§ 24-503 — Residential design standards
Municipal Code of the City of Greeley, Colorado (Codified through Ordinance No. 16, 2026, enacted April 21, 2026 (Supp. No. 6, Update 1)) · Greeley Municipal Code § 24-503
Corpus is an independent public-information project, not the official City of Greeley website. Stable reference: corpuslaw.us/code/dc04d283-a89d-4f6f-8a6e-990b2ad6085f
Sec. 24-503. - Residential design standards.
a. Applicability. The design standards shall apply to the R-L, R-M, and R-H zoning districts, and to any residential building type permitted in nonresidential zoning districts. The standards shall specifically apply to the following circumstances: Table 24-5-6: Applicability Activity | Applicability of Standards Site or landscape work on less than 50% of the lot | Standards only apply to changes associated with the proposed work, and only to the extent that any nonconforming situations for the entire site are brought closer to compliance. Site or landscape work on 50% of more of the lot | All site and landscape for the entire lot shall be brought into compliance with the standards. Rehabilitation, remodeling or additions to buildings that add more than 200 square feet to the building footprint or mass, but less than 50% | Standards only apply to changes associated with the propose work, and only to the extent that any nonconforming situations for the entire site are brought closer to compliance. However, staff may require full compliance for the building and lot for any rehabilitation, remodel or addition that is greater than 75% of the assessed value. New primary structure; or rehabilitation, remodeling or additions to the building that add more than 50% to the building footprint or mass | All standards for the entire building and lot shall be met. Ordinary maintenance | The standards shall not apply to ordinary maintenance of existing buildings, except that maintenance to any building may not occur in a manner that brings the building or site to a greater degree of nonconformance with these standards. b. Frontage design. The design of lot frontages establishes the relationship of buildings and lots to the streetscape, including building placement, lot access, garage extent and location, and entry features. Frontage types designed according to the standards and design objectives of this subsection may be used to modify the front setback established in table 24-5-1. 1. Design objectives. Frontage types shall be applied to meet the following design objectives: (a) Enhance the image of neighborhoods by coordinating streetscape investment with private lot and building investment. (b) Design frontages to the particular context of the neighborhood, block and street. (c) Coordinate development across several lots, considering the cumulative impacts on streetscapes from the frontage design of each lot. (d) Orient all buildings and lot frontages to the streetscape, while still promoting effective transitions from public spaces to private spaces on the lot. (e) Limit the impact on the neighborhood streetscape from frontages designed for car access, particularly on narrower lots or walkable streets and neighborhoods. (f) Provide outdoor livable spaces that activate the streetscape. (g) Use front entry features to reinforce neighborhood character, promote unique design with subtle variations to building patterns, and create consistent, human-scale connections to the streetscape. 2. Frontage design standards. Frontage types shall be designed according to the standards in table 24-5-7. Subsections following the table provide specific design strategies and techniques to be used in meeting these standards and design objectives. Where multiple frontage types are permitted, the frontages should be similar for all lots on the same block face or gradually transition to different building placement and frontage types on adjacent lots. In general, the front building line of adjacent buildings shall not differ by more than five feet. [image omitted; see the official code] | [image omitted; see the official code] | [image omitted; see the official code] Figure 24-5-5: Frontage Design Standards. This diagram illustrates the key elements of frontage design in Table 24-5-7: (A) front building line; (B) front entry features, (C) driveway widths; (D) garage extent and location, and (E) landscape areas. These elements determine the relationship between the building, the lot, and the streetscape, and affect the character of the area when applied across multiple lots on a block. Table 24-5-7: Residential Frontage Types and Design Standards Frontage Element | Terrace Frontage | Neighborhood Frontage | Suburban Frontage [image omitted; see the official code] | [image omitted; see the official code] | [image omitted; see the official code] [image omitted; see the official code] | [image omitted; see the official code] | [image omitted; see the official code] Application | R-L | □ Required frontage type for R-L in the Legacy Urban & Downtown Neighborhood areas | ■ R-M | □ | ■ R-H | □ | ■ Front building line | 10'—25' | 25'—60' | 25'+ Front entry feature | Required, see section 24-503.b.5 | Required, see section 24-503.b.5 | Required, see section 24-503.b.5 Driveway width | 15% of lot width, up to 20' maximum | 20% of lot width, up to 20' maximum | 50% of lot width, up to 27' maximum Garage limitations | • 20% of façade — must be at or behind FBL; • Up to 35% if stepped back 12'+ from FBL | • 35% of façade — must be at or behind FBL; • Up to 45% if stepped back 12'+ from FBL | • 65% of façade — no more than 12' in front of FBL Landscape [1] | • 60% minimum landscape; and • 40% maximum hardscape. | • 70% minimum landscape; and • 30% maximum hardscape. | • 50% minimum landscape; and • 50% maximum hardscape ■ Required, default standard. □ Optional, alternative standard to be applied based on context. [1] Landscape refers to allocation of space between front lot line and front building line. See section 24-802 Landscape design for planting requirements, standards, and specifications. 