Sec. 24-502. - Residential development standards.

a. Building types and lot standards. The development standards for residential districts shall be based on the different building types permitted in each district, as specified in table 24-5-1. The design standards in other sections of this article may further specify the design and location of each building type in a specific context. [image omitted; see the official code] Figure 24-5-1: Building Types. Building types in Table 24-5-1 are distinguished based on lot sizes, unit configuration, building footprints and massing, building placement, and lot open space. This diagram illustrates the key elements standards in Table 24-5-1 applied to a typical lot. [image omitted; see the official code] Figure 24-5-2: Range of Building Types. Each zoning district allows a range of building types that are compatible based on the building scale, frontage design, and intent of the specific zoning district. The R-H zoning district allows the greatest range of building types, each specifically defined by the standards of Table 24-5-1: Residential Building Type and Lot Standards. Table 24-5-1: Residential Building Type and Lot Standards Zoning Districts | Building/Lot Types | # of Primary Units | Development Standards H-A | R-E | R-L | R-M | R-H | R-MH | Lot Standards | Minimum Setbacks [5] | Building Height Area | Width [1] | Lot Open Space | Front [2] | Interior Side | Corner Side [1] | Rear ■ | Agriculture Acreage | 1 | 40 + ac. | 300'+ | n/a | 35' | 25' | 25' | 50' | 30' ■ | ■ | ■ | ■ | Detached house — Estate lot | 1 | 13K + s.f. | 100'+ | 30% | 25' | 5' | 15' | 20' | 30' ■ | ■ | ■ | Detached house — Standard lot | 1 | 6K + s.f. | 60'—99' | 30% | 25' | 5' | 15' | 20' | 30' ■ | ■ | ■ | Detached house — Medium lot | 1 | 4.5K + s.f. | 45'—59' | 25% | 25' | 5' | 10' | 20' | 30' ◇ | ■ | Detached house — Small lot | 1 | 3K + s.f. | 35'—44' | 20% | 10' | 5' | 10' | 20' | 30' ◇ | ◇ | ■ | Detached house — Small format | 1 | 1.5K + s.f. | 25'—34' | 15% | 10' | 3' | 8' | 10' | 40' ■ | ■ | Multi-unit house — Standard lot | 2—4 | 6.5K + s.f. 2K s.f. per unit | 60'—99' | 25% | 25' | 5' [3] | 10' | 20' | 30' ■ | ■ | Multi-unit house — Medium lot | 2—3 | 4.5K + s.f. 2K + per unit | 45'—59' | 20% | 25' | 5' [3] | 10' | 20' | 30' ■ | Multi-unit house — Small lot | 2 | 3K + s.f. | 35'—44' | 15% | 10' | 5' [3] | 10' | 20' | 30' ■ | ■ | Row house — Standard lot | 3—8 | 1.5K + s.f. per unit | 21'—30' per unit | 12% | 10' | 5' [3, 4] | 10' | 10' | 40' ■ | Row house — Small lot | 3—8 | 1K + s.f. per unit | 14'—20' per unit | 10% | 10' | 5' [3, 4] | 10' | 10' | 40' ◇ | ■ | Apartment — Small lot | 3—12 | 4.5K—10K s.f. | 40'—79' | 10% | 10' | 5' [4] | 10' | 10' | 40' ■ | Apartment — Medium lot | 13—24 | 10K—30K s.f. | 80'—150' | 15% | 10' | 5' [4] | 5' | 10' | 50' □ | Apartment — Large lot | 25+ | 30K s.f.—2 ac. | 150'+ | 20% | 25' | 10' [4] | 15' | 10' | 70' ■ | Apartment — Complex, medium | 29 du/ac. | 2 ac.—5 ac. | 150'+ | 25% | 25' | 10' [4] | 10' | 20' | 40' □ | Apartment — Complex, large | 45 du/ac. | 5 + ac. | 300'+ | 30% | 25' | 20' | 20' | 25' | 60' □ | □ | □ | □ | □ | □ | Civic | 30K + s.f. | 100'+ | 40% | 25' | 5' | 20' | 20' | 40' ■ | ■ | ■ | ■ | ■ | ■ | Accessory Buildings | See residential accessory buildings in section 24-502.c ■ | ■ | Accessory buildings | See section 24-403.b for ADUs ■ Allowed ◇ Limited to projects that meet the housing diversity requirements of section 24-502.d. □ Civic buildings and uses, and Apartments — Large Lot or Large Complexes shall only be located on collector or arterial streets in residential districts. Zoning Districts: H-A Holding-Agriculture; R-E Residential Estate; R-L Residential Low Density; R-M Residential Medium Density; R-H Residential High Density; R-MH Residential Micro-Housing [1] Corner lots shall add at least 5' to the required lot width. Otherwise, lot width ranges shall determine the applicable building type standards within a category. [2] Front setbacks shall be modified based on context and the frontage design standards in section 24-503.b. [3] Row houses and side-by-side multi-unit houses (i.e., duplex), may be platted for individual ownership of the unit and lot, with a 0' interior side setback as provided in section 24-502.b.1(a). [4] Row houses, small apartments, and medium apartments shall have a 10' side setback when abutting lots with a detached house; large apartments/apartment complexes shall have a 20' side setback when abutting lots with a detached house. [5] Buildings that require a certificate of occupancy shall be set back at least 250' from an oil/gas facility, and 50' from a well that has been plugged and abandoned. Buildings that do not require a certificate of occupancy shall be set back 150' from a tank battery or oil/gas well (unless plugged and abandoned). See section 24-1102. b. Dimension exceptions. The following are exceptions to setback and building dimensions standards established in table 24-5-1. 