§ 15-05-010 — Amendments to the International Residential Code

Municipal Code of the City and County of Broomfield, Colorado (Codified through Ordinance No. 2304, adopted May 26, 2026 (Supp. No. 54)) · Broomfield Municipal Code § 15-05-010

Corpus is an independent public-information project, not the official City of Broomfield website. Stable reference: corpuslaw.us/code/9141882a-bf85-4679-9a33-e3075b576ebb

15-05-010 - Amendments to the International Residential Code.

The following amendments are hereby made to the 2024 International Residential Code, which shall be referred to in this chapter 15-05 as the IRC: (A) Chapter 1 is hereby deleted. Refer to chapter 15-03, B.M.C., for administrative requirements. (B) Amend Section R202 Definition for Exterior Wall to read as follows: [RE] (RB) EXTERIOR WALL. An above-grade wall that defines the exterior boundaries of a building. Includes between-floor spandrels, peripheral edges of floors, roof and basement knee walls, dormer walls, gable end walls, gable end roof trusses, walls enclosing a mansard roof and basement walls with an average below-grade wall area that is less than 50 percent of the total opaque and nonopaque area of that enclosing side. For the definition applicable in Chapter 11, see Section N1101.6. (C) Table R301.2(1), Climatic and geographic design criteria is hereby amended as follows: TABLE R301.2(1) Climatic and Geographic Design Criteria GROUND AND ROOF SNOW LOAD: | 42 OR ASCE 7-22 WIND SPEED (mph): | Design per ASCE 7-22 SEISMIC DESIGN CATEGORY: | B SUBJECT TO DAMAGE FROM: Weathering: | Severe Frost line depth: | 36" Termite: | n/a WINTER DESIGN TEMP: | 1°F ICE BARRIER UNDERLAYMENT REQUIRED: | No FLOOD HAZARDS: | 1973/1988 AIR FREEZING INDEX: | 500-1000 ANNUAL MEAN TEMP: | 50°F FIRM Panel Dates for Printed Panels of Broomfield, Colorado: 0850730040F, 0850730059F, 0850730067F, 0850730070F, 0850730078F, 0850730105F all with an effective date ranging from August 18, 2004 to August 15, 2019. 0850730079G, 0850730083G, 0850730085G, 0850730086G, 0850730087G, 0850730088G, 0850730089G, 0850730091G all with effective date ranging from August 18, 2004 to August 15, 2019. 0850730092H with effective date ranging from August 18, 2004 to August 15, 2019. (D) Tables R302.1(1) and R302.1(2) are amended as follows: Footnote b from Table R302.1(1) and footnote c from Table R302.1(2) are deleted. (E) Section R302.1 is amended to read as follows: R302.1 Exterior walls. Construction, projections, openings and penetrations of exterior walls of dwellings and accessory buildings shall comply with Table R302.1(1); or dwellings equipped throughout with an automatic sprinkler system installed in accordance with Section P2904 shall comply with Table R302.1(2). Fire-resistant rated exterior walls shall extend from the top of the foundation to the underside of the roof sheathing. If the soffit is protected with one hour fire rated construction the fire-resistant rated exterior wall shall be permitted to terminate in line with the level of the soffit protection. Exceptions: 1. Walls, projections, openings or penetrations in walls perpendicular to the line used to determine the fire separation distance. 2. Walls of individual dwelling units and their accessory structures located on the same lot. 3. Detached tool sheds and storage sheds, playhouses and similar structures exempted from permits are not required to provide wall protection based on location on the lot. Projections beyond the exterior wall shall not extend over the lot line. 4. Detached garages accessory to a dwelling located within 2 feet (610 mm) of a lot line are permitted to have roof eave projections not exceeding 4 inches (102 mm). (F) Section R308.4.6 is amended to read as follows: R308.4.6 Glazing adjacent to stairs and ramps. Glazing where the bottom exposed edge of the glazing is less than 60 inches (1524 mm) above the plane of the adjacent walking surface of stairways, landings between flights of stairs and ramps shall be considered a hazardous location. EXCEPTIONS: 1. When a rail is installed on the accessible side(s) of the glazing 34 to 38 inches (864 to 965 mm) above the walking surface and the plane of glass is more than 18 inches (457 mm) horizontally from the rail. The rail shall be capable of withstanding a horizontal load of 50 pounds per linear foot (730 N/m) without contacting the glass and be a minimum of 1½ inches (38 mm) in cross sectional height. 