§ 18.12.030 — Areas of shallow flooding

Municipal Code of the Town of Castle Rock, Colorado (Codified through Ordinance No. 2026-014, enacted May 5, 2026 (Supp. No. 63)) · Castle Rock Municipal Code § 18.12.030

Corpus is an independent public-information project, not the official City of Castle Rock website. Stable reference: corpuslaw.us/code/8c8e95f8-0161-49e8-9a29-6977b968cc7a

18.12.030 - Areas of shallow flooding.

Located within the Special Flood Hazard Area established in Section 18.08.020, CRMC, are areas designated as shallow flooding (AO/AH Zones). These areas have special flood hazards associated with base flood depths of one to three feet where a clearly defined channel does not exist, where the path of flooding is unpredictable and where velocity flow may be evident. Such flooding is characterized by ponding or sheet flow; therefore, the following provisions apply: A. Residential construction. All new construction and substantial improvements of residential structures must have the lowest floor (including basement) elevated above the highest adjacent grade at least two feet above the depth number specified in feet on the community's FIRM (at least four feet if no depth number is specified). Upon completion of the structure, the elevation of the lowest floor, including basement, shall be certified by a registered Colorado professional engineer, architect or land surveyor. Such certification shall be submitted to the Floodplain Administrator. B. Nonresidential construction. With the exception of critical facilities outlined in Section 18.12.080, CRMC, all new construction and substantial improvements of nonresidential structures must have the lowest floor (including basement) elevated above the highest adjacent grade at least two feet above the depth number specified in feet on the community's FIRM (at least four feet if no depth number is specified) or, together with attendant utility and sanitary facilities, be designed so that the structure is watertight to at least one foot above the base flood level with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. A registered Colorado professional engineer or architect shall submit a certification to the Floodplain Administrator that the standards of this Section, as proposed in Section 18.10.030, CRMC, are satisfied. Within areas of shallow flooding, adequate drainage paths around structures on slopes are required to guide floodwaters around and away from proposed structures.

(Ord. 2013-38 §1, 2013)

Ask a question about Castle Rock law

Corpus searches the Castle Rock sections it holds and shows the ones that match, with their citations. Free, no sign-in.