For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18-15-60 — Design Method III

Municipal Code, City of Centennial, Colorado (Supp. 26 Update 4: codified through Ordinance of August 18, 2026 (online updated October 28, 2026)) · Centennial Municipal Code § 18-15-60

Corpus is an independent public-information project, not the official City of Centennial website. Stable reference: corpuslaw.us/code/8cd7001c-8a26-47fe-b55f-5a99aa072a0d

Sec. 18-15-60. - Design Method III.

(a) Generally. (1) Under this Article, this method allows compliance with the aircraft noise reduction criteria specified in Section 18-15-10 to be verified by actual sound level measurement. (b) Noise level reduction requirements. (1) All structures shall be designed and constructed so that the exterior shell of the structure (windows closed) provides measured noise level reduction equal to or greater than the minimum values listed in Section 18-15-10. (c) Testing. (1) Sound level measurements shall be conducted in accordance with ASTM E 966 (current revision at time of plans submittal), "Field Measurement of Airborne Sound Insulation of Building Facades and Facade Elements." The OITL shall be calculated using ASTM E 1332 (current revision at time of plans submittal), "Classification for Determination of Outdoor-Indoor Transmission Class". (2) The field test report shall be certified by an acoustical engineer, licensed as a professional engineer in the State of Colorado, whom is also a practicing acoustical engineer.

(Ord. 2018-O-05, §4)

Ask a question about Centennial law

Corpus searches the Centennial sections it holds and shows the ones that match, with their citations. Free, no sign-in.