3. Driveway limits. Driveway limits maintain active spaces along the frontage, preserve areas of streetscape landscape, and reduce curb cut width protecting sidewalks and curbside parking. The following standards apply to the driveway limits in table 24-5-7: (a) Driveway width limits apply to the first 50 feet of the lot depth, or up to the front building line, whichever is less. (b) Any garage meeting the design standards in this section may have a driveway expanded to the width of the entry, provided: (1) The expansion extends no further than 20 feet from the garage entry; (2) The expansion cannot be closer than ten feet to the front property line; and (3) The width of the driveway within the right-of-way and first ten feet shall be reduced to no wider than 20 feet wide. (c) In cases where driveway width and garage standards prohibit front-loaded garages and driveways on a particular lot, a range of options with different access patterns and garage locations may be used. (d) All parking shall be outside of the frontage area, except detached houses or multi-unit houses may have one of the required parking spaces per unit in the driveway, provided it is at least seven feet by 18 feet, entirely outside of the right-of-way, and does not interfere with any pedestrian area. [image omitted; see the official code] | [image omitted; see the official code] Figure 24-5-6: Application of Driveway Limits. Driveway limits shall apply to the first 50' or up to the front building line, whichever is less, except any front-loaded garage meeting these standards may have a driveway expanded to the width of the entry 20 feet in front of the entry. (Section 24-503.b.3(a) and (b).) [image omitted; see the official code] Figure 24-5-7: Driveway and Garage Options. Frontage type standards are based on lot widths to recognize both the proportionate and cumulative effect that frontage design elements have on the streetscape, and narrower or compact lots may be more limited. In these situations, options that reduce the car-orientation yet accommodate the convenience of access of vehicles should be used. Options include narrower entries, side entries, shared drives, common lanes, or internal block alleys. (Section 24-503.b.3(c).) 4. Garage design. Garage design reduces the extent; massing, and proximity and of front-loaded garages relative to the streetscape, and promote more human-scale building elements and active living areas along the frontage. The following standards apply to the garage limits in table 24-5-7: (a) Garage limits apply to front-loaded garages. Alternatives such as detached garages, side or rear-loaded garages, or attached garages that are accessed from the front but located on the rear of buildings are not subject to the limits. (b) Garage limits shall be measured by the exterior walls of the floor plan or other clearly distinguished massing element on the front façade; (c) Any front-loaded garage that is more than 35 percent of the elevation or that projects in front of the main mass of the house shall include at least two of the following features to reduce the scale and prominence of the garage: (1) A front entry feature associated with the non-garage mass of the building that projects in front of or is no more than four feet behind the garage entry, and is at least ten feet wide. (2) The wall plane with a garage door is limited to no more than 200 square feet, and distinguished from other wall planes by the following: i. At least one bay stepped back at least two feet; and/or ii. Ornamental features such as canopies, eyebrows, or cantilevers distinguish the wall plane of any upper level gables or living space. (3) Garage doors and any other related wall planes have at least 15 percent windows, and other ornamental trim or accents are included on the doors and pillars related to the garage entry. [image omitted; see the official code] Figure 24-5-8: Front Loaded Garage Design. Where front-loaded garages project in front of the main mass or occupy a larger percentage of the elevation, design strategies can be used to reduce the scale and coordinate the garage entries with other livable spaces of the building. (Section 24-503.b.4.) 5. Front entry features. The entry feature standards and design techniques in table 24-5-8 shall be used where entry features are required by frontage types in table 24-5-7, and are otherwise recommended to achieve the design objectives of this section and to meet the standards of table 24-5-9. Table 24-5-8: Front Entry Features Design Element | Width | Depth | Details and Ornamentation Porch | 12' minimum | 8'—12' | • Decorative railing or wall 2.5' to 4' high along at least 50% of the perimeter. • If not roofed, a canopy, pediment, transom windows, enlarged trim and molding or other similar accents accompany the front entrance. Suburban frontage may reduce porch to 48 s.f.; at least 4' in all directions. Stoop | 6'—12' | 6'—8' | • Decorative railing or walls along steps and side of stoop. • Ornamental features accent the front entrance such as canopy, pediment, transom windows, enlarged trim and molding, or other similar