§ 10-274 — Electrical equipment
Code of the City of Thornton, Colorado (Supp. No. 65: codified through Ordinance No. 3773, adopted June 9, 2026) · Thornton City Code § 10-274
Corpus is an independent public-information project, not the official City of Thornton website. Stable reference: corpuslaw.us/code/9d3d2d38-f6c0-4d6b-bbaf-30462bae68a6
Sec. 10-274. - Electrical equipment.
(a) Installation. All electrical equipment, wiring and appliances shall be properly installed and maintained in a safe and approved manner. (b) Receptacles. Every laundry area shall contain at least one grounded-type receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall contain at least one receptacle. Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection. All receptacle outlets shall have the appropriate faceplate cover for the location. (c) Luminaires. Every public hall, interior stairway, toilet room, kitchen, bathroom, laundry room, boiler room and furnace room shall contain at least one electric luminaire. Pool and spa luminaries over 15 V shall have ground fault circuit interrupter protection. (d) Wiring. Flexible cords shall not be used for permanent wiring, or for running through doors, windows, or cabinets, or concealed within walls, floors, or ceilings.
(Ord. No. 3403, § 1, 9-13-16)