Floodplain Administrator, subject to the following conditions: 1. If the Floodplain Administrator disallows a requested use through a Floodplain Development Permit that is permitted in the underlying zoning district, and that is in conformance with the provisions in the above subsection (B), the Applicant may follow the procedures outlined in Section 8-3-11-6 Floodplain Variance, or Section 8-2-5, Administrative Appeals. 2. The Floodplain Administrator may also require the Applicant to follow the procedure outlined in Section 8-3-5-6, Floodplain Development Permit for certain uses in the Flood Fringe Sub-Zone, when said action appears to be in the public interest, and where the health, safety, and welfare of the public may be in question. D. Watercourse. In riverine situations, adjacent communities and the state coordinating agency, which is the Colorado Water Conservation Board, should be notified prior to any alteration or relocation of a watercourse, and submit evidence of such notification to FEMA in order to ensure that the flood carrying capacity within the altered or relocated portion of any watercourse is maintained. The applicant is responsible for submitting such notification.

(Ord. No. 4867, § 2, 2-12-2024)

Ask a question about Arvada law

Corpus searches the Arvada sections it holds and shows the ones that match, with their citations. Free, no sign-in.