Sec. 50-25. - Inspections.
The floodplain administrator shall make periodic inspections of development permitted in special flood hazard areas, at appropriate times throughout the period of construction in order to monitor compliance. In addition to the inspections required by the building code, such inspections may include: (1) Stake-out inspection, to determine location on the site relative to the special flood hazard area and floodway. (2) Foundation inspection, upon placement of the lowest floor and prior to further vertical construction, to collect information or certification of the elevation of the lowest floor. (3) Enclosure inspection, including crawlspaces, to determine compliance with applicable provisions. (4) Utility inspection, upon installation of specified equipment and appliances, to determine appropriate location with respect to the base flood elevation. (5) Storage of materials.
(Ord. No. 2014-09, 6-9-2014)