2. Glazing 36 inches (914 mm) or more measured horizontally from the walking surface. (G) Section R308.4.7 is amended to read as follows: R308.4.7 Glazing adjacent to the bottom stair landing. Glazing adjacent to the landing at the bottom of a stairway where the glazing is less than 60 inches (1524 mm) above the landing and within a 60 inch (1524 mm) horizontal arc less than 180 degrees the bottom tread shall be considered a hazardous location. EXCEPTION: The glazing is protected by a guard complying with Section R312 and the plane of glass is more than 18 inches (457 mm) from the guard. (H) Section R311.7.5 is hereby amended by deleting the word "carpets": R311.7.5 Stair treads and risers. Stair treads and risers shall meet the requirements of this section. For the purposes of this section, the dimensions and dimensioned surfaces shall be exclusive of rugs and runners. (I) Section R311.7.7 is hereby amended to read: R311.7.7 Stairway walking surface. The walking surface of treads and landings of stairways shall be sloped not steeper than 1 unit vertical in 48 units horizontal (2-percent slope). Exception: Where the surface of a landing is required elsewhere in the code to drain surface water, the walking surface of the landing shall be sloped not steeper than 1 unit vertical in 20 units horizontal (5-percent slope) in the direction of travel. R311.7.7.1 Landings at grade. Stairway landings located at grade shall be solid and stable. (J) Section R313.1 is hereby amended to read as follows: R313.1 Townhouse automatic sprinkler systems. An automatic residential fire sprinkler system shall be installed in all new townhouses. EXCEPTION 1: An automatic residential fire sprinkler system shall not be required when additions or alterations are made to existing townhouses that do not have an automatic residential fire sprinkler system installed. EXCEPTION 2: An automatic residential fire sprinkler system shall not be required for detached Accessory Dwelling Units where the existing primary structure does not have an automatic residential fire sprinkler system installed. EXCEPTION 3: An automatic residential fire sprinkler system shall not be required where an existing tap from a city main water line serving the building and a water meter pit have been installed and approved without adequate capacity for an automatic sprinkler system. R313.1.1 Design and installation. Automatic residential fire sprinkler systems for townhouses shall be designed and installed in accordance with Section P2904 or NFPA 13D. (K) Section R313.2 is hereby amended to require automatic residential fire sprinklers as follows: R313.2 One- and two-family dwellings automatic fire sprinkler systems. An automatic residential fire sprinkler system shall be installed in one- and two-family dwellings. EXCEPTION 1: An automatic residential fire sprinkler system shall not be required when additions or alterations are made to existing buildings that are not already provided with an automatic residential sprinkler system. EXCEPTION 2: An automatic residential fire sprinkler system shall not be required for detached Accessory Dwelling Units where the existing primary structure does not have an automatic residential fire sprinkler system installed. EXCEPTION 3: An automatic residential fire sprinkler system shall not be required where an existing tap from a city main water line serving the building and a water meter pit have been installed and approved without adequate capacity for an automatic sprinkler system. (L) Section R314.2.2 is amended to read as follows: R314.2.2 Alterations, repairs and additions. When alterations, repairs or additions requiring a permit occur, or when one or more sleeping rooms are added or created in existing dwellings, the individual dwelling unit shall be equipped with smoke alarms located as required for new dwellings. EXCEPTIONS: 1. Work involving the exterior surfaces of dwellings, such as the replacement of roofing or siding, or the addition of a porch or deck, are exempt from the requirements of this section. 2. Repairs of plumbing or mechanical systems are exempt from the requirements of this section. (M) Under the Exceptions of Subsection R314.4, Alterations, repairs and additions, the exception numbered 2 is hereby amended to read as follows: 2. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where battery-operated detectors are provided and no electrical work is being performed in the area requiring a detector. (N) Section R324.6 is hereby amended to read as follows: R324.6 Roof access and pathways. R324.6.1 Emergency escape and rescue opening. Panels and module installed on dwellings shall not be placed on the portion of the roof that is below an emergency escape and rescue opening. A pathway not less than 36 inches (914 mm) shall be provided to the emergency escape and rescue opening. (O) Subsection R401.3, Drainage, is hereby amended to read as follows: R401.3 Drainage and site grading. R401.3.1 General. Grading shall be performed in such a manner as to minimize impact from drainage on adjacent properties and to minimize damage to structures. The provisions of this section are minimums, and greater protection may be required by the soil report or engineered