For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 13-42-060 — Design criteria

Municipal Code of the City and County of Broomfield, Colorado (Codified through Ordinance No. 2304, adopted May 26, 2026 (Supp. No. 54)) · Broomfield Municipal Code § 13-42-060

Corpus is an independent public-information project, not the official City of Broomfield website. Stable reference: corpuslaw.us/code/d9c3dfca-2149-4fcf-be41-95bea071aa0c

13-42-060 - Design criteria.

(A) Design criteria for all graywater treatment works. The following minimum design criteria are required for all graywater treatment works. All graywater treatment works must: (1) Meet all design requirements of this regulation and meet any additional design requirements of the Colorado Plumbing Code. (2) Each treatment component or combination of multiple components must have a design flow greater than the calculated peak graywater production, if upstream of the storage tank or if no tank is present. (3) Include a diversion valve that directs graywater to either the graywater treatment works or a closed sewerage system. The diversion valve must be: a. Easily operable; b. Clearly labeled; c. Constructed of material that is durable, corrosion resistant, watertight; d. Designed to accommodate the inlet and outlet pipes in a secure and watertight manner; and e. Indirectly connect the bypass line to the closed sewerage system. (4) Not have any piping that allows the treatment process(es) or a storage tank to be bypassed prior to graywater use. (5) Include a tank to collect and store graywater, except for a subsurface irrigation system that discharges to a mulch basin. The storage tank must: a. Be constructed of durable, non-absorbent, water-tight, and corrosion resistant materials; b. Be closed and have access openings for inspection and cleaning; c. Be vented: 1. For indoor tanks: the tanks must be vented to the atmosphere outside of the house; 2. For outdoor tanks: the storage tank must have a downturned screened vent; d. Have an overflow line: 1. With the same or larger diameter line as the influent line; 2. Without a shut off valve; 3. that is trapped to prevent the escape of gas vapors from the tank; and 4. that is indirectly connected to the closed sewerage system; e. Have a valved drain line with the same or larger diameter line as the influent line that is indirectly connected to the closed sewerage system; f. Be a minimum of fifty gallons; g. Be placed on a stable foundation; h. If located outdoors, not be exposed to direct sunlight; and i. Have a permanent label that states "CAUTION! NON-POTABLE WATER. DO NOT DRINK." (6) For indoor toilet or urinal flushing systems (categories C and D) graywater treatment works must have a backup potable water system connection. For subsurface irrigation systems (categories A and B) graywater treatment works may, but are not required to, have a backup potable water system that provides potable irrigation water when graywater is not being produced or is produced in insufficient quantities. A backup potable water system connection must meet the following requirements: a. For non-public water system, potable water system connections: uncontrolled cross connections between a potable water system and a graywater treatment works are prohibited. All cross connections must be protected by a reduced pressure principle backflow prevention zone assembly or an approved air gap. b. For public water system, potable water system connections: uncontrolled cross connections between a public water system and a graywater treatment works are prohibited. The graywater treatment works design must protect the public water system from cross connections by meeting the requirements of 5 CCR 1002-11: Colorado Primary Drinking Water Regulations. (7) Not be used as a factor to reduce the design, capacity, or soil treatment area requirements for OWTS or domestic wastewater treatment works. (8) Have any wastewater from graywater treatment works (e.g., filter backwash water) be properly contained and disposed into a closed sewerage system or an approved underground injection control ("UIC") well. (9) Have all graywater piping clearly distinguished and must be clearly labeled, including pipe identification and flow arrows. (10) If located in a 100-year floodplain area, meet or exceed the requirements of FEMA and the local emergency agency. The graywater system must be designed to minimize or eliminate infiltration of floodwaters into the system and prevent discharge from the