§ 10-104 — Specific standards for mixed-use development in floodways
Fort Collins Municipal Code (Supp. No. 156, Update 2: codified through Ordinance No. 122, 2026, enacted September 15, 2026) · Fort Collins Municipal Code § 10-104
Corpus is an independent public-information project, not the official City of Fort Collins website. Stable reference: corpuslaw.us/code/f67d9573-a839-4a66-9cf2-e8895e8d418f
Sec. 10-104. - Specific standards for mixed-use development in floodways.
In addition to complying with all other applicable provisions of this Article, all mixed-use development in the floodway of a FEMA basin floodplain or a City basin floodplain shall comply with the following provisions. If there is any conflict between any of the following provisions and any other provision of this Article, the more restrictive provision shall control. (1) New construction. Construction of a new mixed-use structure is prohibited. (2) Addition. a. Addition to a mixed-use structure for residential use is prohibited. b. Addition to the nonresidential use portions of a mixed-use structure is allowed, provided that all applicable requirements, including, but not limited to, the requirements of § 10-45 and the requirements of § 10-37, are met. c. In FEMA basin floodplains, any new addition must either be designed and certified by a Colorado registered professional engineer and/or architect as being a structurally independent addition or the value of the addition shall be included in the determination of substantial improvement. d. In City basin floodplains, the value of the addition shall not be included in the determination of substantial improvement so long as the addition meets the regulatory flood protection standard set forth in § 10-37. e. For an addition to a mixed-use structure, compliance with the requirements of § 10-38 may be substituted for compliance with the applicable requirements of Subsection 10-37(b). f. No new basement may be constructed below the regulatory flood protection elevation in an addition to a mixed-use structure. (3) Remodeling and repairs. a. Remodeling or repair of a mixed-use structure is allowed, provided that, after completion of any substantial improvement, all applicable requirements, including, but not limited to, the requirements of § 10-37, are met. b. For remodeling or repair of a mixed-use structure, in the event that all residential use is on a floor completely above the regulatory flood protection elevation, compliance with the requirements of § 10-38 may be substituted for compliance with the applicable requirements of Subsection 10-37(b). c. No new basement may be constructed below the regulatory flood protection elevation in any remodeling or repair of a mixed-use structure. d. A nonconforming basement below the regulatory flood protection elevation may remain in connection with the remodeling or repair of a mixed-use structure, provided that, after completion of any substantial improvement: 1. All residential use is on a floor completely above the regulatory flood protection elevation; and 2. All applicable requirements, including, but not limited to, the requirements of § 10-38, are met. (4) Redevelopment. a. Redevelopment of a mixed-use structure is allowed, provided that all applicable requirements, including, but not limited to, the requirements of § 10-37, are met. b. For a redevelopment of a mixed-use structure, in the event that all residential use is on a floor completely above the regulatory flood protection elevation, compliance with the requirements of § 10-38 may be substituted for compliance with the applicable requirements of Subsection 10-37(b). c. No new basement may be constructed below the regulatory flood protection elevation in any redevelopment of a mixed-use structure. d. A nonconforming basement below the regulatory flood protection elevation may remain in connection with the redevelopment of a mixed-use structure, provided that: 1. All residential use is on a floor completely above the regulatory flood protection elevation; and 2. All applicable requirements, including, but not limited to, the requirements of § 10-38, are met. (5) Attached garages. a. Addition of a new attached garage to a mixed-use structure is allowed, provided that all applicable requirements, including, but not limited to, the requirements of § 10-45 and the requirements of § 10-37, are met by the attached garage. b. In FEMA basin floodplains, any new addition must either be designed and certified by a Colorado registered professional engineer and/or architect as being a structurally independent addition or the value of the addition shall be included in the determination of substantial improvement. c. In City basin floodplains, the value of the addition shall not be included in the determination of substantial improvement so long as the addition meets the regulatory flood protection standard set forth in §10-37. d. For a garage attached to a mixed-use structure, compliance with the requirements of § 10-38 or the requirements of § 10-39 may be substituted for compliance with the applicable requirements of Section 10-37(b). (6) Accessory structures. a. Construction of a new accessory structure or addition to an accessory structure is allowed, provided that all applicable requirements, including, but not limited to, the requirements of § 10-45 and the requirements of § 10-37, are met by the accessory structure. b. In FEMA basin floodplains, any new addition must either be designed and certified by a Colorado registered professional engineer and/or architect as being a structurally independent addition or the value of the addition shall be included in the determination of substantial improvement. c. In City basin floodplains, the value of the addition shall not be included in the determination of substantial improvement so long as the addition meets the regulatory flood protection standard set forth in § 10-37. d. Remodeling and repair of an accessory structure is allowed, provided that, after completion of any substantial improvement, all applicable requirements, including, but not limited to, the requirements of § 10-37, are met. e. Redevelopment of an accessory structure is allowed, provided that all applicable requirements, including, but not limited to, the requirements of § 10-37, are met. f. For an accessory structure, compliance with the requirements of § 10-38 or the requirements of § 10-39 may be substituted for compliance with the applicable requirements of Subsection 10-37(b). g. No new basement may be constructed below the regulatory flood protection elevation in any accessory structure. h. A nonconforming basement below the regulatory flood protection elevation may remain in an accessory structure, provided that, after completion of any substantial improvement or redevelopment, all applicable requirements, including, but not limited to, the requirements of § 10-38, are met. (7) Floodway modification. Floodway modification is prohibited unless all applicable requirements, including, but not limited to, the requirements of § 10-45, are met. (8) Critical facilities. Critical facilities are prohibited.
(Ord. No. 37, 2005, 3-15-05; Ord. No. 015, 2007 § 18, 2-20-07; Ord. No. 160, 2013, § 14, 11-19-13; Ord. No. 039, 2022, § 10, 4-19-22)
Ask a question about Fort Collins law
Corpus searches the Fort Collins sections it holds and shows the ones that match, with their citations. Free, no sign-in.
