13.10.611 - Sample collection.
A. Samples collected to satisfy reporting requirements must be based on data obtained through appropriate sampling and analysis performed during the period covered by the report, based on data that is representative of conditions occurring during the reporting period. B. Except as indicated in Subsections C and D below, an industrial user must collect wastewater samples using 24-hour flow-proportional composite collection sampling techniques. In the event flow proportional composite collection sampling is not feasible, the director may authorize the use of time proportional sampling or a minimum of four grab samples where the industrial user demonstrates that this will provide a representative sample of the discharge. Using protocols (including appropriate preservation) specified at 40 C.F.R. Part 136 and appropriate EPA guidance, multiple grab samples collected during a 24-hour period may be composited prior to the analysis as follows: for cyanide, total phenols, and sulfides, the samples may be composited in the laboratory or in the field; for volatile organics and oil and grease, the samples may be composited in the laboratory. Composite samples for other parameters unaffected by the compositing procedures as documented in approved EPA methodologies may be authorized by the director, as appropriate. In addition, grab samples may be required to show compliance with instantaneous limits. C. Grab samples must be used for oil and grease, temperature, pH, cyanide, total phenols, and volatile organic compounds. Temperature and pH must be an instantaneous measurement. D. For sampling required in support of baseline monitoring and 90-day compliance reports required in Sections 13.10.601 and 13.10.603, a minimum of four grab samples must be used for pH, cyanide, total phenols, oil and grease, sulfide, and volatile organic compounds for facilities for which historical sampling data do not exist; for facilities for which historical sampling data are available, the director may authorize a lower minimum. For the reports required by Section 13.10.604, the industrial user is required to collect the number of grab samples necessary to assess and assure compliance with applicable pretreatment standards and requirements.
Ask a question about Loveland law
Corpus searches the Loveland sections it holds and shows the ones that match, with their citations. Free, no sign-in.