Sec. 10-262. - Occupancy limitations.

(a) Privacy. Hotel units, motel units, and rooming units shall be arranged to provide privacy and be separate from other adjoining spaces. (b) Minimum room widths. A habitable room, other than a kitchen, shall be a minimum of seven feet (2134 mm) in any plan dimension. Kitchens shall have a minimum clear passageway of three feet (914 mm) between counter-fronts and appliances or counter-fronts and walls. (c) Minimum ceiling heights. Habitable spaces, hallways, corridors, laundry areas, bathrooms, toilet rooms and habitable basement areas shall have a minimum clear ceiling height of seven feet (2134 mm). (1) Exceptions: Rooms occupied exclusively for sleeping or similar purposes and having a sloped ceiling over all or part of the room, with a minimum clear ceiling height of seven feet (2134 mm) over a minimum of one-third of the required minimum floor area. In calculating the floor area of such rooms, only those portions of the floor area with a minimum clear ceiling height of five feet (1524 mm) shall be included. (d) Bedroom and living room requirements. Every bedroom and living room shall comply with the requirements of Sections 10-253(b)(1) through 10-253(b)(4). (1) Access from bedrooms. Bedrooms shall not constitute the only means of access to other bedrooms or habitable spaces and shall not serve as the only means of egress from other habitable spaces. (2) Water closet accessibility. Every bedroom shall have access to at least one water closet and one lavatory without passing through another bedroom. (3) Prohibited occupancy. Kitchens and non-habitable spaces shall not be used for sleeping purposes. (4) Other requirements. Bedrooms shall comply with the applicable provisions of this code including, but not limited to, the light, ventilation, ceiling and height requirements of this division; the plumbing facilities and water-heating facilities requirements of Division 6; the heating facilities and electrical receptacle requirements of Division 7; and the smoke detector and emergency escape requirements of Division 8. (e) Efficiency unit. Nothing in this section shall prohibit an efficiency living unit from meeting the following requirements: (1) A unit occupied by not more than one occupant shall have a minimum clear floor area of 120 square feet (11.2 m2). A unit occupied by not more than two occupants shall have a minimum clear floor area of 220 square feet (20.4 m2). A unit occupied by three occupants shall have a minimum clear floor area of 320 square feet (29.7 m2). These required areas shall be exclusive of the areas required by Subsections (2) and (3). (2) The unit shall be provided with a kitchen sink, cooking appliance and refrigeration facilities, each having a minimum clear working space of 30 inches (762 mm) in front. Light and ventilation conforming to this code shall be provided. (3) The unit shall be provided with a separate bathroom containing a water closet, lavatory and bathtub or shower. (4) The maximum number of occupants shall be three. (f) Food preparation. All spaces to be occupied for food preparation purposes shall contain suitable space and equipment to store, prepare and serve foods in a sanitary manner. There shall be adequate facilities and services for the sanitary disposal of food wastes and refuse, including facilities for temporary storage.

(Ord. No. 3403, § 1, 9-13-16)

Ask a question about Thornton law

Corpus searches the Thornton sections it holds and shows the ones that match, with their citations. Free, no sign-in.