9-14-32. - Building Facade Elements.

(a) Windows. Windows on all buildings shall be constructed consistent with the following requirements: (1) Amount. Each building shall meet the transparency requirements applicable to the building type pursuant to Sections 9-14-16 through 9-14-21, B.R.C. 1981. (2) Recessed. All windows, with the exception of ground story storefront systems, shall be recessed with the glass a minimum of two inches back from the facade surface material or adjacent trim. (3) Vertically Oriented. All windows on Type A, B, and C frontage facades shall be vertically oriented unless the following standards are met: (A) Upper Stories. Horizontally oriented windows may be used for up to thirty percent of the total transparency area of each upper story. (B) Window and Height Location. Horizontally oriented windows may be used if the height of at least seventy-five percent of the windows is a minimum of five feet, and the windows are located no more than three feet above the interior floor level. (4) Visibility Through Glass. Reflective glass is prohibited on Type A, B, and C frontage facades. Windows shall meet the transmittance and reflectance factors established in the transparency definition of Section 9-14-8 "Definitions," B.R.C. 1981. (5) Expressed Lintels. Lintels shall be expressed above all windows and doors by a change in brick coursing or by a separate element. See Figure 14-63. Vertically Oriented Windows with Expressed Lintels.

![Figure 15-63. Vertically Oriented Windows with Expressed Lintels](https://figures.74-208-44-221.nip.io/boulder/496676/6c1b7035d54cb1260cc4daa3086406921a2e51f4f20bb70887dbf8dbf4c9449c.png)

Figure 15-63. Vertically Oriented Windows with Expressed Lintels (b) Awnings, Canopies, & Light Shelves. On Type A, B, and C frontage facades, awnings, canopies, and light shelves shall be constructed consistent with the requirements of this subsection. See Figure 14-64. Examples of Permitted Awnings. (1) Encroachment. Awnings, canopies, and light shelves shall not extend into a city right-of-way or easement except consistent with the requirements of Section 8-6-6, "Requirements for Revocable Permits, Short-Term Leases and Long-Term Leases," B.R.C. 1981. (2) Attached Awnings & Canopies. Awnings and canopies that are attached to the building and could be removed shall meet the following standards: (A) Material. Plastic awnings are prohibited. (B) Solar Panels. Solar awnings or canopies are allowed. (C) Lighting. Backlit awnings are prohibited. (D) Structures. Support poles are prohibited unless utilized for outdoor eating areas over eight feet in depth. (E) Multiple Awnings on the Facade. When more than one awning is mounted on a facade, the awning types and colors shall be coordinated by matching the color, shape, material, or other element. (3) Canopies & Light Shelves. Permanent canopies, projections, or overhangs used as architectural features, light shelves, or shading devices are permitted, subject to materials standards of Section 9-14-28, "Facade Materials," B.R.C. 1981. (4) Clearance. All portions of any awning, canopy, or light shelf shall provide at least eight feet of clearance over any walkway and shall not extend over any driveway.

![Figure 14-64. Examples of Permitted Awnings](https://figures.74-208-44-221.nip.io/boulder/496676/a3156131a89cda3d2308d0d9c40196edc608f424c39ff9bdde6851713727dbf6.png)

Figure 14-64. Examples of Permitted Awnings (c) Balconies. On a Type A frontage facade, any balconies shall meet the requirements of this subsection (c), and false balconies are prohibited. On Type B and Type C frontage facades, any balconies shall meet the requirements of this subsection (c) or be false balconies. See Figure 14-65. Examples of Balconies. (1) Balcony Requirements. Balconies shall meet the following: (A) Definition. For the purpose of this subsection (c), balconies shall include any roofed or unroofed platform that projects from the wall of a building above grade and is enclosed only by a parapet or railing. (B) Size. Balconies shall be a minimum of four feet deep and five feet wide. (C) Integrated Design. The balcony shall be designed to be integrated with the building facade through techniques that may include, without limitation, structural integration, minimal protrusion, facade articulation, material consistency, and color consistency. Separate columns or posts supporting any balcony from the ground are prohibited. (D) No Drip-through Decks. Drip-through decks are prohibited. (E) Platform. The balcony platform shall be at least three inches thick. Any underside of a balcony that is visible from any public way shall be finished. (F) Facade Coverage. No more than forty percent of Type A and Type B frontage facades, calculated separately for each facade, may be covered by balconies. The balcony area is calculated by drawing a rectangle around the platform or floor of the balcony, any columns or indentations, and any ceiling, roof, or upper balcony. (2) False Balconies. False balconies consist of a rail and door, and any outdoor platform less than eighteen inches in depth. The requirements of paragraph (1) of this subsection (c) do not apply to false balconies.

![Figure 14-65. Examples of Balconies](https://figures.74-208-44-221.nip.io/boulder/496676/e133c36281269445e90cca12f67c5691478da00b984d91b43937a0b765ef6271.png)

Figure 14-65. Examples of Balconies (d) Shutters. If included in the design, shutters, whether functional or not, shall meet the following requirements: (1) Size. All shutters shall be sized for the windows, so that, if the shutters were to be closed, they would not be too small for complete coverage of the window. (2) Materials. Shutters shall be wood, metal, fiber cement, composite wood, or high-pressure laminate (HPL). Vinyl shutters are prohibited. Other "engineered" materials may be approved provided that the applicant submits a sample and examples of high quality, local installations of the material, installed a minimum of five years earlier and showing no degradation or wear of the material. (e) Principal Entryway. See Figure 14-66. Examples of Defined Principal Entryway. Principal entrances to buildings or units, with the exception of ground story storefront systems, are subject to the following: (1) Principal entrances shall be clearly delineated through at least two of the following design features: (A) Cap or Canopy. The entryway is covered by a cap or canopy differentiating it from the overall building cap. (B) Porch. The entryway is through a porch. (C) Sidelights and Transom. Sidelights or transom windows are included around the entryway. (D) Lighting Feature. The entrance is lit with a sculptural lighting feature or other unique lighting system visible during daylight. (E) Sculpture or Mural. The entryway is defined by a special art feature, either a sculpture or mural. (F) Extended Articulation. The entryway is included in a separate bay of the building that extends up at least two stories. (2) Other Design. The approving authority may approve a design that does not meet the standards of this subsection if the authority finds that the design adds emphasis and draws attention to the entryway. (3) Right-of-Way. Doors shall not swing into city right-of-way or easement.

![Figure 14-66. Examples of Defined Principal Entryway](https://figures.74-208-44-221.nip.io/boulder/496676/21e274e95b4c8219ba09df9737f599fe9a99f6322749a6bf43f03689ecbbdcc9.png)

Figure 14-66. Examples of Defined Principal Entryway Ordinance No. 8669 (2025)