15.44.150 - Provisions for flood hazard reduction.

A. General Standards. In all areas of special flood hazards the following standards are required: 1. Anchoring. a. All new construction and substantial improvements shall be anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. 2. Construction Material and Methods. a. All new construction and substantial improvements shall be constructed with materials resistant to flood damage; b. All new construction and substantial improvements shall be constructed by methods and practices that minimize flood damages. 3. Utilities. a. Electrical, heating, ventilation, plumbing, air conditioning equipment and other service facilities shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding; b. All new and replacement water supply systems shall be designed to minimize or eliminate infiltration of flood waters into the system; c. New and replacement sanitary sewerage systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems and discharge from the systems into floodwaters; and d. On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding. 4. Subdivision Proposals. a. All subdivision proposals shall be consistent with the need to minimize flood damage; b. All subdivision proposals shall have public utilities and facilities such as a sewer, gas, electrical and water systems located and constructed to minimize flood damage; c. All subdivision proposals shall have adequate drainage provided to reduce exposure to flood damage; and d. Base flood elevation data shall be provided for subdivision proposals and other proposed development which contain at least fifty (50) lots or five acres (whichever is less). 5. Manufactured Homes. a. All manufactured homes (including recreational vehicles placed on a site for one hundred eighty (180) consecutive days or longer) to be placed, or substantially improved, shall be installed using methods and practices which minimize flood damage. They shall also be elevated and anchored to resist flotation, collapse and lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties; b. Elevation construction standards include piling foundations placed no more than ten feet apart, and reinforcement is provided for piers more than six feet above ground level. B. Specific Standards. In all areas of special flood hazards where base flood elevation data has been provided as set forth in Section 15.44.060, basis for establishing the areas of special flood hazard or in Section 15.44.030.B. Use of other base flood data, the following standards are required: 1. Residential Construction. a. New construction and substantial improvement of any residential structure shall have the lowest floor, including basement, elevated to or above base flood elevation. 2. Manufactured Homes in Zone A and AE. a. All manufactured homes (including recreational vehicles placed on a site for one hundred eighty (180) consecutive days or longer) to be placed, or substantially improved, shall be elevated so that the lowest floor is above the base flood elevation. This includes manufactured homes located outside a manufactured home park or subdivision, in a new manufactured home park or subdivision, in an expansion to an existing manufactured home park or subdivision, or on a site in an existing manufactured home park or subdivision in which a manufactured home has incurred substantial damage as a result of a flood; b. It shall be placed on a permanent foundation which itself is securely anchored and to which the structure is securely anchored so that it will resist flotation, lateral movement and hydrostatic and hydrodynamic pressures. Anchoring may include, but not be limited to, the use of over-the-top or frame ties to ground anchors; c. It shall be installed using methods and practices which minimize flood damage; d. Adequate access and drainage should be provided. e. Recreational vehicles shall either be on site for fewer than one hundred eighty (180) consecutive days, and be fully licensed and ready for highway use, or meet all the general standards of Section 15.44.150.A., and the elevation and anchoring requirement of Sections 15.44.150.A.5.a. and b., and 15.44.150.B.2.a., b., c. and d. for a manufactured home. A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions. 3. Nonresidential Construction. New construction and substantial improvement of any commercial, industrial or other nonresidential structure shall either have the lowest floor, including basement, elevated to the level of the base flood elevation; or, together with attendant utility and sanitary facilities, shall: a. Be floodproofed so that below an elevation of one foot above the base flood level the structure is watertight with walls substantially impermeable to the passage of water; b. Have structural components capable of resisting hydrostatic and hydronamic loads and effects of buoyancy; and c. Be certified by a registered professional engineer or architect that the design and methods of construction are in accordance with acceptable standards of practice for meeting the provisions of this subsection. Such certifications shall be provided to the official as set forth in Section 15.44.130.C.2. 