§ 12-3-301 — General standards for residential development
Municipal Code, City of Centennial, Colorado (Supp. 26 Update 4: codified through Ordinance of August 18, 2026 (online updated October 28, 2026)) · Centennial Municipal Code § 12-3-301
Corpus is an independent public-information project, not the official City of Centennial website. Stable reference: corpuslaw.us/code/5bf14f3b-55ad-4548-bbe3-819517bf7954
Sec. 12-3-301. - General standards for residential development.
A. Generally. This Section sets out the standards for redevelopment, new development, and expansion of existing residential development in the NC and NI districts. If a building or building expansion beyond the existing foundation is proposed in the NC5, NC6, NC9, NC12, or NI district, and it does not comply with one or more of the setback standards of Table 12-3-301A, Residential Lot and Building Standards, then the corresponding setback standards of Section 12-3-302, Alternative Setback Standards for Single-Family Detached Homes; or Section 12-3-303, Alternative Setback Standards for Single Family Attached Homes; or Section 12-3-304, Alternative Setback Standards for Condominium and Alternative Land Ownership Patterns; are applied instead of the standards of this Section. For side setbacks, if a proposed expansion would be set back less than a minimum side setback and/or would make the entire building set back less than the total side setback, then the alternative development standards for the side setback where the expansion is proposed applies. Design Requirements for Residential Development are set out in Article 4, Form and Design Standards. B. Standards. The lot and building standards for residential development are set out in Table 12-3-301A, Residential Lot and Building Standards. The lot width and setbacks set out in the table are illustrated in Figure 12-3-301, Single-Family Lot Widths and Setbacks, and measured as set out in Section 12-3-201, Lot Area; Section 12-3-203, Lot Width; Section 12-3-202, Setbacks; Section 12-3-204, Height; and Section 12-3-205, Building Coverage and Building Coverage Ratio. C. Building Height. The permitted building heights are included in Table 12-3-301A, Residential Lot and Building Standards, with reference to Table 12-3-301B, Neighborhood Infill Subdistricts. Table 12-3-301B identifies the permitted range of building heights within the applicable subdistrict, including maximum heights. The NI subdistricts support a range of building heights to prioritize compatibility, with intervals of five (5) feet in permitted heights (e.g., NI SFD/SFA 35 or NI SFA 45 ). D. Dove Valley Residential Overlay District. Properties zoned RU within the Dove Valley Residential Overlay District must implement a Traditional Neighborhood Development (TND) through the NI TND zone district standards. A TND within the Dove Valley Residential Overlay District must provide a minimum of three (3) housing types as set out in Section 12-3-403, Mix of Housing Types, within the NI TND zone district, with a minimum percentage of any one (1) housing type being twenty (20) percent. E. Condominiums and Common Maintenance Communities. Where buildings are part of a common maintenance community in which either common open space separates buildings and/or separates lot lines from streets, or all land is owned by a condominium association: 1. The separation between buildings shall be at least two times the corresponding setback from Table 12-3-301A, Residential Lot and Building Standards. 2. Setbacks in relation to the street shall be measured as: i. The shortest distance from the front elevation of the building to the back of the sidewalk; or ii. If no sidewalk is present, the back of the curb; or iii. If no sidewalk or curb is present, the edge of pavement; but iv. Any such measurement shall not permit buildings to be constructed in public rights-of-way. 3. The front setback of buildings that face parking lots or internal drives shall be measured as if the parking lot or internal drive pavement is a street. 