accents that emphasize the door over other façade features. • May be associated with a single-story enclosed front entry portico, projecting from the building. Entry court | 12'+, but never more than 50% of façade | 10'—24' | • Recessed entry within the building footprint. • Decorative wall or railing, no higher than between 2.5' and 6' high along at least 50% of the opening. • Ornamental pillars, posts or landscape accent the pedestrian entrance and create a gateway into the entry court. General design | • All entry features shall have a sidewalk or path at least four feet wide directly connecting the entry feature to the public sidewalk or street. For suburban frontage, this can connect via the driveway. • All entry features shall be integrated into the overall building design including compatible materials, roof forms, and architectural style and details. • Entry features shall be single-story, so that any roof structure and any ornamentation occur between 8' and 14' above the floor-level of the entry feature. • Entry features meeting these standards may encroach up to 10 feet in front of the front building line, but never closer than 5 feet to a public or common property line, provided they are unenclosed with at least 65% open and unobstructed on all sides that project into the setback. • Any building with more than 150 feet of front façade, or any side greater than 200 feet and permitted within 20 feet of the street, shall have 1 entry feature for every 100 linear feet of building frontage on the street. [image omitted; see the official code] | [image omitted; see the official code] | [image omitted; see the official code] Porch | Stoop | Entry Court Figure 24-5-9: Front Entry Features — Types. The porch, stoop and entry court are three distinct types of entry features that create active, social spaces and human-scale details on the residential frontages. Spaces with a minimum width (A) and depth (B) specified in table 24-5-8 provide usable social spaces, activate the streetscape and frontage, and contribute to the massing and modulation required by the building design standards. [image omitted; see the official code] Figure 24-5-10: Primary Entry Feature — Encroachments. Front entry features meeting the standards of this section create social spaces that help activate streetscapes, and create a variety of human-scale details along blocks. These features may encroach into the front setback to improve the frontages along blocks. (Section 24-503.b.5/Table 24-5-8.) [image omitted; see the official code] Figure 24-5-11: Primary Entry Feature — Large Buildings. Front entry features should be more frequently located on larger buildings with wall planes in close proximity to the street. This breaks up the building massing and activates the streetscape. (Section 24-503.b.5/Table 24-5-8.) 6. Alternative compliance. Alternative compliance to the frontage design standards established in this section may be authorized according to the process and criteria in section 24-208, Alternative compliance, and any of the following additional applicable criteria: (a) The context presents clear pattern of existing buildings and lots on the same block and opposite block face with a different arrangement in terms of the front building line, driveway access patterns, and extent and placement of garages. (b) An alternative design allows the building, garage, and access to be sited in a way that preserves topography or other natural features on the site, and does so in a way that equally or better meets the design objectives. (c) The alternative preserves the streetscape landscape area and the curb areas available for on-street parking to the greatest extent practical. (d) For detached houses or multi-unit houses alternatives to the driveway widths and setbacks may be approved for a required, accessory or guest parking space provided: (1) No other reasonable alternative exists; (2) It is limited to no more than 140 square feet of additional paved or all whether surfaces; (3) The expanded paving is at least ten feet from the front lot line if 45 degrees to perpendicular to the front, or at least 25 feet if 45 degrees to parallel to the front; (4) All drainage and potential impacts on adjacent property are addressed; and (5) The director may require other design or landscape mitigation to ensure the parking and access is as discreet as possible. (e) In all cases the deviation is the minimum necessary to address the circumstance and does not negatively impact other design standards applicable to the building or site. [image omitted; see the official code] | [image omitted; see the official code] Figure 24-5-12: Accessory Parking Pad. To meet parking requirements, accessory parking pads may be approved by alternative compliance provided they minimize impacts on the streetscape and adjacent property. (Section 24-503.b.5(c).) c. Building design. Building design refines the scale and form of buildings beyond basic height, setback and lot coverage standards. 