Sec. 10-260. - Light.

(a) Habitable spaces. Every habitable space shall have at least one window of approved size facing directly to the outdoors or to a court. The minimum total glazed area for every habitable space shall be eight percent of the floor area of such room. Wherever walls or other portions of a structure face a window of any room and such obstructions are located less than three feet (914 mm) from the window and extend to a level above that of the ceiling of the room, such window shall not be deemed to face directly to the outdoors nor to a court and shall not be included as contributing to the required minimum total window area for the room. (1) Exception: Where natural light for rooms or spaces without exterior glazing areas is provided through an adjoining room, the unobstructed opening to the adjoining room shall be at least eight percent of the floor area of the interior room or space, but a minimum of 25 square feet (2.33 m2). The exterior glazing area shall be based on the total floor area being served. (b) Common halls and stairways. In non-residential occupancies, means of egress, including exterior means of egress, stairways shall be illuminated at all times the building space served by the means of egress is occupied with a minimum of one foot-candle (11 lux) at floors, landings and treads. (c) Outer spaces. All other spaces shall be provided with natural or artificial light sufficient to permit the maintenance of sanitary conditions, and the safe occupancy of the space and utilization of the appliances, equipment and fixtures. (d) Off-street lighting. Off-street parking for non-residential uses that offers service after dark shall be lighted beginning one-half hour after sunset and continuing throughout the hours of use. If only a portion of the parking area is offered for use after dark, only that part shall be lighted. The lighting of the off-street parking area shall meet the following minimum requirements: (1) The intensity of light on the parking surface shall be a. An average of at least one foot-candle, initial measurement; and b. A minimum at any point of at least four-tenths foot-candle initial measurement. Requirements for maintenance of parking lot lighting shall include replacement of bulbs and light fixtures, regular cleaning, and replacement of light poles as needed. (2) The light source shall be indirect, diffused, or shielded type fixtures, installed to reduce glare and the consequent interference with boundary streets and adjacent property. (3) Fixtures shall be attached to buildings or mounted on poles in such a manner and at such a height that light is not directed at a residential use. (4) Maximum height of lights shall not exceed 35 feet. (e) Exterior lighting. Refer to City Code Chapter 18, Article VI, Division 5 for requirements for outdoor lighting.

(Ord. No. 3403, § 1, 9-13-16; Ord. No. 3745, § 11, 8-26-25)

Ask a question about Thornton law

Corpus searches the Thornton sections it holds and shows the ones that match, with their citations. Free, no sign-in.