4. Building coverage ratio may be measured by dividing the total of all building footprints in the development by the total land area of the development. F. Bufferyards. New development and redevelopment shall be configured to provide the bufferyards required by Section 12-8-406, District Boundary Bufferyards. Table 12-3-301A Residential Lot and Building Standards Zone District | Permitted Housing Typologies | Minimum Lot Area | Minimum Lot Width | Front Setback1 | Street Side Setback (SS)1 | Interior Side (S1 or S2)1 | Total Side Setback (S1 + S2)1 | Rear Setback1 | Building Coverage Ratio | Height | Landscape Surface Ratio (LSR) NC 2A | Single Family Detached | See Table 12-2-201B | See Table 12-2-201B | 50 ft. | 50 ft. | 25 ft. | 80 ft. | 25 ft. | 20% | 35 ft. | N/A NC 18 | Single Family Detached | See Table 12-2-201B | See Table 12-2-201B | 25 ft. | 25 ft. | 20 ft. | 50 ft. | 25 ft. | 20% | 30 ft. NC 12 | Single Family Detached | See Table 12-2-201B | See Table 12-2-201B | 25 ft. | 15 ft. | 8 ft. | 20 ft. | 20 ft. | 25% | 30 ft. NC 9 | Single Family Detached | See Table 12-2-201B | See Table 12-2-201B | 20 ft. | 10 ft. | 5 ft. | 16 ft. | 20 ft. | 30% | 30 ft. NC 6 | Single Family Detached | See Table 12-2-201B | See Table 12-2-201B | 20 ft. | 10 ft. | 5 ft. | 12 ft. | 20 ft. | 37% | 30 ft. NC 5 | Single Family Detached | See Table 12-2-201B | See Table 12-2-201B | 15 ft. | 10 ft. | 5 ft. | 10 ft. | 15 ft. | 42% | 30 ft. NI 18 | Single Family Detached | See Table 12-2-201C | See Table 12-2-201B | 25 ft. | 20 ft. | 8 ft. | 20 ft. | 20 ft. | 45% | 35 ft. NI 8 | Single Family Detached | See Table 12-2-201C | See Table 12-2-201B | 25 ft. | 10 ft. | 8 ft. | 20 ft. | 20 ft. | 40% | 35 ft. NI SFD/SFA | Single Family Detached | 4,000 sf. per unit | 50 ft. | 5 feet if parking is rear accessed; 20 ft. if parking is front accessed or shared parking lot 1 | 10 ft. 1 | 5 ft. 1 | 10 ft. 1 | 5 feet if parking is rear accessed; 15 ft. if parking is front accessed or shared parking lot 1 | 45% | See Table 12-3-301B | 5% Single Family Detached - Cottage | Minimum 1,000 sf., Maximum 3,000 sf. | 25 ft. | 15 ft. 1 | 10 ft. 1 | 5 ft. 1 | 10 ft. 1 | 15 ft. 1 | 60% | See Table 12-3-301B Single Family Attached - Duplex | 2,000 sf. per unit | 22 ft. if parking is rear accessed; 25 feet if parking is front accessed or shared parking lot | 5 ft. if parking is rear accessed; 20 feet if parking is front accessed or shared parking lot 1 | 10 ft. 1 | 0 ft. | 0 ft. if attached, 6 ft. if buildings separated 1 | 5 ft. if parking is rear accessed; 15 feet if parking is front accessed or shared parking lot 1 | N/A | See Table 12-3-301B NC SFA | Single Family Attached | See Table 12-2-201B | See Table 12-2-201B | 5 ft. if parking is rear accessed or shared parking lot; 20 ft. if parking is front accessed | 10 ft. | 0 ft. | 0 ft. if attached, 6 ft. if buildings separated | 20 ft. if parking is rear accessed; 10 ft. if parking is front accessed or shared parking lot | 75% | Existing Building Height | N/A NI SFA | Single Family Attached - Duplex | 2,000 sf. per unit | 22 ft. if parking is rear accessed; 25 feet if parking is front accessed or shared parking lot | 5 ft. if parking is rear accessed; 20 feet if parking is front accessed or shared parking lot 1 | 10 ft. 1 | 0 ft. | 0 ft. if attached, 6 ft. if buildings separated 1 | 5 ft. if parking is rear accessed; 15 feet if parking is front accessed or shared parking lot 1 | N/A | See Table 12-3-301B | 5% Single Family Attached - Townhome | 1,000 sf. per unit | 22 ft. if parking is rear accessed; 25 feet if parking is front accessed or shared parking lot | 5 ft. if parking is rear accessed; 20 feet if parking is front accessed or shared parking lot 1 | 10 ft. 1 | 