Sec. 12-3-303. - Alternative Standards for Single-Family Attached Homes.

A. Generally. The standards of this Section apply to the expansion of existing attached single-family home buildings in the NCSFA District beyond the extent of their original foundations or existing building height. Standards for new development, redevelopment, and reconstruction of buildings are provided in Section 12-3-301, General Standards for Residential Development. 1. Reconstruction. Notwithstanding the standards of this Subsection, any attached single-family building in an NCSFA District may be reconstructed to its original configuration and height, pursuant to Article 12, Nonconformities. B. Alternative Standards for Building Height. Building height shall not be increased to more than the greater of: 1. Ten percent more than the existing height of the building; or 2. Thirty-five feet. C. Alternative Building Setback Standards; All Setbacks. Alternative development standards shall be applied only if it is demonstrated by the applicant to the City's reasonable satisfaction that the standards of the applicable subsection of this Section are met, and: 1. The proposed construction does not interfere with planned expansion of right-of-way, and if right-of-way expansion is planned, the encroachment is evaluated as if the right-of-way has been expanded; 2. The proposed construction does not result in interference with a utility easement; 3. Drainage onto abutting properties, attached or neighboring dwelling units, or rights-of-way is not significantly altered, and drainage patterns are not substantially changed, when compared to the condition before the proposed development; 4. The proposed construction does not result in a nonconformity with respect to the building code on either the lot proposed for development, abutting properties, or nearby buildings; 5. If the parcel that abuts the improvement is used for residential purposes, the proposed construction is built to building code standards (e.g., fire ratings) that would allow construction of the abutting lot (or closest building to the improvement) to be built to the same standard with the same distance of encroachment; 6. The proposed construction does not substantially increase any existing degree of obstruction of the solar access of abutting property, neighboring buildings, or other attached units that are not owned by the applicant; 7. The proposed construction conforms to building coverage limitations set out in Section 12-3-303, General Standards for Attached Single-Family Homes; and 8. The proposed construction does not reduce the area provided for parking to fewer spaces than are required by Division 5-2, Parking and Loading Calculations. D. Alternative Building Setback Standards; Front Setbacks. Front setbacks may be reduced from the standards set out in Table 12-3-301A, Residential Lot and Building Standards, if compliance with all of the requirements of subsection C., above, and any of the following options is demonstrated by the applicant to the City's reasonable satisfaction: 1. Option #1. If the existing building does not encroach into the required setback, but the proposed improvement does: a. The proposed construction does not involve the destruction of a healthy, mature tree; and b. The encroachment will not reduce the depth of a driveway to: i. Less than 20 feet in length to the edge of the sidewalk; or ii. Less than 22 feet in length to the edge of pavement if no sidewalk is either provided or planned; and c. If the encroachment is more than 10 feet wide (measured parallel to the front building line), then it is screened from view from the public right-of-way by a canopy tree or evergreen tree; or 2. Option #2. If the existing building encroaches upon the required setback as of the effective date, and: a. The proposed construction does not involve the destruction of a healthy, mature tree; b. The proposed construction will not reduce the depth of a driveway to: i. Less than 20 feet in length to the edge of the sidewalk; or ii. Less than 22 feet in length to the edge of pavement if no sidewalk is either provided or planned; and c. The proposed construction will be set back not less than 85 percent of the setback of the existing building; and d. The proposed construction will not create the appearance of a monolithic building frontage by substantially reducing the articulation of the building as viewed from the street; or 3. Option #3. If the existing building fronts on a mews or other permanent open space that is not less than 50 feet wide, the front setback may be reduced by up to 25 percent. E. Alternative Building Setback Standards; Interior Side Setbacks. Interior side setbacks may be reduced from the standards set out in Table 12-3-301A, Residential Lot and Building Standards, if compliance with all of the requirements of subsection C., above, and any of the following options is demonstrated by the applicant to the City's reasonable satisfaction: 1. Option #1. The proposed interior side setback is equal to not more than the average actual side