1. Design objectives. The following design objectives shall be used in applying the building design standards in this section: (a) Relate buildings to public realm and streetscape in a consistent manner and create a compatible massing along the block. (b) Arrange buildings in a way that creates meaningful outdoor spaces on the site, with building designs that define and activate these spaces. (c) Use combinations of height, width, depth, and roof forms break down the building volume into smaller-scale masses. (d) Blend a variety of building sizes and types and create compatible transitions between adjacent buildings of different scale by mimicking similar massing and proportions of adjacent development. (e) Use materials and human-scale architectural features to create depth, texture, variation and visual interest to walls, particularly on larger façades, along streetscapes, and near active open spaces or adjacent lots. (f) Encourage unique architectural expression, and promote the use of key details and design characteristics inherent in the chosen style for the building. (g) Promote enduring investments with the application of durable, quality materials. 2. Building design standards. Table 24-5-9 provides standards for massing and façade design. Subsections following the table provide specific design strategies and techniques to be used in meeting these standards and design objectives. Table 24-5-9: Building Design Standards Design Detail | Building Type | Detached House (all), and Multi-Unit House | Row House, Apartment (all) Wall Plane Limits Maximum wall plane without a massing variation of 4'+ on at least 25% of elevation | [image omitted; see the official code] | 800 s.f. or 50 linear feet | 1,200 s.f. or 70 linear feet Blank Wall Limits Maximum wall plane without modulation on at least 20% of the wall plane | [image omitted; see the official code] | 500 s.f. or 30 linear feet | 800 square feet or 45 linear feet Roof Plane Limits Maximum roof plane without offset of at least 2', complex planes, dormers or gables | [image omitted; see the official code] | 600 s.f. or 50 linear feet | 1,000 s.f. or 70 linear feet Does not apply to flat roofs, provided there is a parapet, cornice or other defined edge at the roofline Transparency Minimum window and door openings per elevation (includes decorative trim, molding and casing) | [image omitted; see the official code] | Front — 20%; 15% 1-story Side n/a, except 8% if side yard is > 2× required setback Street-side 10% Rear 8% | Front — 20% Side 8% Street-side 10% Rear 8% Exterior walls of any allowed garage may be excluded from this requirement, provided other architectural details and materials are used to meet any applicable modulation requirements Materials | [image omitted; see the official code] | Primary Materials — 80%—90% (limit 2 materials, no more than 80% of any one material) Secondary/Accent Materials — 10%—20% (limit 2 materials) Primary Materials: Lap siding (9" maximum board); vertical siding; alternative exposure pattern siding; brick, stone, stucco, synthetic/veneer brick or stone; and standing seam metal (roofs only) Secondary/Accent Materials: All primary materials, plus architectural metals, integrally tinted and textured masonry block; and wood or prefabricated synthetic trim or architectural details. 3. Wall plane limits. Massing techniques use changes in the building footprint, height, or significant shifts in wall and roof planes to break down the volume of larger buildings. Wall planes that exceed the wall plane limits in table 24-5-5 shall have at least 25 percent of the elevation differentiated by one or more of the following massing techniques: (a) Break the building into distinct masses (primary mass, secondary mass, and wings), where portions of the building are offset from the main mass by at least eight feet, or are otherwise be noticeably smaller and subordinate to the main mass. (b) Step back portions of the building or upper stories by at least four feet in association with meaningful outside space, such as a balcony, deck, patio or entry court. (c) Use cantilevers of upper stories that provide at least a two feet overhang of other portions of the wall plane. (d) Provide single-story entry feature that project at least six feet from the wall plane. (e) Articulate rooflines by stepping the roof, using gables and dormers, dropping eaves, and using prominent overhangs to create offsets and projections of at least two feet. (f) Where larger buildings are next to smaller buildings, or are along a block with smaller buildings, step the height of the building or offset secondary masses to create compatible massing with adjacent structures. [image omitted; see the official code] Figure 24-5-13: Wall Plane Limits. Wall planes over the size specified in table 24-5-9 shall be broken up with a range of techniques so that at least 25% of the elevation is differentiated with distinct wall planes. (Section 24-503.c.3.) 4. Blank wall limits. Modulation uses materials, ornamental details, and subtle variations in the wall plane to break up blank wall planes. Wall planes that exceed the blank wall limits in table 24-5-9 shall use one or more of the following techniques so that at least 20 percent of the façade is distinguished with modulated elements: (a) Create projections in the wall planes with bay windows, balconies, awnings, or canopies that project at least two feet from the wall plane. (b) Create voids in the wall plane with step-backs of upper stories or balconies that recess at least four feet beyond the wall plane. (c) Differentiate stories, roofs, or other masses with prominent trim materials and/or incorporate material changes on different modules of the building. Significant trim or ornamentation used to break up blank walls or wall planes shall project between two inches and two feet from the wall and be at least eight inches wide. (d) Use color changes and accent materials to emphasize distinct components of the façade. Material and color changes should wrap corners and occur at the inside corner of a massing element, or occur in association with a significant trim or ornamentation to give a finished and unified appearance to the element. (e) Break up remaining large expanses of blank walls with façade composition that considers the location and grouping of windows, doors, or architectural details. [image omitted; see the official code] Figure 24-5-14: Blank Wall Limits. Wall planes over the size specified in table 24-5-9 shall have ornamental details or subtle variations in the wall plane on at least 20 percent of any wall plane to eliminate large expanses of blank walls. (Section 24-503.c.4.) 