Sec. 22-311. - Special Flood Hazard Areas outside of floodways.

(a) General standards. General standards for areas within the Special Flood Hazard Area but outside floodways are as follows: (1) Anchoring. a. All new construction and substantial improvements shall be anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads including the effects of buoyancy. b. All manufactured homes shall be elevated and anchored to resist flotation, collapse or lateral movement. Methods of anchoring may include but are not limited to use of over-the-top or frame ties to ground anchors or according to manufacturer's recommendation. This requirement is in addition to applicable state and local anchoring requirements for resisting wind forces. Specific requirements may be: 1. Over-the-top ties to be provided at each of the four corners of the manufactured home with two additional ties per side at intermediate locations. Manufactured homes less than 50 feet in length only require one additional tie per side. 2. Frame ties to be provided at each corner of the manufactured home with five additional ties per side at intermediate locations. Manufactured homes less than 50 feet in length only require four additional ties per side. 3. All components of the anchoring system to be capable of carrying a force of 4,800 pounds. 4. Any additions to the manufactured home to be similarly anchored. (2) Construction materials and methods. a. All new construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage. b. All new construction and substantial improvements shall be constructed using methods and practices that minimize flood damage. (3) Utilities. a. All new and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the system. b. New and replacement sanitary sewer systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems and the discharge from systems into the floodwater. c. On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding. d. Electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities shall be designed and located so as to prevent water from entering or accumulating within the components during conditions of flooding. (4) Fences. Fences in the floodplain shall meet the requirements of Section 22-310(4). (5) Subdivision proposals. a. All subdivisions shall be consistent with the need to minimize flood damage. b. All subdivision proposals shall have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize flood damage. c. All subdivision proposals shall have adequate drainage provided to reduce exposure to flood damage. d. Base flood elevation data shall be provided for subdivision proposals and other proposed development projects, which contain at least 50 lots or five acres, whichever is less. e. Platted lots: 1. Except as provided in subsection 2. below, no portion of any platted lot shall be permitted within areas of special flood hazard. 2. Exceptions may be granted for non-residential lots, on a lot by lot basis if the entire area of the lot, less setbacks and easements, is at least one foot above the base flood elevation and outside the special flood hazard area (SFHA). Such restriction shall be noted on the plat. (6) Recreational vehicles. Recreational vehicles to be placed on a site must; a. Be elevated and anchored to the standards in (b)(3), below; or b. Be on the site for less than 180 consecutive days; or c. Be fully licensed and highway ready. (b) Specific standards. (1) Residential construction. a. New construction and substantial improvement and/or reconstruction of any residential structure shall have the lowest floor (including basement), electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities (including ductwork), elevated to one foot above the base flood elevation. This includes external mechanical and electrical equipment such as air conditioning compressors, meters, and master switches. Upon completion of the structure, the elevation of the lowest floor, including basement, shall be certified by a registered Colorado professional engineer, architect, or land surveyor on the prescribed FEMA form. Such certification shall be submitted to the floodplain administrator for approval and maintained by the floodplain administrator thereafter. b. In addition to the requirement of paragraph a. above, any substantial improvement, renovation, reconstruction or repair of residential structures that are in the special flood hazard area shall be constructed with the lowest floor, including basements, placed with a minimum of one foot of Freeboard above the base flood elevation or model-backed approximate flood elevation. c. All new construction or substantial improvement of residential structures within any AO and AH zone on the FIRM shall be required to have the lowest floor elevated above the highest adjacent grade at least as high as the depth number specified in feet on the FIRM, plus one foot of freeboard, or at least two feet, if no depth number is specified. d. Within zones AO and AH, adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures shall be required. (2) Nonresidential construction. a. With the exception of critical facilities, new construction and substantial improvements of any commercial, industrial, or other nonresidential structure shall either have the lowest floor (including basement), electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities (including ductwork), both internal and external to the structure, elevated to one foot above the base flood elevation or, together with attendant utility and sanitary facilities, be designed so that at one foot above the base flood elevation the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. A registered Colorado professional engineer or architect shall develop and/or review structural design, specifications, and plans for the construction, and shall certify that the design and methods of construction are in accordance with accepted standards of practice as outlined in this subsection. Such certification shall be maintained by the floodplain administrator. b. Substantial improvement, renovation or repair of any commercial, industrial or other nonresidential structures that are in the floodplain of the base flood shall: 1. Be floodproofed so that below and at least one foot above the base flood level the structure is watertight with walls substantially impermeable to the passage of water; 2. