§ 15-04-010 — Amendments to the International Building Code

Municipal Code of the City and County of Broomfield, Colorado (Codified through Ordinance No. 2304, adopted May 26, 2026 (Supp. No. 54)) · Broomfield Municipal Code § 15-04-010

Corpus is an independent public-information project, not the official City of Broomfield website. Stable reference: corpuslaw.us/code/5f6a2edd-14c3-4f85-bbd8-a341b538e31f

15-04-010 - Amendments to the International Building Code.

The following amendments are hereby made to the 2024 International Building Code which shall be referred to in this chapter 15-04 as the IBC: (A) Chapter 1 is hereby deleted. Refer to chapter 15-03, B.M.C., for administrative requirements. (B) Section 305.2.3 is amended to read as follows: 305.2.3 Twelve or fewer children in a dwelling unit. A facility such as above within a dwelling unit and having twelve or fewer children, including children 2 ½ years and younger, receiving such day care shall be classified as a Group R-3 occupancy or shall comply with the International Residential Code. (C) Section 308.2.3 is amended to read as follows: Section 308.2.3 Nine to 16 Persons receiving custodial care. A facility housing not fewer than nine and not more than 16 persons receiving custodial care shall be classified as Group R-4. (D) Section 308.2.4 is amended to read as follows: Section 308.2.4 Eight or fewer persons receiving custodial care. A facility with eight or fewer persons receiving custodial care shall be classified as Group R-3 or shall comply with the International Residential Code provided an automatic sprinkler system is installed in accordance with Section 903.1.3 or Section P2904 of the International Residential Code. (E) Section 308.5.4 is amended to read as follows: Section 308.5.4 Eight or fewer persons receiving care in a dwelling unit. A facility such as the above within a dwelling unit and having eight or fewer persons receiving custodial care shall be classified as a Group R-3 occupancy or shall comply with the International Residential Code. (F) Section 310.4 is amended to read as follows: Section 310.4 Residential Group R-3. Residential Group R-3 occupancies where the occupants are primarily permanent in nature and not classified as Group R-1, R-2, R-4, or I, including: Buildings that do not contain more than two dwelling units Care facilities that provide accommodations for eight or fewer persons receiving care. Rest of code language to remain (G) Section 310.4.1 is amended to read as follows: Section 310.4.1 Care facilities within a dwelling. Care facilities for eight or fewer persons receiving care that are within a single family dwelling are permitted to comply with the International Residential Code provided an automatic sprinkler system is installed in accordance with Section 903.1.3 or Section P2904 of the International Residential Code. (H) Section 310.5 is amended to read as follows: Section 310.5 Residential Group R-4. Residential Group R-4 occupancy shall include buildings or structures or portions thereof for more than eight but not more than 16 persons, excluding staff in a supervised residential environment and receive custodial care. Rest of code language to remain (I) Amend footnote g for Table 705.8 to read as follows: g. The area of openings in an open parking garage in accordance with Section 406.5 with a fire separation distance of 10 feet or greater shall not be limited. (J) Amend Section 707.6 to add the new exceptions below: 6. Openings shall not be limited to an aggregate width of 25 percent of the length of the wall where opening serves a shaft enclosure in accordance with Section 713. 7. Openings shall not be limited to an aggregate of 25 percent of the length of the wall where opening serves a chute access room in accordance with Section 713.13.3 or a chute discharge room in accordance with Section 713.13.4. (K) Section 903.2.8.4 is amended to read as follows: Section 903.2.8.4 Care Facilities. An automatic sprinkler system installed in accordance with Section 903.3.1.3 shall be permitted in care facilities with eight or fewer individuals in a single family dwelling (L) Subsection 905.2, Installation standard, of the IBC is amended to read as follows: 905.2 Installation standard. Standpipe systems shall be installed in accordance with this section and NFPA 14. Fire department connections for standpipe systems shall be in accordance with Section 912. Fire hose is not required for any class of standpipe system. (M) Subsection 912.1, Installation, of the IBC is amended to read as follows: 912.1 Installation. Fire department connections shall be installed in accordance with this section and the NFPA standard applicable to the system design and shall comply with Sections 912.2 through 912.7. Unless the incorporation of large diameter Storz-style connections are specifically approved by the Fire District, the number of 2.5-inch inlets provided shall not be less than one for each 250 gallons per minute of system demand or major fraction thereof, to