§ 18-8 — Mobile home installation standards and permits
Fort Collins Municipal Code (Supp. No. 156, Update 2: codified through Ordinance No. 122, 2026, enacted September 15, 2026) · Fort Collins Municipal Code § 18-8
Corpus is an independent public-information project, not the official City of Fort Collins website. Stable reference: corpuslaw.us/code/27132e34-6824-4d7e-a16a-7fcd6ff58a6c
Sec. 18-8. - Mobile home installation standards and permits.
(a) Approved Mobile Homes. No mobile home shall be installed or placed upon a mobile home lot after the effective date of this Chapter, unless such mobile home bears a label or has equivalent documentation certifying that the mobile home was constructed in accordance with the Federal Manufactured Home Construction and Safety Standards Act of 1974, or NFPA 501, ANSI 119.1, or equivalent. Mobile homes manufactured prior to such standards may be installed in the City subject to approval on an individual basis by the Building Official, upon finding that such mobile home is in a safe, sound physical condition and meets all other provisions of the standards specified in this Section. In addition, every mobile home installed after the effective date of this Chapter shall meet all of the following conditions: (1) The mobile home shall have an operable, approved smoke detector installed adjacent to sleeping rooms as prescribed by the City building code or other applicable federal standards. (2) The mobile home shall be equipped with two (2) operational exit doors. (3) The mobile home shall have all fuel-burning heating equipment as defined in the City mechanical code, including furnaces and water heaters, within the mobile home inspected by a qualified service technician, as determined by the Building Official, and found to be in safe operating condition. (4) All electrical wiring and distribution equipment within the mobile home shall be in safe working condition, and shall conform to nationally recognized standards which were applicable at the time of the construction of said mobile home. (5) All plumbing fixtures, drainage piping and water piping within the mobile home shall be in safe working condition. (6) The mobile home is determined by the Building Official to be generally in sound physical condition. (b) Mobile Home Installation Permit Required. No mobile home shall be installed on a mobile home lot after the effective date of this Chapter without first obtaining a mobile home installation permit for each such installation from the Building Official. A fee of twenty-five dollars ($25.) shall be paid to the City prior to issuance of each such permit. No permit shall be issued for installation of any mobile home not in compliance with the requirements of this Section. The application for such permit shall contain the following: (1) Name(s) of the mobile home owner. (2) Make, model and place of origin of the mobile home. (3) The proposed location of the mobile home, indicating mobile home park and lot identification. (c) Mobile Home Installation Standards. Every mobile home installed after the effective date of this Chapter shall comply with the following installation standards: (1) Site preparation and foundations. All foundation pad sites shall be cleared of vegetation, on undisturbed soil or approved fill and be graded such that supporting piers are plumb. The pier base shall be two (2) solid concrete blocks which provide a sixteen (16) inch by sixteen (16) inch by four (4) inch thick pad or a single concrete pad equivalent in size. Supporting piers shall be constructed of nominal eight (8) inch by eight (8) inch by sixteen (16) inch, celled concrete blocks placed directly on the pad and perpendicular to the main frame members of the mobile home and capped with a solid, nominal four (4) inch by eight (8) inch by sixteen (16) inch concrete block. Piers shall be spaced a maximum of eight (8) feet on center and be placed within five (5) feet of anchorage and be centered under frame members. End piers shall not be more than five (5) feet from the end of the mobile home. Piers greater than thirty-six (36) inches high shall be constructed with double-stacked blocks specified above. Piers greater than forty-eight (48) inches high shall be constructed of interlocking concrete blocks bonded together with approved mortar and grouted full or equivalent. Piers greater than seventy-two (72) inches high shall be designed by a qualified professional. Shims shall be used to level the mobile home and shall not exceed four (4) inches in thickness and shall be adequate to provide full bearing under the frame member. (2) Anchoring. Every such mobile home installed shall have an anchoring system installed which will prevent uplift, sliding, rotation and overturning. Such system shall be composed of approved cables, eyebolts, straps and other hardware sufficient to withstand a tensile load of four thousand seven hundred twenty-five (4,725) pounds at each anchor connection without failure, creep or withdrawal. All such hardware shall be corrosion-resistant coated steel or equivalent. For mobile homes fifty (50) feet in length or less, two (2) anchors along each side shall be provided. For mobile homes fifty (50) feet to seventy (70) feet in length, three (3) anchors shall be provided along each side. For mobile homes greater than seventy (70) feet in length, four (4) anchors shall be provided along each side. (3) Landings and porches. Every such mobile home installed shall be provided with a thirty-inch by thirty-inch landing or porch within eight (8) inches, measured vertically, of the entrance doorway threshold. Such landing or porch shall be served by stairs or ramp, guardrails and handrails constructed in accordance with the City building code. (4) Utility service connections. All utility service connections shall be installed and maintained in accordance with applicable City codes and shall be securely attached and supported as necessary. Water lines and connections shall be protected from freezing in an approved manner. Sewer connections shall be sealed in an approved manner at the point of connection to park services and shall be entirely under the mobile home. Gas valves shall be of an approved type. A pressure test as prescribed in the City mechanical code shall be performed on mobile home gas piping systems. (5) Skirting. Every such mobile home installed shall be provided with perimeter skirting between the ground and bottom of the mobile home floor within thirty (30) days after utility connections are made. Such skirting shall be of a durable, rigid, weather-resistant material approved for such use, such as exterior plywood, fiberglass or equivalent material. Skirting shall be securely attached to the mobile home to prevent unsupervised access to mobile home utility connections. Combustible storage shall be prohibited under mobile homes; provided, however, that tires mounted on wheels which are needed for transporting the mobile home shall be permitted to be stored under such mobile home.
(Ord. No. 159, 1987, 10-20-87; Ord. No. 014, 2026, § 1, 3-3-26)
Ask a question about Fort Collins law
Corpus searches the Fort Collins sections it holds and shows the ones that match, with their citations. Free, no sign-in.