4. Enclosed Areas Below Base Flood Elevation—A and AE Zones. New construction, or substantial improvements, of elevated buildings that include fully enclosed areas formed by foundation and other exterior walls below the base flood elevation shall be designed to preclude finished living space and designed to allow for the entry and exit of floodwaters to automatically equalize hydrostatic flood forces on exterior walls. a. Designs for complying with this requirement must either be certified by a professional engineer or architect, or meet the following minimum criteria: i. Provide a minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding; ii. The bottom of all openings shall be no higher than one foot above grade; and iii. Openings may be equipped with screens, louvers, valves or other coverings or devices provided they permit the automatic flow of floodwater in both directions. b. Electrical, plumbing and other utility connections are prohibited below the base flood elevation; c. Access to the enclosed area shall be the minimum necessary to allow for parking of vehicles (garage door) or limited storage of maintenance equipment used in connection with the premises (standard exterior door) or entry to the living area (stairway or elevator); and C. Coastal High Hazard Area. Coastal high hazard areas (VE zones) are located within the areas of special flood hazard established in Section 15.44.060. These areas have special flood hazards associated with high velocity waters from tidal surges and hurricane wave wash; therefore, the following provisions shall apply: 1. Location of Structures. a. All new buildings, structures or substantial improvements shall be located landward of reach of the mean high tide. 2. Construction Methods. a. Elevation. All new buildings, structures or substantial improvements shall be elevated so that the lowest supporting member (excluding pilings or columns) is located no lower than the base flood elevation level, with all space below the lowest supporting member open so as not to impede the flow of water, except for breakaway walls as provided for in Section 15.44.150.C.2.d. b. Structural Support. i. All new buildings, structures or substantial improvements shall be securely anchored on pilings or columns. ii. All pilings and columns and the attached structures shall be anchored to resist flotation, collapse and lateral movement due to the effect of wind and water loads acting simultaneously on all building components. The anchoring and support system shall be designed with wind and water loading values which equal or exceed the one-hundred-year mean recurrence interval (one percent annual chance floods and winds). iii. There shall be no fill used for structural support. c. Certification. Compliance with the provisions of subsection C.2.a. and b. of this section shall be certified by a registered professional engineer or architect including design specifications and plans for construction. d. Space Below the Lowest Floor. i. Any alteration, repair, reconstruction or improvement to a structure started after the enactment of the ordinance codified in this chapter shall not enclose the space below the lowest floor unless breakaway walls are used as provided for in this section. ii. Nonsupporting breakaway wall, lattice work or mesh screening shall be allowed below the base flood elevation provided they are not a part of the structural support of the building and are designed so as to break away, under abnormally high tides or wave action, without damage to the structural integrity of the building on which they are to be used and provided the following design specifications are met: (A) Design-safe loading resistance of each wall shall not be less than ten nor more than twenty (20) pounds per square foot; or (B) If more than twenty (20) pounds per square foot, a registered professional engineer or architect shall certify that the design wall collapse would result from a water load less than that which would occur during the base flood event, and the elevated portion of the building and supporting foundation system shall not be subject to collapse, displacement or other structural damage due to the effects of wind and water loads acting simultaneously on all building components during the base flood event. Maximum wind and water loading values to be used in this determination shall each have one percent chance of being equalled or exceeded in any given year (one-hundred-year mean recurrence interval). iii. If breakaway walls are utilized, such enclosed space shall not be used for human habitation, but shall be designed to be used only for parking of vehicles, building access or limited storage of maintenance equipment used in connection with the premises. iv. Prior to construction, plans for any structure that will have breakaway walls must be submitted to the city engineer for approval. v. Any alteration, repair, reconstruction or improvement to a structure shall not enclose the space below the lowest floor except with breakaway walls, lattice work or screening as provided for in subsection C.2.d.(ii)(A) and (B) of this section. 