a maximum of six 2.5-inch inlets. Each 2.5-inch inlet shall be equipped with a clapper valve to allow each hose to be connected and charged before the addition of more hoses. (N) The word "carpets" is hereby deleted from Section 1011.5.1 and this section will now read: Section 1011.5.1 Dimension reference surfaces. For the purpose of this section, all dimensions are exclusive of rugs or runners. (O) Section 1011.12 is amended to read as follows: 1011.12 Stairway to roof. In buildings four or more stories above grade plane, one stairway shall extend to the roof surface, unless the roof has a slope steeper than four units vertical in 12 units horizontal (33-percent slope). When an exit enclosure is required by Section 1022, the stairway to the roof shall be located within an exit enclosure. In buildings without an occupied roof, access to the roof from the top story shall be permitted to be by an alternating tread device. (P) Section 1015.8 is amended to read as follows: 1015.8 Window openings. Windows in Group R-2 and R-3 buildings including dwelling units, where the bottom of an operable opening is located less than 36 inches above the finished floor and more than 72 inches above the finished grade or other surfaces below on the exterior of the building, shall comply with one of the following: (Q) A new Exception to Section 1202.4 shall be added to read as follows: EXCEPTION. Ventilation is not required for spaces below noncombustible structural basement floors located below grade. (R) Amend Section 1006.3 to read as follows: 1006.3 Egress from stories or occupied roofs. All spaces located on a story or occupied roof shall have access to the required number of separate and distinct exits based on the aggregate occupant load served in accordance with this section. (S) Section 1107.2.3 Accessible route. Accessible vehicle spaces shall be located on the shortest accessible route from spaces to an accessible building entrance. (T) A new Exception to Section 1208.1 shall be added to read as follows: EXCEPTION: Access is not required for spaces below noncombustible structural basement floors where there is no building equipment such as electrical, plumbing, mechanical or gas systems. (U) Section 1608.2 is amended to read as follows: 1608.2 Ground Snow Loads. The ground snow load shall be 30 psf as per ASCE 7-22 Hazard Tool for specific address. The design roof snow load shall be no less than 30 psf at any element of the roof the same as the ground snow load. (V) Section 1612.3 is amended to read as follows: 1612.3 Establishment of flood hazard areas. To establish flood hazard areas, the applicable governing authority shall adopt a flood hazard map and supporting data. The flood hazard map shall include, at a minimum, areas of special flood hazard as identified by the Federal Emergency Management Agency in an engineering report entitled "The Flood Insurance Study for City and County of Broomfield," dated August 15, 2019, as amended or revised with the accompanying Flood Insurance Rate Map (FIRM) and the Flood Boundary and Floodway Map (FBFM) and related supporting data along with any revisions thereto. The adopted flood hazard map supporting data are hereby adopted by reference and declared to be part of this section. (W) Delete Section 1705.2 in its entirety (X) Section 1705.18 Fire-resistant penetrations and joints, is hereby deleted in its entirety. (Y) Section 1803.5.3 Expansive soils is amended to read as follows: 1803.5.3 Expansive soils. 1803.5.3.1 General. Expansive soils are deemed present throughout most of the city and county. A soils report and engineered foundation plan are required for all new construction. Such plans must be prepared by a Colorado registered professional engineer. The documents shall specifically include design computations for pier diameter and length for commercial construction, describe methods to provide restraint from lateral soil pressures, provide a slab performance risk evaluation, compaction and soil preparation requirements for slabs on grade, and other information deemed necessary by the engineer of record. EXCEPTION: If the existing foundation for a building is performing adequately, foundations for additions to existing buildings are allowed to match the existing foundation type. 1803.5.3.2 Borings. Borings shall be conducted on each lot to determine consistency of soil conditions with the soil investigation report. When isolated residences are investigated, at least two borings shall be drilled on each lot, generally at opposite corners of the proposed structure. When more than two adjacent lots are being investigated, at least one boring shall be drilled near the center of each building footprint. The depth of boring may be varied when each lot is located in a subdivision containing multiple lots. 1803.5.3.3 Water Control. All foundations are required to be provided with perimeter drainage systems. The perimeter drainage system shall be designed to collect water around below-grade foundation walls which define rooms or areas which either are or could become habitable spaces. EXCEPTION: The Building Official may waive such requirements when sufficient documentation is provided by the engineer of record to substantiate his or her recommendation that such system is not necessary. 