system into the floodwaters. (11) Not be located in floodways. (12) Be located within the confines of the legal property boundary and not within an easement. (B) Design criteria for subsurface irrigation systems. (1) The following minimum design criteria are required for all graywater treatment works being used for subsurface irrigation. All subsurface graywater irrigation systems must: a. Have the subsurface irrigation components of the graywater irrigation system installed a minimum of four inches and a maximum of twelve inches (below the finished grade. b. Have the subsurface irrigation components of the graywater irrigation system installed in suitable soil, as defined in section 5 CCR 1002-86.8(36). c. Have a minimum of twenty-four inches of suitable soil between the subsurface irrigation components of the graywater irrigation system and any restrictive soil layer, bedrock, concrete, or the highest water table. Restrictive soil layers are soil types 4, 4A, and 5 in Table 3. d. Include controls, such as valves, switches, timers, and other controllers, as appropriate, to ensure the distribution of graywater throughout the entire irrigation zone. e. If utilizing emitters, the emitters must be designed to resist root intrusion and be of a design recommended by the manufacturer for the intended graywater flow and use. Minimum spacing between emitters shall be sufficient to deliver graywater at an agronomic rate and to prevent surfacing or runoff. f. Have all irrigation supply lines be polyethylene tubing or PVC Class 200 pipe or better and Schedule 40 fittings. All joints shall be pressure tested at 40 psi (276 kPa), and shown to be drip tight for five minutes before burial. Drip feeder lines can be poly or flexible PVC tubing. g. Meet the following setback distances in Table 12-1 in 5 CCR 1002-86. Table 2. Graywater System Setback Requirements Minimum Horizontal Distance Required from: | Graywater Storage Tank | Irrigation Field Buildings | 5 feet | 2 feet Property line adjoining private property | 10 feet | 10 feet Property line adjoining private property with supporting property line survey | 1.5 feet | 1.5 feet Water supply wells | 50 feet | 100 feet Streams and lakes | 50 feet | 50 feet Seepage pits or cesspools | 5 feet | 5 feet OWTS disposal field | 5 feet | 25 feet OWTS tank | 5 feet | 10 feet Domestic potable water service line | 10 feet | 10 feet Public water main | 10 feet | 10 feet h. The irrigation field must be located on slopes of less than thirty percent from horizontal. i. Protocols for determining the size of the subsurface irrigation area. The irrigation area must be determined using one of the following protocols: 1. Site evaluation protocol: The following site evaluation must be conducted to determine the appropriate size of the irrigation area for all subsurface irrigation systems, except single family dispersed subsurface irrigation systems (category A and C dispersed subsurface irrigation systems) that are sized using the irrigation area equation protocol as defined in in 5 CCR 1002-86.12(B)(1)(i)(ii). The site evaluation must include: i. Site information, including: (a) a site map; and (b) location of proposed graywater irrigation area in relation to physical features requiring setbacks in Table 2. ii. Soil investigation to determine long-term acceptance rate of a graywater irrigation area as a design basis. Soil investigation must be completed by either: (a) A visual and tactile evaluation of soil profile test pit; or (b) A percolation test. iii. Irrigation rates must not exceed maximum allowable soil loading rates in Table 3 based on the finest textured soil in the twenty-four inches of suitable soil beneath the subsurface irrigation components. Table 3. Soil Type Description and Maximum Hydraulic Loading Rate Soil Type | USDA Soil Texture | USDA Structure - Shape | USDA Soil Structure-Grade | Percolation Rate (MPI) | Loading Rate for Graywater (gal./sq. ft./day) 0 | Soil Type 1 with more than 35% Rock (>2mm); Soil Types 2-5 with more than 50% Rock (>2mm) | — | 0 (Single Grain) | Less than 5 | Not suitable without augmentation 1.0 with augmentation 1 | Sand, Loamy Sand | — | 0 | 5-15 | Not suitable without augmentation 1.0 with augmentation 2 | Sandy Loam, Loam, Silt Loam | PR BK GR | 2 (Moderate) 3 (Strong) | 16-25 | 0.8 2A | Sandy Loam, Loam, Silt Loam | PR, BK, GR 0 (none) | 1 (Weak) Massive | 26-40 | 0.6 3 | Sandy Clay Loam, Clay Loam, Silty Clay Loam | PR, BK, GR | 2, 3 | 41-60 | 0.4 3A | Sandy Clay Loam, Clay