5. Transparency. Windows and doors provide transparency, detail, and visual rhythm on the façade, and they break up blank walls with the location, pattern, and proportions of these openings. The following techniques should be used to achieve the design objectives of this subsection and to meet the windows and doors requirements of table 24-5-9: (a) Provide transparency with the location, pattern, and proportions of windows and doors, and create relationships to surrounding spaces and buildings. (b) Incorporate distinct and visually significant windows and doors (size, orientation, and ornamentation) to emphasize key locations on the façade or to relate to important outside open spaces. (c) Locate windows doors to create a coordinated façade composition considering the entire façade as a whole, and to break up large expenses into different components with the grouping of windows and doors. (d) Emphasize a hierarchy of doors with different levels of ornamentation and details, particularly to make multi-unit houses compatible with adjacent detached houses and appear as single houses. (e) Locate and design windows strategically in relation to privacy concerns in adjacent spaces and buildings, but maintain consistent exterior patterns; recall that high-bank windows, transom windows, opaque windows, and window treatments that are adaptable and user-controlled are a better strategy than simply no windows at all. (f) Use windows and doors with projecting trim and ornamentation to create depth, texture, and shadows on the façade; to emphasize openings; or to gang groups of openings. Openings that have projecting trim and casements (at least one inch off the façade and four inches wide); or otherwise group widows with significant details that clearly differentiate these elements from the main façade may count these features for up to 25 percent of the window and door requirement. (g) The window requirement may be waived on sides of buildings that are closer than three feet to the property line, if necessary to meet applicable building code requirements. [image omitted; see the official code] Figure 24-5-15: Transparency. The minimum transparency specified in table 24-5-9 shall create connections to outside spaces and break up blank walls. Enhancements that emphasize the windows and the location, arrangement, or grouping of windows may count to this requirement. (Section 24-503.c.5.) 6. Materials. Building materials with texture and patterns create visual interest and signify quality construction and detailing. The following techniques should be used to achieve the design objectives of this section and the materials standards of table 24-5-9: (a) Use natural materials such as painted or natural finish wood siding (horizontal lap, tongue-and-groove, board and batten, or vertical), brick, stone, stucco, ceramic, or terra cotta tile. Synthetic alternatives to these natural materials may be used if manufacturer specifications and/or precedents for application demonstrate that it will perform equally or better than the principal materials in terms of maintenance, design, and aesthetic goals. (b) Siding shall be continued to within 18 inches of finished grade on any side, unless the foundation is stone, stone veneer, or other ornamental finish is applied. (c) Brick, stone, or other ornamental accent materials shall wrap the corner for at least two feet on any façade, or otherwise terminate at interior corners to give a finished appearance to the architectural element. (d) Coordinate changes in color and materials in association other changes in massing and modulation of the building. (e) Use changes in color or materials to differentiate the ground floor from upper floors and the main body of the building from the top or roof structure, particularly on buildings three stories or more. (e) In multi-building projects, use subtle variations in building materials and colors on different buildings, within a consistent palette of materials and colors. 7. Variations of buildings. All projects involving three or more buildings shall provide variations in the elevation from the two buildings on each adjacent side, and the three nearest buildings on the opposite side of a facing block, with at least two of the following: (a) Variations in the front entry features as indicated in section 24-503.b.5. Variations should include combinations of at least two of the following changes: (1) Different types of entry features: such as, porch, stoop, or entry court; (2) Different roof styles associated with the entry feature: such as gable, hip, shed, flat, arched, or no roof; (3) Different locations and extent of the entry feature: such as centered, shifted, wrapped; projecting, or embedded; and half or full; and/or (4) Different ornamentation or architectural styles that lead to distinct qualities within a similar scale or pattern; (b) Variations in the façade composition, including massing, modulation, window types and placement, materials and material changes, and details and ornamentation, to the extent that the buildings have a distinct