1803.5.3.3.1 Materials. Piping in conformance with ASTM Designation D2729-89 or equivalent shall be used for perimeter drains. 1803.5.3.3.2 Termination. Unless perimeter drains are designed to daylight, they shall terminate in sump pits with pumps installed. Piping for sump pumps shall discharge at least five feet away from foundations or as otherwise approved by the Building Official. 1803.5.3.3.3 Installation. Perimeter drains shall be installed in proper bedding materials. The bedding materials shall be of such size and installed in such manner to allow groundwater to seep into the perimeter drain. Landscape fabric or other measures to restrict the passage of fines shall be used to further protect the perimeter drain from blockage. 1803.5.3.4 Special inspections. 1803.5.3.4.1 Pier drilling log. The pier inspections shall be reported on a drilling log which contains detailed information on each hole including total depth, depth to bedrock, descriptions of the various strata the hole was drilled through, the condition of the hole, and whether groundwater was encountered; the drilling log shall be stamped by a Colorado licensed professional engineer. Such inspection shall confirm compliance with the design drawings and other provisions of this code. See also Section 1705.8. 1803.5.3.4.2 Foundation walls. Foundation walls shall be inspected just prior to placement of concrete. The inspection shall be under the supervision of a Colorado licensed professional engineer. Such inspection shall confirm compliance with the design drawings and other provisions of this code. 1803.5.3.4.2.1 Foundation, under slab, and excavation trench backfill. Foundation, under slab, and excavation trench backfill shall be moisture conditioned and compacted to control settlement. Additionally, all backfill and compaction recommendations contained in the geotechnical report and the structural engineer's foundation design shall be followed. If conflicts exist, the most stringent requirement shall be followed. Fill materials shall not contain debris, clods over 6" diameter, or frozen soil. Water shall be added uniformly to the stockpiled materials, or as backfill is placed so that water content at the time of compaction is within tolerances established by the engineering documents. Flooding or puddling of the backfill is not allowed. Fill shall be placed in loose lifts as established by the engineering documents. The surface of each lift shall be compacted as established by the engineering documents. Over-compaction shall be avoided to reduce potential wall damage. Backfill and compaction of foundation walls shall not take place until the wall has gained sufficient strength, temporary bracing of the walls is provided, or other equivalent measures are used to limit damage to walls during the backfill and compaction process. The placement and compaction of foundation, under slab, and excavation trench backfill shall be observed by a person working under the supervision of a Colorado licensed professional engineer. The observations shall be performed at a frequency sufficient to provide reasonable assurance that backfill has been placed in substantial conformance with these requirements. At least one observation visit shall be performed for each of the following: foundation backfill, trench backfill, and under slab preparation. 1803.5.3.4.3 Perimeter drainage and dampproofing. Perimeter drainage systems and dampproofing of foundation walls shall be inspected under the supervision of a Colorado licensed professional engineer. 1803.5.3.4.4 Basement floors. All slab on grade and structural floor systems shall be inspected under the supervision of a Colorado licensed professional engineer. 1803.5.3.4.5 Reporting. Reports for the above-mentioned special inspections shall be submitted at least three (3) business days before framing inspections and shall be stamped by a Colorado licensed professional engineer. Framing inspections will not be performed by the city prior to receipt of the special inspection reports. 