Loam, Silty Clay Loam | PR, BK, GR 0 | 1 Massive | 61-75 | 0.2 4 | Sandy Clay, Clay, Silty Clay | PR, BK, GR | 2, 3 | 76-90 | Not suitable 4A | Sandy Clay, Clay, Silty Clay | PR, BK, GR 0 | 1 Massive | 91-120 | Not suitable 5 | Soil Types 2-4A | Platy | 1, 2, 3 | 121+ | Not suitable iv. Suitable soil may consist of original, undisturbed soil or original soil that is augmented. Not suitable soil may be augmented as needed to ensure suitable soil is used. v. If the original soil is augmented, the mixture used for augmentation must meet the following criteria to ensure that suitable soil is achieved: (a) The mixture must have an organic content that is at least five percent and no greater than ten percent; (b) The mixture must be a well-blended mix of mineral aggregate (soil) and compost where the soil ratio depends on the requirements for the plant species; and (c) The mineral aggregate must have the following gradation: Sieve Size | Percent Passing 3/8 | 100 No. 4 | 95 - 100 No. 10 | 75 - 90 No. 40 | 25 - 40 No. 100 | 4 - 10 No. 200 | 2 - 5 vi. If the original soil is augmented, the additional soil must be tilled into the native soil a minimum of six inches below irrigation application zone. vii. Soil types 0 and 1 must be augmented before use. Soil type 4, 4A, and 5 are not suitable for subsurface irrigation. 2. Irrigation area equation protocol: The following irrigation area equation protocol may be used to determine the appropriate size of the irrigation area for single family, dispersed subsurface irrigation systems (categories A and C dispersed subsurface irrigation systems). This protocol cannot be used to size mulch basins. LA = GW / (CF x ET x PF) Where: LA = Landscaped area (square feet); GW = Estimated graywater flow (gallons per week); CF = 0.62 (square foot x inch / gallon) = (7.48 gallons / 1-cu-ft) / 12 inch/ft); ET = Evapotranspiration rate (inch / week), as determined by USDA Natural Resources Conservation Service CO652.0408 "Figure CO4- 1: Map of Colorado Climate Zones" dated April 1978, or weekly averages based on actual conditions; PF = Plant factor, 0.5. (2) Mulch basin irrigation system requirements. The following minimum design criteria are required for graywater treatment works using mulch basin systems for subsurface irrigation: a. Mulch shall be permeable enough to allow rapid infiltration of graywater. b. The minimum void space mulch basin volume must be either: 1. Three times the anticipated average daily flow for graywater treatment works without a storage tank to allow for graywater volume surges and to prevent surfacing or runoff. 2. One and a half (1.5) times the anticipated average daily flow for graywater treatment works with storage tank meeting the 5 CCR 1002-86.11(Ag)(5) design criteria. c. Piping to mulch basins must discharge a minimum of four inches below grade into a container for dispersal of graywater into the mulch basin. The container must be designed to have four inches of freefall between the invert of the discharge pipe and the mulch. The container must have an access lid for observation of flow and to check mulch levels. d. The mulch basin must have a minimum depth of twelve inches below grade and not more than twenty-four inches below grade. e. A filter is not required. (3) Dispersed subsurface irrigation system requirements. The following minimum design criteria are required for graywater treatment works using dispersed irrigation systems for subsurface irrigation: a. Include a cartridge filter, which must meet the following requirements: 1. A minimum of sixty mesh; 2. Located between the storage tank and the irrigation system; 3. If a pump is being used to pressurize the graywater distribution system, the filter must be located after the pump. (C) Design criteria for indoor toilet and urinal flushing graywater treatment works (categories C and D). (1) Category C: single family, indoor toilet and urinal flushing graywater treatment works The following minimum design criteria are required for graywater treatment works for category C: single family, indoor toilet, and urinal flushing: a. The graywater treatment works must be certified under "Class R" of NSF/ANSI 350 Onsite Residential and Commercial Water Reuse Treatment Systems. b. If a disinfection process is not part of NSF/ANSI 350-2011 equipment, separate disinfection system equipment is required. For graywater treatment works that use sodium hypochlorite (bleach), the graywater treatment works must be capable of providing a free chlorine