Sec. 14.04.500. - Plumbing fixture standards established.
A. Water closets operated by flush tanks. The water consumption of water closets operated by flush tanks shall not exceed an average of 1.6 gallons per flush cycle over a range of test pressures from 20 to 80 psig. The fixture shall perform in accordance with the flushing test requirements cited in the ANSI (American National Standards Institute) Vitreous China Plumbing Fixtures Standard. B. Water closets and urinals operated by flushometers. 1. Water closet water consumption shall not exceed an average of 1.6 gallons per flush cycle over a range of test pressures from 20 to 80 psig. The flushometer shall be adjusted according to manufacturer's specifications. The fixture shall perform in accordance with the flushing test requirements cited in the ANSI Vitreous China Plumbing Fixtures Standard. 2. Urinal water consumption shall not exceed an average of one gallon per flush cycle over a range of test pressures from 20 to 80 psig. The flushometer shall be adjusted according to manufacturer's specifications. The fixture shall perform in accordance with the flushing test requirements cited in the ANSI Vitreous China Plumbing Fixtures Standard. C. Showerheads. Showerhead discharge rates shall not exceed 2.5 gallons of water per minute over a range of test pressures from 20 to 80 psig. The fixture shall perform in accordance with the test requirements cited in the ANSI plumbing fixture fittings standard. D. Sink faucets. 1. Nonresidential lavatory faucets shall be either self-closing or metering faucets, as described below: a. Self-closing faucets shall not exceed an average discharge rate of 0.5 GPM between the pressures of 20 and 80 psig when tested in accordance with the discharge test procedure cited in ANSI plumbing fixture fittings standard. b. Metering faucets shall be field adjustable and set so that the discharge quantity shall not exceed 0.5 gallons of water per cycle. 2. Residential interior faucets discharge rates shall not exceed 2.5 gallons per minute over a range of test pressures from 20 to 80 psig. The faucets shall perform according to the test requirements cited in the ANSI plumbing fixture fittings standard. E. Blowout toilets and urinals. Replacement of blowout toilet and urinal fixtures with like type fixtures may be granted by the director of public works and natural resources upon written request where adequate justification of special need is provided.
(Code 1993, § 14.04.500; Code 2009, § 14.04.500; Ord. No. O-84-77, § 1; Ord. No. O-93-33, § 32; Ord. No. O-96-43, § 10; Ord. No. O-2000-67, § 3; Ord. No. O-2015-09, § 26, 1-27-2015)
Ask a question about Longmont law
Corpus searches the Longmont sections it holds and shows the ones that match, with their citations. Free, no sign-in.