§ 18-15-40 — Design Method I
Municipal Code, City of Centennial, Colorado (Supp. 26 Update 4: codified through Ordinance of August 18, 2026 (online updated October 28, 2026)) · Centennial Municipal Code § 18-15-40
Corpus is an independent public-information project, not the official City of Centennial website. Stable reference: corpuslaw.us/code/213eb34e-c880-4a75-a7e6-0f49dd9940a3
Sec. 18-15-40. - Design Method I.
(a) Generally. (1) Under this Article, this method requires the designer or architect to follow the construction requirements for all exterior façade elements as listed in the tables below: Table 18-15-40(1): Minimum residential construction requirements in the 55 DNL noise contour zone and buffer zone for noise sensitive uses as required in Chapter 12, Article 9, of this Code. Façade Element | Minimum Requirement 1 Exterior walls Structural | 2-inch by 4-inch wood or metal studs Insulation | R-19 insulation with full cavity fill Interior gypsum | Blown cellulose Exterior applications | 1-layer of ½-inch or ⅝-inch gypsum 7/16 -inch OSB or plywood and stucco, siding, brick or stone Basement walls | Basements are excluded, as long as basement windows and sliding glass doors have minimum STC ratings of 32. Exterior floors | Normal construction, except for full joist fill insulation Roof and exterior ceilings | Minimum attic insulation shall be R-49. Vaulted roof/ceiling structures are allowed, coffered ceilings are acceptable. For vaulted ceilings the minimum joist or truss depth is 14 inches. Use of vaulted ceilings increases required STC rating of windows above those listed. Doors Exterior swing doors | Solid core doors with jamb seals and sweeps, glazing in doors shall have minimum STC rating of 32 Sliding glass doors | Minimum STC rating of 32 Windows | Minimum STC rating of 32 HVAC and appliance venting | Shall be as specified in Section 18-15-80 1 Minimum twenty-five (25) OITL decibels. Table 18-15-40(2): Minimum residential construction requirements in the 60 and 65 DNL noise contour zones and RDA for noise sensitive uses as required in Chapter 12, Article 9, of this Code. Façade Element | Minimum Requirement 1 Exterior walls Structural | 2-inch by 6-inch wood or metal studs Insulation | R-19 insulation with full cavity fill Interior gypsum | 2-layers of ½-inch or ⅝-inch gypsum Exterior applications | 2-layers of ½-inch or ⅝-inch gypsum 7/16 -inch OSB or plywood and stucco, siding, brick or stone Basement walls | Basements are excluded, as long as basement windows and sliding glass doors have minimum STC ratings of 34. Exterior floors | Normal construction, except for full joist fill insulation Roof and exterior ceilings | Minimum attic insulation shall be R-49. Joist type vaulted roof/ceiling structures are not allowed, coffered ceilings are acceptable. Truss type vaulted ceilings are allowed and shall have a minimum truss depth of 36 inches. Use of vaulted ceilings increases required STC rating of windows above those listed. Doors Exterior swing doors | Solid core doors with jamb seals and sweeps, glazing in doors shall have minimum STC rating of 34 Sliding glass doors | Minimum STC rating of 34 Windows | Minimum STC rating of 34 HVAC and appliance venting | Shall be as specified in Section 18-15-80 1 Minimum thirty (30) OITL decibels. Table 18-15-40(3): Minimum commercial construction requirements in the 55, 60 and 65 DNL noise contour zones and buffer zone and RDA for noise sensitive uses as required in Chapter 12, Article 9, of this Code. Façade Element | Minimum Requirement Exterior walls | Typical commercial construction Roof and exterior ceilings | Typical commercial roof/ceiling construction Doors | Typical commercial doors Windows | If window area in a specific room is less than 20% of the total area minimum STC rating of 32, if window area in a specific room is greater than 20% of the total area minimum STC rating of 34 HVAC and appliance venting | None (b) Construction. All exterior walls, roofs and exposed floors shall be of airtight construction. Any penetrations of exterior walls or roofs by pipes, ducts or conduits shall be sealed airtight as required for joints. Door and window openings in exterior walls shall be flashed all around with an approved vapor barrier and sealed to prevent air infiltration. Sill sealant shall be used to prevent air infiltration at all base plates of exterior walls. Attic and crawl space vents shall not exceed minimums specified by ordinance. Crawl space vents shall be baffled as shown in Section 18-15-90. See Section 18-15-80 for building mechanical systems.
(Ord. 2018-O-05, §4)
Ask a question about Centennial law
Corpus searches the Centennial sections it holds and shows the ones that match, with their citations. Free, no sign-in.