3. Manufactured Homes in VE Zones. a. All manufactured homes (including recreational vehicles placed on a site for one hundred eighty (180) consecutive days or longer) to be placed, or substantially improved, shall be elevated so that the lowest structural member is above the base flood elevation and meet the construction requirements of Section 15.44.150.C.1. and 2. This includes manufactured homes located outside a manufactured home park or subdivision, in an existing manufactured home park or subdivision, in a new manufactured home park or subdivision, in an expansion to an existing manufactured home park or subdivision, or on a site in an existing manufactured home park in which a manufactured home has incurred substantial damage as a result of a flood; b. It shall be placed on a permanent foundation which itself is securely anchored and to which the structure is securely anchored so that it will resist flotation, lateral movement and hydrostatic and hydrodynamic pressures. Anchoring may include, but not be limited to, the use of over-the-top or frame ties to ground anchors; c. It shall be installed using methods and practices which minimize flood damage; d. Adequate access and drainage should be provided. e. Recreational vehicles shall either be on site for fewer than one hundred eighty (180) consecutive days, and be fully licensed and ready for highway use, or meet all the general standards of Section 15.44.150.A., and the elevation and anchoring requirement of Sections 15.44.150.A.5.a. and b., and 15.44.150.B.2.a., b., c. and d. for a manufactured home. A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions. 4. Sand Dunes. There shall be no alteration of sand dunes which would increase potential flood damage. D. Floodways. Located within areas of special flood hazard established in Section 15.44.060 are areas designated under Section 15.44.130.B as floodways. Since the floodway is an extremely hazardous area due to the velocity of floodwaters which carry debris, potential projectiles and erosion potential, the following provisions apply: 1. Encroachments. Prohibit encroachments including fill, new construction, substantial improvements and other development unless certification, with a supporting technical data, by a registered professional engineer is provided demonstrating, through hydrologic and hydraulic analyses performed in accordance with standard engineering practice, that encroachments shall not result in any (0.00) increase in flood levels during the occurrence of the base flood discharge. 2. In A zones where base flood elevations have been determined, but before a floodway is designated, no new construction, substantial improvement or other development (including fill) shall be permitted which will increase base flood elevations more than one foot at any point along the watercourse when all anticipate development is considered cumulatively with the proposed development. 3. The city may request floodway data of an applicant for watercourses without FEMA-published floodways. When such data is provided by an applicant or whenever such data is available from any other source (in response to the city's request or not), the city shall adopt a regulatory floodway based on the principle that the floodway must be able to convey the waters of the base flood without increasing the water surface elevation more than one foot at any point along the watercourse. E. Equal Conveyance. Within the floodplain, except in those areas which are tidally influenced, as designated on the flood insurance rate map (FIRM) for the community, encroachments resulting from filling, new construction or substantial improvements involving an increase in footprint of the structure, are prohibited unless the applicant provides certification by a registered professional engineer demonstrating, with supporting hydrologic and hydraulic analyses performed in accordance with standard engineering practice, that such encroachments shall not result in any (0.00 feet) increase in flood levels (base flood elevation). Work within the floodplain and the land adjacent to the floodplain, including work to provide compensatory storage shall not be constructed in such a way to cause an increase in flood stage or flood velocity. F. Compensatory Storage. The water holding capacity of the floodplain, except those areas which are tidally influenced, shall not be reduced. Any reduction caused by filling, new construction or substantial improvements involving an increase in footprint to a structure, shall be compensated for by deepening and/or widening of the floodplain. Storage shall be provided on site, unless easements have been gained from adjacent property owners; it shall be provided within the same hydraulic reach and a volume not previously used for flood storage; it shall be hydraulically comparable and incrementally equal to the theoretical volume of floodwater at each elevation, up to and including one-hundred-year flood elevation, which would be displaced by the proposed project. Such compensatory volume shall have an unrestricted hydraulic connection to the same waterway or water body. Compensatory storage can be provided off-site if approved by the municipality. G. Aboveground Storage Tanks. Aboveground storage tanks (oil, propane, etc) which are located outside or inside of a structure must either be elevated above the base flood elevation (BFE) on a concrete pad, or be securely anchored with tie down straps to prevent flotation or lateral movement, have the top of the fill pipe extended above the BFE, and have a screw cap that does not allow for the infiltration of flood water. H. Portion of Structure in a Flood Zone. If any portion of a structure lies within the special flood hazard area (SFHA), the entire structure is considered to be in the SFHA. The entire structure must meet the requirements of the flood zone. This includes any additions made to the main structure. I. No Structures Entirely or Partially Over Water. New construction, substantial improvement and repair to structure that have sustained damage cannot be constructed or located entirely or partially over water unless it is a functionally dependent use or facility.

(Ord. dated 4/1/13)

Ask a question about Bridgeport law

Corpus searches the Bridgeport sections it holds and shows the ones that match, with their citations. Free, no sign-in.