Roof type standards apply to the roof and cap of all building types as defined in this section. Refer to sections 4.3 through 4.16 Building Types. A. General Provisions. The following provisions apply to all roof types. (1) Intent. To guide the design of the cap of all buildings. (2) Applicability. All buildings shall fulfill the requirements of one of the roof types permitted for the building type. (3) Measuring Height. Refer to 4.18.2 Height for information on measuring building height. (4) Other Roof Types. Other building caps not listed as a specific type may be made by a request to the zoning administrator with the following requirements: (a) The roof type shall not create additional occupiable space beyond that permitted by the building type. (b) The shape of the roof type shall be significantly different from those defined in this section 4.19.2 Roof Types, i.e. a dome, spire, vault. (c) The building shall warrant a separate status within the community from the fabric of surrounding buildings, with a correspondence between the form of the roof type and the meaning of the building use. B. Parapet Roof Type. (Refer to Figure 4.19-E Parapet Roof Type) A parapet is a low wall projecting above a building's roof along the perimeter of the building. It can be utilized with a flat or low pitched roof and also serves to limit the view of roof-top mechanical systems from the street. Figure 4.19-E Parapet Roof Type [image omitted; see the official code] (1) Parapet Height. Height is measured from the top of the upper story to the top of the parapet. (a) Minimum height is 2 feet with a maximum height of 6 feet. (b) Roof appurtenances shall be located a distance behind the parapet so as not to be visible from any street sidewalk. (2) Horizontal Expression Lines. An expression line shall define the parapet from the upper stories of the building and shall also define the top of the cap. (3) Occupied Space. Occupied space shall not be incorporated behind this roof type. C. Pitched Roof Type. (Refer to Figure 4.19-F Pitched Roof Types.) This roof type has a sloped or pitched roof. Slope is measured with the vertical rise divided by the horizontal span or run. (1) Pitch Measure. The roof may not be sloped less than a 4:12 (rise:run) or more than 16:12. Figure 4.19-F Pitched Roof Types [image omitted; see the official code] (a) Slopes less than 4:12 are permitted to occur on second story or higher roofs. (2) Configurations. (a) Hipped, gabled, and combination of hips and gables with or without dormers are permitted. (b) Butterfly roofs (inverted gable roof) are permitted with a maximum height of 8 feet, inclusive of overhang. (c) Gambrel roofs and mansard roofs are permitted only on House Types A, B, and C and the Stacked Flats Building Type. (3) Parallel Ridge Line. A gabled end or perpendicular ridge line shall occur at least every 100 feet of roof when the ridge line runs parallel to the front lot line. (Refer to Figure 4.19-F Pitched Roof Types.) (4) Roof Height. Roofs without occupied space and/or dormers shall have a maximum height on street-facing facades equal to the maximum floor height permitted for the building type. (5) Occupied Space. Occupied space may be incorporated behind this roof type. D. Flat Roof Type. (Refer to Figure 4.19-G Flat Roof Type.) This roof type has a flat roof with overhanging eaves. (1) Configuration. Roofs with no visible slope are acceptable. Eaves are required on all street facing facades. (2) Eave Depth. Eave depth is measured from the building facade to the outside edge of the eave. Eaves shall have a depth of at least 14 inches. (3) Eave Thickness. Eave thickness is measured at the outside edge of the eave, from the bottom of the eave to the top of the eave. Eaves shall be a minimum of 8 inches thick. Figure 4.19-G Flat Roof Type [image omitted; see the official code] (4) Interrupting Vertical Walls. Vertical walls may interrupt the eave and extend above the top of the eave with no discernible cap. (a) No more than one-half of the front facade can consist of an interrupting vertical wall. (b) Vertical walls shall extend no more than 4 feet above the top of the eave. (5) Occupied Space. Occupied space shall not be incorporated behind this roof type. E. Towers. (Refer to Figure 4.19-H Tower.) When utilized, a tower must be used in conjunction with other roof types. (1) Quantity. All building types, with the exception of the Civic Building, are limited to one tower per building. (2) Tower Height. Maximum height, measured from the top of the parapet or eave to the top of the tower, is the equivalent of the height of one upper floor of the building to which the tower is applied. (3) Tower Width. Maximum width along all facades is one-third the width of the front facade or 30 feet, whichever is less. (4) Horizontal Expression Lines. An expression line shall define the tower from the upper stories, except on House or Row Building Types. (5) Occupied Space. Towers may be occupied by the same uses allowed in upper stories of the building type to which it is applied. (6) Application. May be combined with all other roof types. (7) Tower Cap. The tower may be capped by the parapet, pitched, or flat roof types may cap the tower. Figure 4.19-H Tower [image omitted; see the official code]

Ask a question about Hartford law

Corpus searches the Hartford sections it holds and shows the ones that match, with their citations. Free, no sign-in.