§ 26-309 — Existing industrial user discharge permit; application

Fort Collins Municipal Code (Supp. No. 156, Update 2: codified through Ordinance No. 122, 2026, enacted September 15, 2026) · Fort Collins Municipal Code § 26-309

Corpus is an independent public-information project, not the official City of Fort Collins website. Stable reference: corpuslaw.us/code/ce9f6395-d08c-4f9d-9985-5adba61fb511

Sec. 26-309. - Existing industrial user discharge permit; application.

(a) An existing industrial user may also be required to apply for an industrial discharge permit if it does not have one for its present use of the wastewater utility. An application shall be submitted within forty-five (45) days of notification by the utility of the need to do so or at the time of application for a building permit for expansion or remodeling of the premises or at the time of a material and significant alteration in the quantity or quality of the wastewater being discharged, or upon enactment of an applicable categorical standard, whichever occurs first. A new owner of premises with an existing connection to the wastewater utility desiring to introduce or continue an industrial activity shall also be required to contact the utility and if required, apply for an industrial discharge permit in accordance with this Section. (b) When required to apply for an industrial discharge permit, an existing industrial user shall provide the following information in addition to that required in § 26-308. (1) Wastewater quality. The constituents and characteristics of its wastewater as identified and determined by a reliable analytical laboratory, including but not limited to those mentioned in §§ 26-331 through 26-333 of this Article. Sampling and analysis shall be performed in accordance with procedures established by the EPA pursuant to Section 304(h) of the act and contained in 40 C.F.R., Part 136, as amended. (2) Flow measurements. Average daily and thirty-minute peak wastewater flow rates including daily, monthly and seasonal variations, if any. (3) Where known, the quantity and specific nature of any pollutants in the discharge which are limited by any pretreatment standards and a statement regarding whether or not the pretreatment standards or, if applicable, zero-discharge permit requirements, are being met on a consistent basis and if not, whether additional operation and maintenance and/or additional pretreatment or other process modification is required for the user to meet applicable pretreatment standards or zero-discharge permit requirements. (4) A written description and diagram of existing pretreatment equipment, if any, including but not limited to operational processes or controls, treatment processes, treatment tank dimensions and retention time, chemical supplies, operating personnel and certification, and a plumbing diagram of the treatment system. (5) If additional pretreatment and/or operation and maintenance will be required to meet the pretreatment standards or applicable industrial discharge permit requirements, including but not limited to zero-discharge permit requirements, a proposed compliance schedule by which the user will provide such additional pretreatment. (6) Any information deemed necessary by the Utilities Executive Director to evaluate the permit application.

(Code 1972, § 112-75(C); Ord. No. 166, 1986, § 1(112-128(C), (D)), 11-4-86; Ord. No. 130, 2002, § 33, 9-17-02; Ord. No. 062, 2007, § 4, 6-5-07; Ord. No. 020, 2010, § 9, 7-20-10; Ord. No. 080, 2011, § 1, 9-6-11)

Ask a question about Fort Collins law

Corpus searches the Fort Collins sections it holds and shows the ones that match, with their citations. Free, no sign-in.