residual of 0.2 to 4.0 mg/L in the graywater throughout the indoor graywater plumbing system. c. The graywater treatment works must include a dye injection system that is capable of providing a dye concentration that is visibly distinct from potable water. d. For category C indoor toilet and urinal flushing graywater treatment works that are also capable of using graywater for subsurface irrigation, the system may be designed to allow graywater to be diverted to the subsurface irrigation graywater treatment works prior to the disinfection and dye process, however after the point of diversion the subsurface irrigation portion of the system must meet the requirements in in 5 CCR 1002-86.12(B). (2) Category D: non-single family, indoor toilet and urinal flushing graywater treatment works, The following minimum design criteria are required for category D: non-single family, indoor toilet and urinal flushing: a. The graywater treatment works must be certified under "Class R" or "Class C" of NSF/ANSI 350 Onsite Residential and Commercial Water Reuse Treatment Systems. Required classification shall be dictated by the size of the graywater treatment works and if the graywater sources are residential or commercial as defined by NSF/ANSI 350. b. Separate disinfection system equipment is required if a disinfection process is not part of NSF/ANSI 350-2011 equipment. A graywater treatment works must be capable of providing a free chlorine residual of 0.2 to 4.0 mg/L in the graywater throughout the indoor graywater plumbing system. c. The graywater treatment works must include a dye injection system that is capable of providing a dye concentration that is visibly distinct from potable water. d. For category D indoor toilet and urinal flushing graywater treatment works that are also capable of using graywater for subsurface irrigation, the system may be designed to allow graywater to be diverted to the subsurface irrigation graywater treatment works prior to the disinfection and dye process, however after the point of diversion the subsurface irrigation portion of the system must meet the requirements in 5 CCR 1002- 86.12(B). e. For graywater treatment works that have a capacity to receive greater than 2,000 gallons per day, the design must be prepared under the supervision of and submitted with the seal and signature of a professional engineer licensed to practice engineering in the State of Colorado in accordance with the requirements of the Colorado Department of Regulatory Agencies (DORA) - Division of Registrations. (D) Signage requirements for non-single family graywater treatment works (categories B and D). (1) All required notifications shall include posting of signs of sufficient size to be clearly read with the language below in the dominant language(s) expected to be spoken at the site. (2) All non-single family graywater treatment works (categories B and D). All non-single graywater treatment works must comply with the following signage requirements. a. A permanent warning sign must be visible at all fixtures from which graywater is collected. The signs must state that, "WATER FROM THIS FIXTURE IS REUSED. CHEMICALS, EXCRETA, PETROLEUM OILS AND HAZARDOUS MATERIALS MUST NOT BE DISPOSED DOWN THE DRAIN"; b. Each room that contains graywater treatment works components must have a sign that says "CAUTION GRAYWATER TREATMENT WORKS, DO NOT DRINK, DO NOT CONNECT TO THE POTABLE DRINKING WATER SYSTEM. NOTICE: CONTACT BUILDING MANAGEMENT BEFORE PERFORMING ANY WORK ON THIS WATER SYSTEM." (3) Non-single family, subsurface irrigation non-single family graywater treatment works (categories B and D). Non-single family, subsurface irrigation graywater treatment works (categories B and D, if applicable) must comply with the following signage requirement: Each irrigation area must have a sign that says "CAUTION GRAYWATER BEING USED FOR IRRIGATION. DO NOT DRINK, DO NOT CONNECT TO THE POTABLE DRINKING WATER SYSTEM." (4) Non-single family, indoor toilet or urinal flushing, non-single family graywater treatment works (category D). Non-single family, indoor toilet and urinal flushing graywater treatment works (category D) must comply with the following signage requirement: Each toilet and urinal must have a sign that says: "TO CONSERVE WATER, THIS BUILDING USES TREATED NON-POTABLE GRAYWATER TO FLUSH TOILETS AND URINALS."

(Ord. No. 2158, § 1, 9-14-2021)

Ask a question about Broomfield law

Corpus searches the Broomfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.