0 ft. | 0 ft. if attached, 6 ft. if buildings separated 1 | 5 ft. if parking is rear accessed; 15 feet if parking is front accessed or shared parking lot 1 | N/A | See Table 12-3-301B NI SFA/MF | Single Family Attached - Duplex | 2,000 sf. per unit | 22 ft. if parking is rear accessed; 25 feet if parking is front accessed or shared parking lot | 5 ft. if parking is rear accessed; 20 feet if parking is front accessed or shared parking lot 1 | 10 ft. 1 | 0 ft. | 0 ft. if attached, 6 ft. if buildings separated 1 | 5 ft. if parking is rear accessed; 15 feet if parking is front accessed or shared parking lot 1 | N/A | See Table 12-3-301B | 5% Single Family Attached - Townhome | 1,000 sf. per unit | 22 ft. if parking is rear accessed; 25 feet if parking is front accessed or shared parking lot | 5 ft. if parking is rear accessed; 20 feet if parking is front accessed or shared parking lot 1 | 10 ft. 1 | 0 ft. | 0 ft. if attached, 6 ft. if buildings separated 1 | 5 ft. if parking is rear accessed; 15 feet if parking is front accessed or shared parking lot 1 | N/A | See Table 12-3-301B Multifamily | 1 acre per Parcel Proposed for Development | N/A | 20 ft. 1 | 15 ft. 1 | 15 ft. 1 | 30 ft. 1 | 20 ft. 1 | N/A | See Table 12-3-301B NC MF | Multifamily | Existing | Existing | Existing | Existing | Existing | Existing | Existing | Existing | Existing | N/A NI TND | Single Family Detached | 4,000 sf. per unit | 50 ft. | 5 ft. if parking is rear accessed; 20 feet if parking is front accessed or shared parking lot 1 | 10 ft. 1 | 5 ft. 1 | 10 ft. 1 | 5 ft. if parking is rear accessed; 15 feet if parking is front accessed or shared parking lot 1 | 45% | See Table 12-3-301B | 5% Single Family Detached - Cottage | Minimum 1,000 sf., Maximum 3,000 sf. | 25 ft. | 15 ft. 1 | 10 ft. 1 | 5 ft. 1 | 10 ft. 1 | 15 ft. 1 | 60% | See Table 12-3-301B Single Family Attached - Duplex | 2,000 sf. per unit | 22 ft. if parking is rear accessed; 25 feet if parking is front accessed or shared parking lot | 5 ft. if parking is rear accessed; 20 feet if parking is front accessed or shared parking lot 1 | 10 ft. 1 | 0 ft. | 0 ft. if attached, 6 ft. if buildings separated 1 | 5 ft. if parking is rear accessed; 15 feet if parking is front accessed or shared parking lot 1 | N/A | See Table 12-3-301B Single Family Attached - Townhome | 1,000 sf. per unit | 22 ft. if parking is rear accessed; 25 feet if parking is front accessed or shared parking lot | 5 ft. if parking is rear accessed; 20 feet if parking is front accessed or shared parking lot 1 | 10 ft. 1 | 0 ft. | 0 ft. if attached, 6 ft. if buildings separated 1 | 5 ft. if parking is rear accessed; 15 feet if parking is front accessed or shared parking lot 1 | N/A | See Table 12-3-301B Multifamily | 1 acre per Parcel Proposed for Development | N/A | 20 ft. 1 | 15 ft. 1 | 15 ft. 1 | 30 ft. 1 | 20 ft. 1 | N/A | See Table 12-3-301B 1 Buildings or portions thereof within 50 feet of NC, NI-8, or NI-18 zone districts shall be setback an additional one (1) foot for every one (1) foot in building height over 35 feet. Table 12-3-301B Neighborhood Infill Subdistricts NI Subdistrict | Maximum Height (feet) NI SFD/SFA 30 | 30 NI SFD/SFA 35 | 35 NI SFD/SFA 40 | 40 NI SFD/SFA 45 | 45 NI SFD/SFA 50 | 50 NI SFA 30 | 30 NI SFA 35 | 35 NI SFA 40 | 40 NI SFA 45 | 45 NI SFA 50 | 50 NI SFA/MF 30 | 30 NI SFA/MF 35 | 35 NI SFA/MF 40 | 40 NI SFA/MF 45 | 45 NI SFA/MF 50 | 50 NI SFA/MF 55 | 55 NI SFA/MF 60 | 60 NI SFA/MF 65 | 65 NI SFA/MF 70 | 70 NI TND 30 | 30 NI TND 35 | 35 NI TND 40 | 40 NI TND 45 | 45 NI TND 50 | 50 NI TND 55 | 55 NI TND 60 | 60 Figure 12-3-301 Single-Family Detached Lot Widths and Setbacks [image omitted; see the official code]
(Ord. 2024-O-14 §§21—23; Ord. 2025-O-12 §7)
Ask a question about Centennial law
Corpus searches the Centennial sections it holds and shows the ones that match, with their citations. Free, no sign-in.