1. Lot and building configurations. (a) Row houses and side-by-side multi-unit houses (i.e., duplexes) may be configured as a single project, provided the lot and building cumulative meet any per lot standards; or as individual lots with a zero-feet interior side setback, provided the building includes a party wall meeting building code standards. Individual ownership of units on a commonly owned lot are subject to the platting requirements in section 24-202. (b) Side lot easements between abutting lots may be granted in association with a plat to have the effect of "zero lot line" patterns. Easements for exclusive use of the side yard may be granted to the abutting owner to meet the lot open space requirements and design standards in section 24-503 for the grantee, yet maintain the required setbacks from the platted lot line for each building in table 24-5-1 for the grantor. Easements shall be private agreements and account for all access and maintenance scenarios for the lots, open space, and buildings. (c) The front setbacks for each building may be modified according to the frontage types and frontage design standards in section 24-503.b. (d) Lots may be configured in a courtyard pattern as provided in section 24-505. [image omitted; see the official code] | Figure 24-5-3: Row House and Duplex Lot Standards. The building and lot standards for row houses or side-by-side multi-unit houses (duplexes) can be applied to allow the same building configuration to be owned as individual lots and units (platted 0' party wall), owned as individual units on a common lot (condominium), or owned as a single project (rental of units), subject to required platting procedures. (Section 24-502.b.1(a)) [image omitted; see the official code] Figure 24-5-4: Side Lot Easements. Side lot easements may be used to provide more contiguous areas to meet the lot open space requirements, and have the effect of a zero lot line configuration. (Section 24-502.b.1(b)) 2. Setback encroachments. The following encroachments into the required setback are permitted, except in no case shall this authorize structures that violate the provisions of any easement: (a) Primary entrance features may encroach beyond the required front building line, as specified in section 24-503.b. (b) Structural projections such as bay windows, balconies, canopies, chimneys, eaves, cornices, open fire escapes, egress wells, or other non-foundational overhangs or projections may extend up to four feet from the foundation and encroach into the setback, but no closer than three feet from any lot line. This exception shall be limited to no more than 20 percent of the total area of a building elevation. (c) Unenclosed decks or patios at or below the first floor elevation may extend into the rear or side setback but no closer than five feet to any lot line. Where a roof is provided, it shall only be single story and shall remain unenclosed with at least 65 percent open and unobstructed on three sides. (d) Ground-mounted mechanical equipment, meters, and utility boxes accessory to the building may be located in the side or rear setback provided that it extends no more than six feet from the principal building, no closer than three feet to the lot line, and is screened from public right-of-way by structures or landscape. These limitations do not apply to any utility structures otherwise authorized to be located in easements or rights-of-way, subject to the design standards of those specific authorizations. (e) Any other accessory use or structure within the setback, not specified in section 24-502.c, shall have a setback of at least one-third its height from the property line. 3. Height exceptions. The following are exceptions to the height limits in table 24-5-1: (a) Building elements integral to the design and construction of the building, such as parapet walls, false mansards, or other design elements essential to a quality appearance of the building may extend up to six feet above the roof deck of a flat roof. (b) Architectural features such as chimneys, ornamental towers or spires, and similar accessory features that are cumulatively less than 20 percent of the building footprint may extend up to 50 percent above the actual building height. (c) Functional and mechanical equipment such as elevator bulkheads, cooling towers, smoke stacks, roof vents or other equipment may be built up to their necessary height in accordance with building codes, provided they are screened according to the standards of this code. c. Accessory buildings — Residential. Accessory buildings shall be permitted