foundation plan. R401.3.2 Yards. All yards shall have a minimum slope of five (5) percent and a maximum slope of twenty-five (25) percent away from the building for a minimum distance often (10) feet from the building, except where lot lines, walls, slopes, or other physical barriers prohibit 6 inches (152 mm) of fall within 10 feet (3048 mm), drains and swales shall be provided to ensure drainage away from the structure. R401.3.3 Seasonal limits. No fill material shall be placed, spread, or rolled while it is frozen or thawing or during unfavorable weather conditions. R401.3.4 Gutters and downspouts. Gutters shall be provided on all eave portions of roofs. The location and direction of downspouts shall be such that no drainage or ponding problems are created and water is carried a minimum distance of three (3) feet from buildings. Where practical, downspouts shall not dump onto hard surfaces, driveways, sidewalks, or patios. R401.3.7 Site grading plans and certificates. R401.3.7.1 General. Grading performance plans and grading performance certificates are required in conjunction with building permits for new one- and two-family dwellings. The city engineer may waive this requirement if he or she determines that adequate grading and drainage plans have been otherwise approved and implemented. R401.3.7.2 Grading performance plans. Each building permit application shall be accompanied by a site drainage plan. The plan shall indicate the following: 1. Direction of flow. 2. Grade elevations sufficient to show percent of slope along property lines, drainage swales, and away from the house. NOTE: In addition to the minimum yard drainage requirements in Section R401.3.2, all other locations shall provide a minimum two-percent slope. 3. Conformance with overall subdivision drainage plan. R401.3.7.3 Grading performance certificate. Prior to issuance of a certificate of occupancy, a grading performance certificate shall be provided to the building official. The document shall be prepared by a Colorado registered professional engineer. The grading performance certificate shall indicate and affirm the following: 1. Direction of flow. 2. Grade elevations sufficient to show percent of slope along property lines, drainage swales, and away from the house. NOTE: In addition to the minimum yard drainage requirements in Section 401.3.2, all other locations shall provide a minimum two-percent slope. 3. Conformance with overall subdivision drainage plan. 4. An affirmative statement that the inspection of the site has been performed and that the lot will drain adequately and in conformance with the grading performance plan. The grading shall be maintained by the property owner in accordance with the grading performance certificate. Any subsequent installation of landscaping or building improvements shall neither substantially deviate from the grading performance certificate nor contribute to drainage problems on adjacent properties. R401.3.7.4 Grading noncompliance request. When inclement weather, soil conditions, or other reasons force the postponement of final grading, so a final grading performance certificate cannot be provided. Clean-up permit shall be submitted with the description for providing a final or revised final grade performance certificate within a time frame given by the building official, and with a fee of $100.00. The clean-up permit shall take the place of a grading performance certificate for up to the days determined by the building official based on the time of year, weather, soil conditions and the practicality of getting the work completed in the period of time indicated on the permit. After such time, the statement expires, and remedies in chapter 1-12 B.M.C. may be pursued. (P) Subsection R401.4, Soil tests, is hereby amended to read as follows: R401.4 Expansive soils. R401.4.1 General. Expansive soils are deemed present throughout most of the city. A soils report and engineered foundation plan are required for all new construction. Such plans must be prepared by a Colorado registered professional engineer. The documents shall specifically include design computations for pier diameter and length, describe methods to provide restraint from lateral soil pressures, provide a slab performance risk evaluation, compaction and soil preparation requirements for slabs on grade, and other information deemed necessary by the engineer of record. EXCEPTION: If the existing foundation for a building is performing adequately, foundations for additions to existing buildings are allowed to match the existing foundation type. R401.4.2 Borings. Borings shall be conducted on each lot to determine consistency of soil conditions with the soil investigation report. When isolated residences are investigated, at least two borings shall be drilled on each lot, generally at