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and 3. Be certified by a Colorado professional engineer. The certification shall verify and record the actual elevation, in relation to the NAVD of 1988 or other applicable datum, to which the structure has been floodproofed. c. All new construction or substantial improvement of nonresidential structures, with the exception of Critical Facilities, within any AO and AH zone on the FIRM shall be required to have the lowest floor (including basement), electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities (including ductwork), elevated at least one foot above the highest adjacent grade at least as high as the depth number specified in feet on the FIRM, plus one foot of freeboard, or at least two feet, if no depth number is specified, or together with attendant utility and sanitary facilities, be designed so that the structure is watertight to at least one foot above the base flood level with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads of effects of buoyancy. A registered Colorado Professional Engineer or architect shall submit a certification to the Floodplain Administrator. d. Substantial improvement, renovation or repair of nonresidential structures that are within any AO and AH zone on the FIRM shall be required to be completely floodproofed to that level to meet the floodproofing standards in subsection (b)(2)b. of this section. e. Within zones AO and AH, adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures shall be required. (3) Manufactured homes. a. Manufactured homes shall be anchored as provided in section 22-311 (a)(1). b. All manufactured homes that are placed or substantially improved within zones A1-30, AH, AO, A, and AE shall meet the provisions of paragraph d. below and shall be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated at least one foot above the base flood elevation, and shall be securely anchored to an adequately anchored foundation system as provided in this division to resist flotation, collapse and lateral movement if on the following sites: 1. Outside of a manufactured home park or subdivision; 2. In a new manufactured home park or subdivision; 3. In an expansion to an existing manufactured home park or subdivision; or 4. In an existing manufactured home park or subdivision in which a manufactured home has incurred substantial damage as a result of a flood. c. All manufactured homes that are placed or substantially improved on sites within an existing manufactured home park or subdivision within zones A1-30, AH, AO, A, and AE shall meet the provisions of paragraph d. below and shall be elevated so that either the lowest floor of the manufactured home is at least one foot above the base flood level or the manufactured home chassis is supported by reinforced piers or other foundation elements that are no less than three feet in height above grade, whichever is higher, and shall be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement. d. New construction, substantial improvement, reconstruction or replacement of any manufactured home shall have the lowest floor, electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities (including ductwork), elevated to one foot above the base flood elevation. This includes external mechanical and electrical equipment such as air conditioning compressors, meters, and master switches. Upon completion of the structure, the elevation of the lowest floor, shall be certified by a registered Colorado professional engineer, architect, or land surveyor on the prescribed FEMA form. Such certification shall be submitted to the floodplain administrator for approval. (4) Enclosures. a. New construction and substantial improvements, with fully enclosed areas below the lowest floor that are usable solely for parking of vehicles, building access, or storage in an area other than a crawlspace, and which are below the base flood elevation shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. b. Designs for meeting this requirement must be certified by either a registered Colorado professional engineer or architect or meet or exceed the following minimum criteria: 1. A minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. 2. The bottom of all openings shall be no higher than one-foot above grade. 3. Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of floodwaters and do not reduce the net open space below the ratio specified in 1. above. (5) Critical facilities. a. Classification of critical facilities. It is the responsibility of the city to identify and confirm that specific structures in their community meet the following criteria: 1. Essential services facilities include public safety, emergency response, emergency medical, designated emergency shelters, communications, public utility plant facilities, and transportation lifelines. These facilities consist of: i. Public safety (police stations, fire and rescue stations, emergency vehicle and equipment storage, and, emergency operation centers); ii. Emergency medical (hospitals, ambulance service centers, urgent care centers having emergency treatment functions, and non-ambulatory surgical structures but excluding clinics, doctors' offices, and non-urgent care medical structures that do not provide these functions); iii. Designated emergency shelters; iv. Communications (main hubs for telephone, broadcasting equipment for cable systems, satellite dish systems, cellular systems, television, radio, and other emergency warning systems, but excluding towers, poles, lines, cables, and conduits); v. Public utility plant facilities for generation and distribution (hubs, treatment plants, substations and pumping stations for water, power and gas, but not including towers, poles, power lines, buried pipelines, transmission lines, distribution lines, and service lines); and vi. Air Transportation lifelines (airports (municipal and larger), helicopter pads and structures serving emergency functions, and associated infrastructure (aviation control towers, air traffic control centers, and emergency equipment aircraft hangars). 