building setback of comparable attached single-family residential buildings in the same development on the same block; or 2. Option #2. The proposed interior side setback is not less than 60 percent of the required interior side setback, or three feet, whichever is a larger setback, and: a. Limit of Encroachment. i. If the lot that abuts the proposed building expansion is used for residential purposes and is not in the same development as the lot proposed for development, then: a. Building expansions that are 12 feet in height (measured from the average grade across the side of the proposed construction facing the abutting lot) or less are set back at least 42 inches from the side lot line; and b. Building expansions that are more than 12 feet in height (measured from the average grade across the side of the proposed construction facing the abutting lot) are set back at least five feet from the side lot line. ii. If the lot that abuts the proposed building expansion is used for nonresidential purposes or permanent open space that is at least 20 feet in width, then the building expansion is set back at least 42 inches from the side lot line. b. Horizontal Dimension. The building expansion, combined with the existing building, creates a horizontal dimension of not more than 50 feet without an offset in the building wall of at least three feet. c. Windows. The building expansion does not include a window that is located directly across from another window on a residential building that is closer than 20 feet away, unless: i. The window is on the first floor and an opaque fence is installed between the two buildings to a height of six feet; or ii. The window is not operational and is made of glass block or frosted glass. F. Alternative Building Setback Standards; Rear Setbacks. Rear setbacks may be reduced from the standards set out in Table 12-3-301A, Residential Lot and Building Standards, if compliance with all of the requirements of subsection C., above, and any of the following options is demonstrated by the applicant to the City's reasonable satisfaction: 1. Option #1. Rear setbacks may be reduced on any lot if it is demonstrated that the proposed rear building setback is equal to not more than 10 percent less than the average actual setback of the other attached single-family homes that are located in the same development within 150 feet of the building proposed for expansion; or 2. Option #2. Rear setbacks may be reduced on lots with rear lot lines that abut permanent open space, and on through lots with fences or walls that screen rear yards from arterials and collectors, according to the following standards: a. For construction, or portions of construction, that is 12 feet or less in height (measured from the average grade across the side of the proposed construction facing the rear lot line), the rear setback may be reduced by up to 50 percent if it is demonstrated that there is at least 100 square feet of ground-level landscaped area behind the building with no dimension less than 8 feet, and: i. The proposed construction will not create the appearance of a monolithic building by substantially reducing the articulation of the building as viewed from abutting property, open space, or public rights-of-way; or ii. The proposed construction is located behind an opaque fence or garden wall that is at least five feet in height, and one evergreen or canopy tree is planted (or retained) in the rear yard for each 12 feet of width of the encroaching portion of the proposed construction; or b. For construction, or portions of construction, that is more than 12 feet in height (measured from the average grade across the side of the proposed construction facing the rear lot line), the rear setback may be reduced up to 30 percent if it is demonstrated that the standards of subsection G.2.a., above, are met, and: i. The building will not have a three-story expression (e.g., two stories above a walk-out basement) as a result of the proposed construction; or ii. A building that has an existing three-story expression will be modified in a way that mitigates the appearance of the three-story mass by substantially articulating the back wall of the building when compared to its existing condition; or 3. Option #3. Rear setbacks may be reduced on lots with rear lot lines that abut alleys if it is demonstrated by the applicant to the City's reasonable satisfaction that: a. The reduction of the rear setback would not reduce the available turning radius from the alley to the garage on the lot proposed for development or any other lot to less than 25 feet; and b. The proposed setback does not interfere with the safe use of the alley by blocking sight lines between garages and the paved area of the alley; and c. There is at least 100 square feet of ground-level landscaped area being the building with no dimension less than 8 feet.

(Ord. 2024-O-14 §§27, 28)

Ask a question about Centennial law

Corpus searches the Centennial sections it holds and shows the ones that match, with their citations. Free, no sign-in.