opposite corners of the proposed structure. When more than two adjacent lots are being investigated, at least one boring shall be drilled near the center of each building footprint. The depth of boring may be varied when each lot is located in a subdivision containing multiple lots. R401.4.3 Water control. All residential foundations are required to be provided with perimeter drainage systems. The perimeter drainage system shall be designed to collect water around below-grade foundation walls which define rooms or areas which either are or could become habitable spaces. EXCEPTION: The building official may waive such requirements when sufficient documentation is provided by the engineer of record to substantiate his or her recommendation that such system is not necessary. R401.4.3.1 Materials. Piping in conformance with ASTM Designation D2729-89 or equivalent shall be used for perimeter drains. R401.4.3.2 Termination. Unless perimeter drains are designed to daylight, they shall terminate in sump pits with pumps installed. Piping for sump pumps shall discharge to the underdrain pipe system if provided or at least five feet away from foundations or as otherwise approved by the building official. R401.4.3.3 Installation. Perimeter drains shall be installed in proper bedding materials. The bedding materials shall be of such size and installed in such manner to allow groundwater to seep into the perimeter drain. Landscape fabric or other measures to restrict the passage of fines shall be used to further protect the perimeter drain from blockage. R401.4.4 Special inspections. R401.4.4.1 Piers. A sufficient number of the piers, but in no case less than 25%, shall be inspected, as determined necessary by the special inspector, to verify consistency of soil report findings. Such piers shall be selected from all levels when there is more than one level and at opposite corners of the structure. Such inspection shall confirm compliance with the design drawings and other provisions of this code. R401.4.4.2 Pier drilling log. The pier inspections shall be reported on a drilling log which contains detailed information on each hole including total depth, depth to bedrock, descriptions of the various strata the hole was drilled through, the condition of the hole, and whether groundwater was encountered; the drilling log shall be stamped by a Colorado licensed professional engineer. R401.4.4.3 Foundation walls. Foundation walls shall be inspected just prior to placement of concrete. The inspection shall be under the supervision of a Colorado licensed professional engineer. Such inspection shall confirm compliance with the design drawings and other provisions of this code. R401.4.4.3.1 Foundation, under basement slab, and excavation trench backfill. Foundation, under basement slab, and excavation trench backfill shall be moisture conditioned and compacted to control settlement. Additionally, all backfill and compaction recommendations contained in the geotechnical report and the structural engineer's foundation design shall be followed. If conflicts exist, the most stringent requirement shall be followed. Fill materials shall not contain debris, dirt clods over 6" diameter, or frozen soil. Water shall be added uniformly to the stockpiled materials, or as backfill is placed so that water content at the time of compaction is within tolerances established by the engineering documents. Flooding or puddling of the backfill is not allowed. Fill shall be placed in loose lifts as established by the engineering documents. The surface of each lift shall be compacted as established by the engineering documents. Over-compaction shall be avoided to reduce potential wall damage. Backfill and compaction of foundation walls shall not take place until the wall has gained sufficient strength, temporary bracing of the walls is provided, or other equivalent measures are used to limit damage to walls during the backfill and compaction process. The placement and compaction of foundation, basement under slab, and excavation trench backfill shall be observed by a person working under the supervision of a Colorado licensed professional engineer. The observations shall be performed at a frequency sufficient to provide reasonable assurance that backfill has been placed in substantial conformance with these requirements. At least one observation visit shall be performed for each of the following: foundation backfill, trench backfill, and basement under slab preparation. R401.4.4.4 Perimeter drainage and dampproofing. Perimeter drainage systems and dampproofing of foundation walls shall be inspected under the supervision of a Colorado licensed professional engineer. R401.4.4.5 Basement floors. All structural floor systems shall be inspected under the supervision of a Colorado licensed professional engineer. Refer