§ 22-109 — Section P2603.5 amended; freezing
Municipal Code of the City of Greeley, Colorado (Codified through Ordinance No. 16, 2026, enacted April 21, 2026 (Supp. No. 6, Update 1)) · Greeley Municipal Code § 22-109
Corpus is an independent public-information project, not the official City of Greeley website. Stable reference: corpuslaw.us/code/37c1839c-4ace-4d0f-a3ee-30b207c79339
Sec. 22-109. - Section P2603.5 amended; freezing.
Sec. P2603.5 of the residential code is amended to read as follows: P2603.5 Freezing. Water, soil or waste pipe shall not be installed outside of a building, in exterior walls, in attics or crawl spaces, or in any other place subjected to freezing temperature unless adequate provision is made to protect it from freezing by insulation or heat or both. Water service pipe shall be installed not less than 12 inches (305 mm) deep and not less than 12 inches (305 mm) below the frost line.
(Code 1994, § 16.06.310; Ord. No. 47, 2016, §§ 1(exh. A), 2(exh. B), 12-20-2016)
Ask a question about Greeley law
Corpus searches the Greeley sections it holds and shows the ones that match, with their citations. Free, no sign-in.