in association with, and on the same lot as, a principal building or use, subject to the standards in table 24-5-2, and to the following additional limitations. Table 24-5-2: Residential Accessory Structures Type | Quantity | Size | Height | Setbacks Minor structure (small shed, and similar structures) | • 1/lot; • + 1/each 10k s.f.; • Maximum of 3 | • 120 s.f. max | • 12' max | • 0' side or rear; • 5' if on a concrete slab or similar foundation; and • Behind the rear building line of the principal structure Secondary building (detached accessory building) | • 1/lot • 2/lot, over 1 ac.; • 1/principal building (apartments) | • 50% of principal building footprint, up to 1,200 s.f. max. | • 25' max., but no higher than principal structure. | • 5' from side and rear; • 20' from street side; and • At least 12' behind the front building line of the principal structure Any building over 12' high or more than 250 square feet shall meet the design standards in section 24-502.c.2. Outbuilding (large storage building, barns, etc.) | • 1/lot over 1 ac. • + 1/each 3 ac. • Maximum of 4 | • 2,000 s.f. max. • 5,000 s.f. max. in H-A | • 25' max. • 60' max. in HA | • 10' from side and rear; • 30' from any street side; and • Behind the rear building line of the principal structure Applies to detached houses and civic/institutional uses only 1. Generally. (a) All accessory buildings shall be at least six feet from the principal building, or other distance specified by applicable building codes based on fire ratings of adjacent walls. (b) Accessory buildings shall be clearly incidental and subordinate to the principal building or use, in terms of scale, location, and orientation. (c) Minor accessory structures 120 square feet or less, and not on a foundation or slab do not have a required side or rear setback, but should be movable and are otherwise placed "at risk" by the owner with regard to any easements, fence, or screening requirements. 2. Secondary building standards. In any residential district, secondary buildings over 250 square feet shall or over 12 feet high shall meet the following massing and design standards to ensure compatibility with the principal structure: (a) The wall height shall be no more than nine feet above the finished floor, except that gables, dormers, or other subordinate walls may support a pitched roof. (b) The roof peak or other top of structure shall not exceed 22 feet above finished floor for pitched roofs with a 6:12 pitch or greater, and no more than 16 feet for shed roofs or pitched roofs below a 6:12 pitch. (c) The design shall be compatible with the principal building considering materials, architectural details and style, window and door details, and roof forms. (d) Secondary buildings with vehicle access directly from an alley or shared easement may be built on the lot line at the alley or shared easement. d. Housing diversity. Individual projects shall meet the following housing diversity guidelines based on the scale and context of the project. Diversity shall be based on the categories and building types indicated in table 24-5-3, and be applied according to table 24-5-4. The guidelines shall be met by one or a combination of the following: 1. Use a mix of housing types permitted in the zoning district, or propose more than one zoning district within the project. 2. The director may waive this requirement where there is an existing mix of housing within one-quarter mile of the project that provides a comparable mix of housing considering the size, price points, and types of housing. 3. The director may approve alternative compliance if the applicant submits evidence that achieving the mix unreasonable based on industry data and conditions beyond the applicant's marketing information. Table 24-5-3: Housing Categories and Building Types Category I: Detached Houses | Category II: Missing Middle Housing | Category III: Multifamily and Mixed Use • Detached house — Estate lot • Detached house -Standard lot • Detached house — Medium lot | • Detached house — Small lot • Detached house — Compact/small format • Multi-unit house — Standard lot • Multi-unit house — Medium lot • Row house — Small lot • Row house — Large lot • Apartment — Small | • Apartment — Medium • Apartment — Large • Apartment complex (medium/large) • Apartment mixed-use building Table 24-5-4: Housing Diversity Project Scale | Required Mix < 50 units | no requirement 50—150 units | • At least 2 building types • No more than 70% of one type 151—300 units | • At least 3 building types • No more than 50% of one type • At least 20% Category II 301+ units | • At least 4 building types • No more than 50% of one type • At least 30% from Category II e. Fences and walls. Fences and walls in residential districts shall be limited to the