to the site specific soils report for slab on grade inspection requirements and to the engineered structural floor plans for the structural floor inspection requirements. R401.4.4.6 Reporting. Reports for the above-mentioned special inspections shall be submitted at least three (3) business days before frame inspection and shall be stamped by a Colorado licensed professional engineer. Framing inspections will not be performed by the city prior to receipt of the special inspection reports. R401.4.5 Basement floors. All residential basement floors exceeding 150 square feet in area shall be constructed as structural floor systems. When such floor systems are designed to withstand lateral foundation loads as well as floor loading, the plans shall so indicate. EXCEPTION: Slab-on-grade basement floors may be used when the slab performance risk evaluation is low or moderate and sufficient documentation is provided by the engineer of record to substantiate the performance risk assessment. Such assessment shall include but not be limited to consideration of all of the following factors: geologic structure; soil and bedrock profile and profile variability; material type and engineering properties of materials below the slab; swell tests or suction tests; depth and magnitude of moisture increase; existing and anticipated ground water conditions; location of any nearby surface water sources; type of basement; tolerable movement for the intended use; performance history and experience in the area; surface topography; previous and future grading; surface and subsurface drainage; and site landscaping, irrigation and vegetation. The slab performance risk shall be defined as shown in Table 401.4.5. TABLE 401.4.5 Swell Potential Descriptions and Corresponding Slab Performance Risk Categories Slab Performance Risk Category | Representative Percent Swell (500 psf Surcharge) | Representative Percent Swell (1000 psf Surcharge) Low | 0 to < 3 | 0 to < 2 Moderate | 3 to < 5 | 2 to < 4 High | 5 to < 8 | 4 to < 6 Very High | ≥ 8 | ≥ 6 Note: The representative percent swell values presented are not measured values; rather, they are a judgment of the swell of the soil and bedrock profile likely to influence performance. The building official may, however, determine that the documentation is insufficient to support the exception. Developers and builders or their representatives shall comply with the disclosure to purchaser requirements set forth in Section 6-6.5-101, C.R.S. In addition, prior to issuance of a certificate of occupancy for a residence with a slab-on-grade basement floor, a statement signed by the homebuyer shall be submitted wherein the homebuyer acknowledges to have read the soils report or summary soils report, understands the risks associated with a slab-on-grade basement floor, and chooses to accept those risks. If the buyer is unknown at the time of issuance of a certificate of occupancy, the statement shall be prepared and signed by the builder. In either case, the statement shall be recorded by the builder in the office of the county clerk and recorder. The builder shall pay the recording fee. The statement shall also include the name of the builder, the legal description of the property, and any other pertinent information required by the building official. New walls for basement finishes in existing buildings with existing slab on grade floors shall be provided with a slip joint (or float) in accordance with the soils report for the site to allow for vertical slab movement. In the absence of a soil report, a minimum of 1½" slip joint shall be provided. Doorways shall also be designed to allow vertical movement, and wall finish materials shall not extend to the floor. R401.4.5.1 Ventilation. Adequate underfloor ventilation systems shall be provided to ventilate underfloor areas when structural floor systems are required. Such systems shall be designed to provide at least one air change per hour, be controlled by a humidistat, and exhaust to the outside. EXCEPTIONS: 1. The building official may approve alternates to such requirements when sufficient documentation is provided by the engineer of record to substantiate his or her alternate method is at least the equivalent of that prescribed. 