Sec. 22-44. - Section 406.3.2.1 amended; dwelling unit separation.

Sec. 406.3.2.1 of the building code is amended to read as follows: The private garage shall be separated from the dwelling unit and its attic area by means of a minimum five-eighths inch (15.9 mm) Type X gypsum board or equivalent applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than five-eighths inch (15.9 mm) Type X gypsum board or equivalent. Where the separation is a floor-ceiling assembly, or the ceiling is providing separation, the structure supporting the separation shall also be protected by not less than five-eighths inch (15.9 mm) Type X gypsum board or equivalent. Door openings between a private garage and the dwelling unit shall be equipped with either solid wood doors or solid or honeycomb core steel doors not less than 1⅜ inches (34.9 mm) thick, or doors in compliance with section 716.5.3 with a fire protection rating of not less than 20 minutes. Doors shall be self-closing and self-latching.

(Code 1994, § 16.04.140; Ord. No. 47, 2016, §§ 1(exh. A), 2(exh. B), 12-20-2016; Ord. No. 34, 2019, app. A, § 16.04.140, 9-3-2019; Ord. No. 16, 2022, § 33(app. A, § 33), 4-19-2022)

Ask a question about Greeley law

Corpus searches the Greeley sections it holds and shows the ones that match, with their citations. Free, no sign-in.