For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 4.19.1 — ENTRANCE TYPES

Code of Ordinances of the City of Hartford, Connecticut (Supp. No. 119: codified through Ordinance of May 11, 2026) · Hartford Zoning Regulations § 4.19.1

Corpus is an independent public-information project, not the official City of Hartford website. Stable reference: corpuslaw.us/code/32c3bd60-65b0-4953-9948-ae1ecbda5ffa

4.19.1 - ENTRANCE TYPES

Entrance type standards apply to the ground story and visible basement of front facades of all building types as defined in this Section. Refer to the Building Type Table Requirements, sections 4.3 through 4.16. A. General. The following provisions apply to all entrance types. (1) Intent. To guide the design of the ground story of all buildings to relate appropriately to pedestrians on the street. Treatment of other portions of the building facades is detailed in each Building Type Table (refer to Building Types 4.3 through 4.16). (2) Applicability. The entire ground story street-facing facade(s) of all buildings shall fulfill the requirements of at least one of the permitted entrance types, unless otherwise stated. (3) Measuring Transparency. Refer to Figure 4.18-F Measuring Transparency for information on measuring building transparency. (4) Visible Basements. Visible basements, permitted by entrance type, are optional. The visible basement shall be a maximum of one-half the height of the tallest story. Figure 4.19-A Storefront Entrance Type [image omitted; see the official code] B. Storefront Entrance Type. (Refer to Figure 4.19-A Storefront Entrance Type.) The Storefront entrance type is a highly transparent ground story treatment designed to serve primarily as the display area and primary entrance for retail or service uses. (1) Transparency. Minimum transparency is required per building type. (2) Elevation. Storefront entrance threshold elevation shall be between zero and one foot above sidewalk. (3) Visible Basement. A visible basement is not permitted. (4) Horizontal Facade Division. Horizontally define the ground story facade from the upper stories with an expression line. (5) Entrance. Entries may be recessed from the front facade closest to the street. (a) Any recessed entrance shall be a minimum of 3 feet and a maximum of 8 feet deep, measured from the portion of the front facade closest to the street. (b) When the recessed entrance falls behind the front build-to zone, the recess shall be no wider than 8 feet. Figure 4.19-B Arcade Entrance Type [image omitted; see the official code] C. Arcade Entrance Type. (Refer to Figure 4.19-B Arcade Entrance Type.) An Arcade entrance type is a covered pedestrian walkway within the recess of a ground story. (1) Arcade. An open-air public walkway is required from the face of the building recessed into the building a minimum of 8 and a maximum of 15 feet. (2) Build-to Zone. When the Arcade is utilized, the outside face of the Arcade shall be considered the front facade, located within the required build-to zone. (3) Interior Facade. Storefront entrance type is required on the interior ground story facade provided, however, that the requirement to recess such entrance in 4.19.1 B.(5) does not apply. (4) Column Spacing. Columns shall be spaced between 10 feet and 12 feet on center. (5) Column Width. Columns shall be a minimum of 1'-8" and a maximum 2'-4" in width. (6) Arcade Opening. Opening shall not be flush with interior arcade ceiling and may be arched or straight. (7) Horizontal Facade Division. Horizontally define the ground story facade from the upper stories with an expression line. (8) Visible Basement. A visible basement is not permitted. Figure 4.19-C Stoop Entrance Type [image omitted; see the official code] D. Stoop Entrance Type. (Refer to Figure 4.19-C Stoop Entrance Type.) A stoop is an unroofed, open platform. (1) Stoop Size. Stoops shall be a minimum of 4 feet deep and 6 feet wide. (2) Elevation. Stoop elevation shall be located a maximum of 2'-6" above the sidewalk without visible basement and a maximum of 4'-6" above the sidewalk with a visible basement. (3) Visible Basement. A visible basement is permitted and shall be separated from the ground story by an expression line. (4) Entrance. All front facade entries shall be located off a stoop. (5) Encroachment. Refer to 4.18.1 D.(1) Encroachments. Figure 4.19-D Porch Entrance Type [image omitted; see the official code] E. Porch Entrance Type. (Refer to Figure 4.19-D Porch Entrance Type.) A porch is a raised, roofed platform that may or may not be enclosed on all sides. If enclosed, the space shall not be climate controlled. (1) Transparency. (a) Minimum transparency per building type is required. (b) If enclosed, a minimum of 40 percent of the enclosed porch shall be comprised of highly transparent, low reflectance windows. (2) Porch Size. The porch shall be a minimum of 5 feet deep and 8 feet wide. (3) Elevation. Porch elevation shall be located a maximum of 2'-6" above the sidewalk without a visible basement and a maximum of 4'-6" above the sidewalk with a visible basement. (4) Visible Basement. A visible basement is permitted. (5) Height. Porches up to 3 stories are permitted for Apartment Building or Stacked Flats Building Types, up to 2 stories for Row and House Building Types, and one story for Cottage Commercial Building Types. An upper story of any porch structure which is used either as an open-air balcony or as a roofed balcony or porch counts as a story when calculating the number of stories of the porch. (6) Entrance. All front facade entries shall be located off a porch. (7) Encroachment. Refer to 4.18.1 D.(1) Encroachments. (8) Heat and Use. No facilities for providing heat shall be permitted on a porch, and a porch shall not be used as a sleeping room.

Ask a question about Hartford law

Corpus searches the Hartford sections it holds and shows the ones that match, with their citations. Free, no sign-in.