2. Ventilation is not required for spaces below noncombustible structural basement floors located below grade. R401.4.5.2 Underfloor grading. When structural basement floors are installed, a minimum of 18" of clear space is required below untreated wood floor joists and any wood girders or beams. Where steel or concrete beams or joists are used, the minimum clearance shall be as recommended by the soils engineer. The surface of the underfloor area shall be graded to a relatively flat plane to slope toward the sump pit, or toward drain systems installed to control free water in the underfloor space. The underfloor area shall not allow ponding of water. (Q) An Exception is hereby added to Subsection R408.4 to read as follows: EXCEPTION: Access is not required for spaces below noncombustible structural basement floors located below grade where there is no mechanical equipment. (R) Amend Table R702.7(2) to allow latex paint to be used as a Class III vapor retarder (S) Amend section R807 to read as follows: R807.1 Attic access. Buildings with attics shall have an attic access opening to attic areas that have a vertical height of 30 inches (762 mm) or greater over an area of not less than 30 square feet (2.8 m2). The vertical height shall be measured from the top of the ceiling framing members to the underside of the roof framing members. The rough-framed opening shall be not less than 22 inches by 30 inches (559 mm by 762 mm) and shall be located in a hallway or other location with ready access. Where located in a wall, the opening shall be not less than 22 inches wide by 30 inches high (559 mm wide by 762 mm high). Where the access is located in a ceiling, minimum unobstructed headroom in the attic space shall be 30 inches (762 mm) along at least one side above the access measured vertically from the bottom of ceiling framing members. See Section M1305.1.2 for access requirements where mechanical equipment is located in attics. (T) Delete Part IV - Energy Conservation (Chapter 11 Energy Efficiency) in its entirety. For energy code provisions, see the adopted Colorado Low Energy and Carbon Code. (U) Subsection M1403.1 Heat Pumps is hereby amended to read as follows: Electric heat pumps shall be tested in accordance with UL1995 or UL/CSA 60335-2-40. Electric heat pumps shall be installed at least twelve inches above grade or manufacturer installation requirements, whichever is greater. (V) Section M1502.4.2 is amended to read as follows: M1502.4.2 Duct installation. Exhaust ducts shall be supported at four foot (1219 mm) intervals and secured in place. The insert end of the duct shall extend into the adjoining duct or fitting in the direction of airflow. Exhaust duct joints shall be sealed in accordance with Section M1601.4.1. Ducts shall not be joined with screws or similar fasteners that protrude from into the inside of the duct. (W) Delete Section M1601.1.1 #7 in its entirety (X) Subsection M1804.2.5 Direct vent terminations is hereby amended to read as follows: Vent terminals for direct-vent appliances shall be installed eighteen inches above grade or in accordance with manufacturer installation requirements, whichever is greater. (Y) Delete Chapter 24 in its entirety. For fuel gas code provisions see the adopted International Fuel Gas Code. (Z) Section P2503.5.1 is amended to read as follows: P2503.5.1 Rough Plumbing. DWV systems shall be tested on completion of the rough piping installation by water or by air without evidence of leakage. (AA) A new Section P2903.11 Irrigation rain sensors is hereby added and will read as follows: P2903.11 Irrigation rain sensors. An approved rain sensor device shall be installed in an approved location for all new irrigation system permits. (BB) Subsection P2904 - Dwelling Unit Automatic Sprinkler System is hereby amended to read as follows: P2904.1 General The design and installation of automatic sprinkler systems shall be in accordance with NFPA 13D. All other language in Section P2904 is hereby deleted. (CC) Subsection P2906.4 Water service pipe is hereby amended by adding the following sentence: P3101.1 Roof extension. All vent pipes which extend through a roof shall be terminated at least 12 inches above the roof, except where a roof is to be used for any purpose other than weather protection, the vent extensions shall be run at least 7 feet (2134 mm) above the roof. (DD) Section P3008 is deleted in its entirety. (EE) Subsection P3104.4 Vertical rise of vent is hereby amended to read as follows: P3104.4 Vertical rise of vent. Unless prohibited by structural conditions, every dry vent shall rise vertically to a minimum of 6 inches (152 mm) above the flood level of the highest trap or trapped fixture being vented. Vents that are less than 6 inches (152 mm) above the flood level rim of the fixture require approved drainage type fittings with slope back to the drain. (FF) Part VIII Electrical (Chapters 33 through 43) is hereby deleted in its entirety. For electrical code provisions see the adopted National Electrical Code.

(Ord. 1926 §12, 2011; Ord. 1953 §2, 2012; Ord. 1994 §9, 2014; Ord. 2012 §1, 2015; Ord. 2042 §8, 2017; Ord. No. 2093, § 1, 6-25-19; Ord. No. 2115, 2-25-20; Ord. No. 2205, 3-7-23; Ord. No. 2218, § 1, 8-22-23; Ord. No. 2221, § 1, 8-22-23; Ord. No. 2295, § 3, 2-24-26)

Ask a question about Broomfield law

Corpus searches the Broomfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.