§ 10-110 — Specific standards for mixed-use development in flood fringe
Fort Collins Municipal Code (Supp. No. 156, Update 2: codified through Ordinance No. 122, 2026, enacted September 15, 2026) · Fort Collins Municipal Code § 10-110
Corpus is an independent public-information project, not the official City of Fort Collins website. Stable reference: corpuslaw.us/code/26250708-b891-4baa-8f00-d707ce0c6b46
Sec. 10-110. - Specific standards for mixed-use development in flood fringe.
In addition to complying with all other applicable provisions of this Article, all mixed-use development in the flood fringe of a FEMA basin floodplain or a City basin floodplain shall comply with the following provisions unless removed from the flood fringe by approval of a LOMR in accordance with § 10-113. If there is any conflict between any of the following provisions and any other provision of this Article, the more restrictive provision shall control. (1) New construction. a. Construction of a new mixed-use structure is allowed, provided that all applicable requirements, including, but not limited to, the requirements of § 10-37, are met. b. For a new mixed-use structure, in the event that all residential use is on a floor completely above the regulatory flood protection elevation, compliance with the requirements of § 10-38 may be substituted for compliance with the applicable requirements of Subsection 10-37(b). c. A new basement may be constructed below the regulatory flood protection elevation in a new mixed-use structure, provided that: 1. All residential use is on a floor completely above the regulatory flood protection elevation; and 2. All applicable requirements, including, but not limited to, the requirements of § 10-38, are met. (2) Additions. a. Addition to a mixed-use structure is allowed, provided that all applicable requirements, including, but not limited to, the requirements of § 10-37, are met. b. In FEMA basin floodplains, any new addition must either be designed and certified by a Colorado registered professional engineer and/or architect as being a structurally independent addition or the value of the addition shall be included in the determination of substantial improvement. c. In City basin floodplains, the value of the addition shall not be included in the determination of substantial improvement so long as the addition meets the regulatory flood protection standard set forth in §10-37. d. For an addition to a mixed-use structure, in the event that all residential use is on a floor completely above the regulatory flood protection elevation, compliance with the requirements of § 10-38 may be substituted for compliance with the applicable requirements of Subsection 10-37(b). e. A new basement may be constructed below the regulatory flood protection elevation in an addition to a mixed-use structure, provided that: 1. All residential use is on a floor completely above the regulatory flood protection elevation; and 2. All applicable requirements, including, but not limited to, the requirements of § 10-38, are met. (3) Remodeling and repairs. a. Remodeling and repair of a mixed-use structure is allowed, provided that all applicable requirements, including, but not limited to, the requirements of § 10-37, are met. b. For remodeling or repair of a mixed-use structure, in the event that all residential use is on a floor completely above the regulatory flood protection elevation, compliance with the requirements of § 10-38 may be substituted for compliance with the applicable requirements of Subsection 10-37(b). c. A new basement may be constructed below the regulatory flood protection elevation in connection with the remodeling or repair of a mixed-use structure, provided that: 1. All residential use is on a floor completely above the regulatory flood protection elevation; and 2. All applicable requirements, including, but not limited to, the requirements of § 10-38, are met. d. A nonconforming basement below the regulatory flood protection elevation may remain in connection with the remodeling or repair of a mixed-use structure, provided that, after completion of any substantial improvement: 1. All residential use is on a floor completely above the regulatory flood protection elevation; and 2. All applicable requirements, including, but not limited to, the requirements of § 10-38, are met. (4) Redevelopment. a. Redevelopment of a mixed-use structure is allowed, provided that all applicable requirements, including, but not limited to, the requirements of § 10-37, are met. b. For a redevelopment of a mixed-use structure, in the event that all residential use is on a floor completely above the regulatory flood protection elevation, compliance with the requirements of § 10-38 may be substituted for compliance with the applicable requirements of Subsection 10-37(b). c. A new basement may be constructed below the regulatory flood protection elevation in connection with the redevelopment of a mixed-use structure, provided that: 1. All residential use is on a floor completely above the regulatory flood protection elevation; and 2. All applicable requirements, including, but not limited to, the requirements of § 10-38, are met. d. A nonconforming basement below the regulatory flood protection elevation may remain in connection with the redevelopment of a mixed-use structure, provided that: 1. All residential use is on a floor completely above the regulatory flood protection elevation; and 2. All applicable requirements, including, but not limited to, the requirements of § 10-38, are met. (5) Attached garages. a. Addition of an attached garage to a mixed-use structure is allowed, provided that all applicable requirements, including, but not limited to, the requirements of § 10-37, are met by the attached garage. b. In FEMA basin floodplains, any new addition must either be designed and certified by a Colorado registered professional engineer and/or architect as being a structurally independent addition or the value of the addition shall be included in the determination of substantial improvement. c. In City basin floodplains, the value of the addition shall not be included in the determination of substantial improvement so long as the addition meets the regulatory flood protection standard set forth in §10-37. d. For a garage attached to a mixed-use structure, compliance with the requirements of § 10-38 or the requirements of § 10-39 may be substituted for compliance with the applicable requirements of Subsection 10-37(b). (6) Accessory structures. a. Construction of a new accessory structure or addition to an accessory structure is allowed, provided that all applicable requirements, including, but not limited to, the requirements of § 10-37, are met. b. In FEMA basin floodplains, any new addition must either be designed and certified by a Colorado registered professional engineer and/or architect as being a structurally independent addition or the value of the addition shall be included in the determination of substantial improvement. c. In City basin floodplains, the value of the addition shall not be included in the determination of substantial improvement so long as the addition meets the regulatory flood protection standard set forth in § 10-37. d. Remodeling and repair of an accessory structure is allowed, provided that, after completion of any substantial improvement, all applicable requirements, including, but not limited to, the requirements of § 10-37, are met. e. Redevelopment of an accessory structure is allowed, provided that all applicable requirements, including, but not limited to, the requirements of § 10-37, are met. f. For an accessory structure, compliance with the requirements of § 10-38 or the requirements of § 10-39 may be substituted for compliance with the applicable requirements of Subsection 10-37(b). g. A new basement may be constructed below the regulatory flood protection elevation in an accessory structure, provided that all applicable requirements, including, but not limited to, the requirements of § 10-38, are met. h. A nonconforming basement below the regulatory flood protection elevation may remain in an accessory structure, provided that, after completion of any substantial improvement or redevelopment, all applicable requirements, including, but not limited to, the requirements of § 10-38, are met. (7) Critical facilities. Critical facilities are prohibited.
(Ord. No. 37, 2005, 3-15-05; Ord. No. 160, 2013, § 20, 11-19-13; Ord. No. 039, 2022, § 13, 4-19-22)
Ask a question about Fort Collins law
Corpus searches the Fort Collins sections it holds and shows the ones that match, with their citations. Free, no sign-in.