2. Specific exemptions to this category include wastewater treatment plants (WWTP), non-potable water treatment and distribution systems, and hydroelectric power generating plants and related appurtenances. 3. Public utility plant facilities may be exempted if it can be demonstrated to the satisfaction of the floodplain administrator that the facility is an element of a redundant system for which service will not be interrupted during a flood. At a minimum, it shall be demonstrated that redundant facilities are available (either owned by the same utility or available through an intergovernmental agreement or other contract) and connected, the alternative facilities are either located outside of the 100-year floodplain or are compliant with the provisions of this article, and an operations plan is in effect that states how redundant systems will provide service to the affected area in the event of a flood. Evidence of ongoing redundancy shall be provided to the floodplain administrator on an as-needed basis upon request. 4. Hazardous materials facilities include facilities that produce or store highly volatile, flammable, explosive, toxic and/or water-reactive materials. These facilities may include; i. Chemical and pharmaceutical plants (chemical plant, pharmaceutical manufacturing); ii. Laboratories containing highly volatile, flammable, explosive, toxic and/or water-reactive materials; iii. Refineries; iv. Hazardous waste storage and disposal sites; and v. Above ground gasoline or propane storage or sales centers. 5. Facilities shall be determined to be critical facilities if they produce or store materials in excess of threshold limits. If the owner of a facility is required by the Occupational Safety and Health Administration (OSHA) to keep a material safety data sheet (MSDS) on file for any chemicals stored or used in the work place, AND the chemical(s) is stored in quantities equal to or greater than the threshold planning quantity (TPQ) for that chemical, then that facility shall be considered to be a critical facility. The TPQ for these chemicals is either 500 pounds or the TPQ listed (whichever is lower) for extremely hazardous chemicals listed under 40 CFR §§ 302 (2010) and subsequent amendments; or 10,000 pounds for any other chemical. Specific exemptions to this category include: i. Finished consumer products within retail centers and households containing hazardous materials intended for household use, and agricultural products intended for agricultural use. ii. Buildings and other structures containing hazardous materials for which it can be demonstrated to the satisfaction of the local authority having jurisdiction by hazard assessment and certification by a qualified professional (as determined by the local jurisdiction having land use authority) that a release of the subject hazardous material does not pose a major threat to the public. iii. Pharmaceutical sales, use, storage, and distribution centers that do not manufacture pharmaceutical products. iv. These exemptions shall not apply to buildings or other structures that also function as critical facilities under another category outlined in this article. 6. At-risk population facilities include medical care, congregate care, and schools. These facilities may include: i. Elder care (nursing homes); ii. Congregate care serving 12 or more individuals (day care and assisted living); iii. Public and private schools (pre-schools, K-12 schools), before school and after-school care serving 12 or more children); 7. Facilities vital to restoring normal services including government operations. These facilities may include: i. Essential government operations (public records, courts, jails, building permitting and inspection services, community administration and management, maintenance and equipment centers); ii. Essential structures for public colleges and universities (dormitories, offices, and classrooms only). iii. These facilities may be exempted if it is demonstrated to the floodplain administrator that the facility is an element of a redundant system for which service will not be interrupted during a flood. At a minimum, it shall be demonstrated that redundant facilities are available (either owned by the same entity or available through an intergovernmental agreement or other contract), the alternative facilities are either located outside of the 100-year floodplain or are compliant with this article, and an operations plan is in effect that states how redundant facilities will provide service to the affected area in the event of a flood. Evidence of ongoing redundancy shall be provided to the floodplain administrator on an as-needed basis upon request. b. Protection for critical facilities. All new, substantially damaged and substantially improved critical facilities and new additions to critical facilities located within the SFHA shall be regulated to a higher standard than structures not determined to be critical facilities. For the purposes of this article, protection shall include one of the following: 1. Location outside the SFHA; or 2. Elevation or flood proofing of the structure to at least two feet above the base flood elevation. c. Ingress and egress for new critical facilities. New critical facilities shall, when practicable as determined by the floodplain administrator, have continuous non-inundated access (ingress and egress for evacuation and emergency services) during a 100-year flood event. (6) Encroachments. No new construction, substantial improvements, or other developments, including fill, shall be permitted unless it is demonstrated that the cumulative effect of the proposed development, when combined with all other existing and anticipated development, will not increase the water surface elevation of the base flood more than one-half foot (0.50-foot) at any point within the community.

(Ord. No. 3737, § 5, 8-12-25)

Ask a question about Thornton law

Corpus searches the Thornton sections it holds and shows the ones that match, with their citations. Free, no sign-in.