Sec. 16.06.330. - Section M1701.1 amended; scope.

Section M1701.1 of the International Residential Code is amended by the addition of the following section M1701.1.1: M1701.1.1. All air from indoors. Combustion and dilution air shall be permitted to be obtained entirely from the indoors in buildings that are not of unusually tight construction, in accordance with provisions of the 2024 International Fuel Gas Code section 304.5 as amended. Buildings classified as Group R occupancies, constructed with permits issued on or after March 1, 1989, are classified as buildings of unusually tight construction. For buildings of unusually tight construction, combustion air shall be obtained from the outdoors in accordance with provisions of the 2024 International Fuel Gas Code section 304.6 as amended. Exception: Buildings classified as Group R or single-family occupancies shall be provided with a minimum 28-square inch opening to outdoor air at the time of replacement or addition of fuel utilization equipment for which a permit is required.

(Ord. No. O-2026-24, § 1, 6-9-2026)