§ 13-42-070 — Operation and Maintenance
Municipal Code of the City and County of Broomfield, Colorado (Codified through Ordinance No. 2304, adopted May 26, 2026 (Supp. No. 54)) · Broomfield Municipal Code § 13-42-070
Corpus is an independent public-information project, not the official City of Broomfield website. Stable reference: corpuslaw.us/code/5e34c995-9ded-4fdf-94f7-2c5119014803
13-42-070 - Operation and Maintenance.
(A) Operations and maintenance (O&M) manual. All graywater systems must have an O&M manual. The O&M manual must include the following items: (1) A graywater treatment works description including: equipment list, design basis data including but not limited to, design volumes, design flow rates of each component and service area, system as- built drawing, and process description. (2) Maintenance information for the graywater treatment works including but not limited to: component maintenance schedule, instructions for component repair, replacement, or cleaning, replacement component source list, testing and frequency for potable containment device, and instructions for periodic removal of residuals. (3) Operational ranges for parameters including but not limited to: disinfectant concentration levels, filter replacement parameters, pressure ranges, tank level, and valve status under normal operation. (4) Step-by-step instructions for starting and shutting down the graywater treatment works including but not limited to: valve operation, any electrical connections, cleaning procedures, visual inspection, and filter installation. (5) A guide for visually evaluating the graywater treatment works and narrowing any problem scope based on alarm activations, effluent characteristics, system operation, and history. (6) A list of graywater control measures in which the graywater treatment works must be operated. (B) Control measures. Control measures are operational requirements representing best management practices that graywater systems must follow when operating a graywater treatment works. (1) Control measures that apply to all graywater uses. All graywater treatment works must be operated in accordance with the following control measures: a. Graywater must be collected in a manner that minimizes the presence or introduction of: 1. Hazardous or toxic chemicals in the graywater to the greatest extent possible; 2. Human excreta in the graywater to the greatest extent possible; 3. Household wastes; and 4. Animal or vegetable matter. b. Use of graywater is limited to the confines of the facility that generates the graywater. c. The graywater treatment works must be operated and maintained in accordance with the O&M manual, including all manufacturer recommended maintenance activities. The O&M manual must remain with the graywater treatment works throughout the system's life and be updated based on each modification and approval made to the system. d. Prior to or upon change of ownership or occupancy, the O&M manual must be transferred to the new owner or tenant. e. Prior to or upon transfer of the property to a new owner, the transferor must provide written notice of the presence of the system on the property to the new owner (the new legally responsible party). The notice must include a copy of the O&M manual, any operational and maintenance records, and the most recent permit issued. f. If the new owner does not obtain a permit to continue to operate the system as required by section 13-42-030(H), the system shall be physically removed or permanently disconnected within ninety days of the property transfer. g. For category D graywater treatment works that have a capacity to receive greater than 2,000 gallons per day (gpd), operational and maintenance records must be maintained for a minimum of the past five years. h. The owner or operator of a graywater treatment works must minimize exposure of graywater to humans and domestic pets. i. Graywater use and graywater treatment works must not create a public nuisance. j. Graywater must not be stored for more than twenty-four hours unless the graywater has been treated by a graywater treatment works that meets the design requirements of 5 CCR 1002-86.12. All graywater must be stored inside a tank(s) that meets the design requirements of 5 CCR 1002-86.12(A)(5). k. Temporary or semi-temporary connections from the potable water system or public water system to the graywater treatment works are prohibited. Permanent connections from the potable water system or public water system to the graywater treatment works must meet the design requirements of 5 CCR 1002-86.11(A)(6). (C) Control measures that apply to subsurface irrigation graywater use. Subsurface irrigation graywater treatment works must be operated in accordance with the following additional control measures: (1) Agricultural irrigation with graywater is prohibited. (2) Irrigation is prohibited when the ground is frozen, plants are dormant, during rainfall events, or the ground is saturated. (3) Irrigation scheduling must be adjusted so that application rates are closely matched with soil and weather conditions. (4) Graywater must be applied in a manner that does not result in ponding, runoff, or unauthorized discharge to state waters. For dispersed subsurface irrigation systems, the graywater must be applied at an agronomic rate. For mulch basins systems, the graywater must not be applied in excess of the soil adsorption rate. (5) For mulch basin systems, mulch must be replenished and undergo periodic maintenance as needed to reshape or remove material to maintain surge capacity and to prevent ponding and runoff. (D) Control measures that apply to indoor toilet and urinal flushing graywater use. Indoor toilet and urinal flushing graywater treatment works (categories C and D) must be operated in accordance with the following additional control measures. (1) Graywater for toilet and urinal flushing use must be disinfected. a. Graywater treatment works that utilize chlorine for disinfection must have a minimum of 0.2 mg/L and a maximum of 4.0 mg/L of free chlorine residual throughout the indoor graywater plumbing system, including fixtures. b. Single family graywater treatment works that utilize non-chemical methods, such as UV, for disinfection must have a chlorine puck present in each toilet or urinal tank. (2) Graywater for toilet and urinal flushing must be dyed with either blue or green food grade vegetable dye and be visibly distinct from potable water. (E) Certified operator. A graywater treatment system must be operated by qualified personnel who meet any applicable requirements of 5 CCR 1003-2, the Water and Wastewater Facility Operators Certification Requirements.
(Ord. No. 2158, § 1, 9-14-2021)
Ask a question about Broomfield law
Corpus searches the Broomfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.