1803.5.3.5 Basement floors. All residential basement floors exceeding 150 square feet in area shall be constructed as structural floor systems. When such floor systems are designed to withstand lateral foundation loads as well as floor loading, the plans shall so indicate. EXCEPTION: Slab-on-grade basement floors may be used when the slab performance risk evaluation is low or moderate and sufficient documentation is provided by the engineer of record to substantiate the performance risk assessment. Such assessment shall include but not be limited to consideration of all of the following factors: geologic structure; soil and bedrock profile and profile variability; material type and engineering properties of materials below the slab; swell tests and/or suction tests; depth and magnitude of moisture increase; existing and anticipated ground water conditions; location of any nearby surface water sources; type of basement; tolerable movement for the intended use; performance history and experience in the area; surface topography; previous and future grading; surface and subsurface drainage; and site landscaping, irrigation and vegetation. The slab performance risk shall be defined as shown in Table 1803.5.2.5. TABLE 1803.5.2.5 Swell Potential Descriptions and Corresponding Slab Performance Risk Categories Slab Performance Risk Category | Representative Percent Swell (500 psf Surcharge) | Representative Percent Swell (1000 psf Surcharge) Low | 0 to < 3 | 0 to < 2 Moderate | 3 to < 5 | 2 to < 4 High | 5 to < 8 | 4 to < 6 Very High | ≥ 8 | ≥ 6 Note: The representative percent swell values presented are not measured values; rather, they are a judgment of the swell of the soil and bedrock profile likely to influence performance. The Building Official may, however, determine that the documentation is insufficient to support the exception. Developers and builders or their representatives shall comply with the disclosure to purchaser requirements set forth in Section 6-6.5-101, C.R.S. In addition, prior to issuance of a certificate of occupancy for a residence with a slab-on-grade basement floor, a statement signed by the homebuyer shall be submitted wherein the homebuyer acknowledges to have read the soils report and/or summary soils report, understands the risks associated with a slab-on-grade basement floor, and chooses to accept those risks. If the buyer is unknown at the time of issuance of a certificate of occupancy, the statement shall be prepared and signed by the builder. In either case, the statement shall be recorded by the builder in the office of the county clerk and recorder. The builder shall pay the recording fee. The statement shall also include the name of the builder, the legal description of the property, and any other pertinent information required by the building official. New walls for basement finishes in existing buildings with existing slab-on-grade floors shall be provided with a slip joint (or float) in accordance with the soils report for the site to allow for vertical slab movement. In the absence of a soil report, a minimum of 1½" slip joint shall be provided. Doorways shall also be designed to allow vertical movement, and wall finish materials shall not extend to the floor. 1803.5.3.5.1 Ventilation. Adequate underfloor ventilation systems shall be provided to ventilate underfloor areas when structural floor systems are required. Such systems shall be designed to provide at least one air change per hour, be controlled by a de-humidistat, and exhaust to the outside. EXCEPTIONS: 1. The building official may approve alternates to such requirements when sufficient documentation is provided by the engineer of record to substantiate his or her alternate method is at least the equivalent of that prescribed. 2. Ventilation is not required for spaces below noncombustible structural basement floors located below grade. 1803.5.3.5.2 Under Floor Grading. When structural basement floors are installed, a minimum of 18" of clear space is required below untreated wood floor joists and any wood girders or beams. Where steel or concrete beams or joists are used, the minimum clearance shall be as recommended by the soils engineer. The surface of the underfloor area shall be graded to a relatively flat plane to slope toward the sump pit, or toward drain systems installed to control free water in the underfloor space. The underfloor area shall not allow ponding of water. (Z) A new Section J112, Site Grading, is added to Appendix J to read as follows: Section J112 Site Grading. J112.1 General. Grading shall be performed in such a manner as to minimize impact from drainage on adjacent properties and to minimize damage to structures. The provisions of this section are minimums, and greater protection may be required by the soil report or engineered foundation plan. J112.2 Gutters and Downspouts. Gutters will be required on all eave portions of roofs. The location and direction of downspouts shall be such that no drainage or ponding problems are created and water is carried a minimum distance of five (5) feet from buildings or as recommended by the soils report. Where practical, downspouts shall not discharge onto hard surfaces, driveways, sidewalks, or patios. J112.3 Site grading plans and certificates. J112.3.1 General. All grading is required to secure a permit from the City and County Engineering Department and follow the current City Engineering Standards.

(Ord. 1926 §11, 2011; Ord. 1953 §1, 2012; Ord. 1994 §8, 2014; Ord. 2042 §7, 2017; Ord. No. 2115, 2-25-20; Ord. No. 2205, 3-7-23; Ord. No. 2233, § 4, 7-23-24; Ord. No. 2295, § 2, 2-24-26)

Ask a question about Broomfield law

Corpus searches the Broomfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.