sizes and locations in table 24-5-5, and the following additional standards. Table 24-5-5: Residential Fences and Walls Location Front In the front setback or any location in front of front building line | • 3.5' high • 3.5'—6' if it is ornamental design that is at least 75% open (i.e., wrought iron). • Up to 8' for ornamental features at pedestrian entries. Side and rear In the side, street side, or rear yard and behind the front building line. | • 6' high • A fence or wall outside of required setbacks (i.e., in the buildable envelope), and behind front building line can exceed 6', but may be limited by building codes or other general development and design standards. Perimeter fences Any fence within 30' of a collector or arterial street right-of-way as part of perimeter landscape in section 24-803. | Any fence designed as part of a perimeter landscape area along collector or arterial streets, or otherwise located within 30' of a collector or arterial right-of-way and longer than 100', shall meet the following standards: • All fencing shall be softened with landscape materials on the street side of fences meeting the perimeter landscape standards of section 24-802. • Expanses of over 100' shall be broken up by either: ◦ Offsets of +/- 3' on ⅓ of length for every 150' span; or ◦ Ornamental designs on at least 50' of every 150' space that is at least 75, open (i.e., wrought iron); or ◦ Architectural pillars or posts (i.e., stone, or masonry) at least every 50'. • Alternatives may be approved by the director in association with the perimeter landscape plans in section 24-803, streetscapes in section 24-301, and neighborhood features and common areas (trails) in section 24-504. All locations | All fences or walls along rights-of-way or easements shall be set back at least: • 1' from any ROW or easement that prohibits structures; otherwise fences in easements shall be permitted only subject to specific easement language and limitations. • 2' from any sidewalk. • 3' from the edge of any alley or similar vehicle access surface. • Fences or walls may only be located in the right-of-way or public easement by a revocable right-of-way permit from the public works department. 1. General fence and wall design standards. (a) All fences or walls located along common lot lines shall be located so the fence is on the property line, or at least three feet from the property line. Any areas set back three feet or more, which could become enclosed by other similarly located fences, shall provide at least one gate for access and maintenance equipment. (b) The finished side shall face adjacent property or any public right-of-way, public space, or common areas. (c) Any fence or wall in the floodplain shall also require a floodplain development permit. (d) All fence or walls shall be located and designed to comply with sight distance requirements of section 24-301.d.2. Any fence or wall that could potentially create a sight obstruction for vehicles crossing pedestrian areas or entering the street may require greater transparency or additional location restrictions to allow for safe sight distances for the vehicle. (e) Temporary fences for construction may be up to six feet tall or as otherwise specified in construction permits. (f) All fences and walls may be subject to additional standards of the building code, approved drainage plans for the lot, or other design and development standards. In particular, the following require a building permit when allowed by this code: (1) Any fence or wall over six feet. (2) Any retaining walls over four feet. (3) Walls in the setbacks over six feet shall only be permitted by alternative compliance in section 24-208. 2. Materials. Fences and walls shall be consistent in character, materials and appearance with the architecture of the principal building on the same lot. Fences and walls shall be constructed out of any of the following materials: (a) Wood or vinyl simulating wood. Wood shall be either naturally rot resistant (such as cedar), or pressure treated for rot resistance; (b) Wrought iron or aluminum simulating wrought iron; (c) Stone, brick, concrete with stone or brick veneer, pre-cast concrete simulated stone or brick, or decorative concrete textured to simulate masonry; or (d) Chain link or vinyl clad chain link, in the side or rear yard only and limited to four feet high, or up to 12 feet for any security fence around sports facilities, courts, pools or similar facilities, provided it is 20 feet from any lot line and provided all portions over eight feet remain free of opaque screens. _____

(Ord. No. 35, 2021, § 4(app. A, § 4), 9-21-2021)

Ask a question about Greeley law

Corpus searches the Greeley sections it holds and shows the ones that match, with their citations. Free, no sign-in.