appearance; (c) Variations of the roof forms considering the type of roof, orientation of gables, or use of dormers; or (d) Variations of the model or building type with distinctively different floor plans that lead to different massing. Mirror images of the same model and floor plan shall not be used to meet the variation requirement. (e) In the case of multi-unit buildings: (1) For duplexes/multi-unit houses that are intended to mimic the scale and form of detached houses, a hierarchy of doors and entrances shall be used to create the appearance of a single building, and the variation shall apply between buildings. (2) For row houses and similar buildings that are clearly designed for multiple units, subtle variations in the materials and entry features shall apply to emphasize different units, and the variation shall apply between units in the building. [image omitted; see the official code] Figure 24-5-16: Front Entry Features — Variety. Using a wide variety of entre feature types, styles and designs is a way to create subtle distinctions between the same or similar building types, and can add common human-scale patterns among different types or scales of buildings. (Section 24-503.b.5 and b.7) 8. Alternative compliance. Alternative compliance to the building design standards established in this section may be authorized according to the process and criteria in section 24-208, and any of the following additional applicable criteria: (a) The requirement is not consistent with the particular architectural style selected for the building based on reputable resources documenting the style. (b) The requirement would make the building less compatible with designs or characteristics of other buildings or sites adjacent to the project or that are prevalent throughout the area. (c) Deviations from material standards and any simulated products demonstrate a proven performance in terms of maintenance and quality appearance. (d) In any case, the deviation is the minimum necessary to address the circumstance and does not negatively impact other design standards applicable to the building or site. d. Lot open space design. Lot open space helps scale buildings properly to the lot and block, create transitions from public streetscapes to private lots, and ensure that residents have usable open space and outside social areas. These spaces also complement the neighborhood features, common areas, and public parks throughout the neighborhood. Open space designed according to the standards and design objectives of this subsection shall be used to meet the lot open space standard established in table 24-5-1. 1. Design objective. The following design objectives shall be used to apply the lot open space standards in this section: (a) Promote the arrangement of neighborhoods, blocks and lots in a way that responds to the existing natural features and ensures access to a variety of open spaces. (b) Design all unbuilt areas to serve as valuable neighborhood features, considering the aesthetic, ecological, recreation, or community serving potential of these spaces. (c) Ensure that all lots and buildings have access and proximity to useable open space, whether public, common or private on-lot spaces. 2. On-lot open space design. On-lot and building open space required for each building type in table 24-5-1 shall create a common or private amenity for the site and building. Buildings and open spaces on a lot shall be arranged to create usable outdoor spaces that meet one or more of the following types: (a) Private frontage areas designed according to section 24-503.b, excluding any driveways, parking areas or other automobile space; (b) A front entry feature designed according to section 24-503.b.5, provided it is at least 80 square feet, and at least eight feet in all directions—this space is limited to no more than 25 percent of the requirement for the lot and building. (c) Courtyards, meeting the standards of section 24-505; (d) Rear or side yards provided they are part of an open area at least 300 square feet and at least 15 feet in all directions. (e) Uncovered decks or patios, provided they are part of an open area at least 120 square feet and at least ten feet in all directions—this space is limited to no more than 50 percent of the requirement for the lot and building; (f) Apartment or mixed use buildings may also count the following spaces: (1) Common rooftop decks provided they are at least 200 square feet, and at least 12 feet in all directions—this space is limited to no more than 25 percent of the requirement for the lot and building; or (2) Private balconies or patios, provided they are at least six feet by ten feet — this space is limited to no more than 25 percent of the requirement for the lot and building. 3. Alternative compliance. Alternative compliance to the open space design standards established in this section may be authorized according to the process and criteria in section 24-208, and any of the following additional applicable criteria: (a) The lot and building has access to at least two different active open space within 1,320 feet, and meeting the design and service area standards section 24-504. (b) All buildings and lots shall include at least one of the required lot or open space types. e. Exterior lighting. All exterior lighting in residential zoning districts shall meet the standards of section 24-603.f.
(Ord. No. 35, 2021, § 4(app. A, § 4), 9-21-2021)
Ask a question about Greeley law
Corpus searches the Greeley sections it holds and shows the ones that match, with their citations. Free, no sign-in.
