§ 3 — BACKFLOW PREVENTION ASSEMBLIES, DEVICES, AND METHODS
City Code of the City of Milford, Delaware (Supplement 29 Update 1 (2025-01-27)) · Milford City Code, App. C, § 3
Corpus is an independent public-information project, not the official City of Milford website. Stable reference: corpuslaw.us/code/fc99bd4f-a949-47ce-bf9d-433a978a3ffe
§ 3. - BACKFLOW PREVENTION ASSEMBLIES, DEVICES, AND METHODS
3.1 Approved Backflow Prevention Assemblies, Devices and Methods 1) The City of Milford accepts American Society of Sanitary Engineers (ASSE) recognized backflow prevention devices, assemblies, and methods appropriate to the level of hazard as recognized by the applicable Delaware Statutes, Rules, and Regulations. 2) Installation of all backflow prevention, including but not limited to Reduced Pressure Backflow Prevention (RPBP) and Double Check Valve (DCV) assemblies, must conform to the applicable ASSE Standards, most recent versions. 3.2 Responsibility of the Property Owner 1) The Property Owner shall be responsible for the protection of the public water system from pollution or contamination due to backflow through water service connection(s). 2) The Property Owner shall be responsible for the elimination of all unprotected cross-connections, including but not limited to, any service line protection and any connections downstream of the service line supply to the premises. 3) Installation and maintenance of backflow prevention assemblies, devices, and methods at all non-residential premises to protect existing cross-connections shall be the responsibility of the Property Owner. • For residential premises, residential dual checks (RDC) installed on the public water system service line at the water meter. For new construction, the Property Owner/Developer will be responsible for purchasing and installing the RDC. • Where there are three (3) or more living units in a structure, this shall be considered an Apartment Building and categorized as commercial. Section 3.4 below shall apply. 4) At any premises connected to the City of Milford public water system, the installation and maintenance of backflow prevention installed to protect against cross-connections in accordance with Section 3.6 of this chapter, shall be the responsibility of the Property Owner. 5) For all work required by the City or their Agent, including but not limited to installation, alteration, replacement, relocation or repair of backflow prevention assemblies, devices or methods, the Property Owner shall be responsible for obtaining an approved City of Milford permit through the offices of the Department of Planning in accordance with Milford Code of Ordinances Article XIII, Chapter §230-61.F - Required zoning permits and certification as well as Chapter §222-4 - Connection to the City water system. The City reserves the right to direct and administer testing and/or maintenance of any backflow prevention assemblies or devices. All costs associated with testing and any necessary installation, alteration, replacement, relocation, maintenance or repairs of these assemblies or devices shall be the sole responsibility of the Property Owner. If, in the interest of public safety and safety of the water system, the City assumes the responsibility of backflow assembly or device installation, testing, maintenance, alteration, relocation or repair at a premises, all costs for such will be charged to the Property Owner in a manner deemed appropriate by the City. 3.3 Non-Residential Containment Backflow Prevention Assembly Protection With respect to backflow prevention assemblies installed at the service line, the City will require the following for non-residential premises: 1) Containment shall be required as outlined in the CCC Code, or as required by the City. 2) Backflow prevention assemblies shall be installed immediately downstream of the water meter and prior to the first branch line in the plumbing system. 3) Non-residential service line backflow prevention assemblies shall be DCVs or RPBPs, as determined by the City. 4) All high hazard non-residential customers are required to have, at a minimum, a RPBP installed immediately after the water meter and prior to the first branch line in the plumbing system. See the CCC Code, Section 21.2.4.2, most recent version, for further information on high hazard designations (Del. C .16 § 4462 Public Drinking Water Systems (delaware.gov)). 5) Pressure Vacuum Breaker (PVB) assemblies and Atmospheric Type Vacuum Breakers (AVB) shall not be installed as containment. 6) Testable backflow prevention assemblies are prohibited to be installed below grade or in an underground pit. • If the Property Owner or their designee determines that installing the assembly above grade is not feasible, they can contact the City per Addendum A. The City shall review on a case-by-case basis. 7) Where a backflow prevention assembly is required, the Property Owner shall also install appropriate protection from thermal expansion within the premises, when necessary. 3.4 Residential Containment Backflow Prevention Assembly Protection As a minimum requirement, all new residential properties connected to the City of Milford public water system shall have a RDC installed at the water meter located outside on the premises on the public water system service line, per the City of Milford Water Code Chapter 222 in its entirety. The RDCs shall be installed downstream of the water meter. For new construction, the Property Owner/Developer will be responsible for purchasing and installing the RDC. 3.5 Additional Requirements For non-residential and residential premises being served by the City of Milford public water system, there are additional requirements noted below. If backflow prevention is required to be installed per these requirements, the Property Owner must comply with Section 3.1 through 3.4, when applicable. Backflow prevention must be installed in accordance with the applicable ASSE standard, the applicable portions of the International Plumbing Code (IPC) as adopted by the City of Milford or as required to be administered by the municipality per Delaware code, and the manufacturers' installation requirements, most recent version. 1) Lawn Irrigation Systems Specific lawn irrigation systems connected to the City of Milford public water system shall be protected against backflow. For in ground and chemical injection lawn irrigation systems, separate backflow prevention in the form of a RPBP or PVB, shall be installed on the water service line where the service line branches off to supply the irrigation system. 2) Reclaimed Water and/or Auxiliary Water System(s) Those premises that are connected to the City of Milford public water system that are also served by reclaimed water or auxiliary water system(s) shall have a RPBP installed on the water service line downstream of the meter but prior to the first branch line. 3) Swimming Pools Swimming pools connected to the City of Milford public water system shall be protected against backflow. Separate backflow prevention in the form of a RPBP or PVB is required on the water service line where the service line branches off to supply the swimming pool. 4) Fire Suppression Systems Those premises which have a fire suppression system connected to the public water system shall be equipped with appropriate backflow prevention. Fire suppression systems shall be independently protected against backflow by appropriate backflow prevention. The installation of the backflow prevention on a fire suppression system, of whatever sort, shall be installed in such a way as to not adversely affect the operation of the fire suppression system. They must be installed in accordance with the fire authority jurisdiction of the City of Milford. 5) Other If the premises does not qualify under Section 3.6, 1) through 4) above, but is determined to exceed a low-level hazard, the City has the right to require the installation of the appropriate backflow prevention commensurate with the degree of hazard at the premises to protect the public water system. 3.6 Other Service Types 1) Temporary Water Services Temporary connections to the public water system shall have the appropriate backflow prevention as approved by the City. Contact the City per Addendum A for review. 2) Water Trucks and Mobile Equipment Unauthorized use of the public water system for direct fill up of water reservoirs, tanks, or comparable equipment on vehicles and mobile equipment is strictly prohibited and may be subject to fees or fines in accordance with the Milford Code of Ordinances, Addendum F Fees and Fines, Chapter 110. Use of the public water system for direct fill up is permissible if and only if the request and the proposed backflow prevention is approved by the City. Contact the City per Addendum A for review. 3) Tall Buildings Buildings that contain plumbing that meets or exceeds thirty (30) feet in elevation above the water main, where the service line taps the water main, shall be required to have, at a minimum, backflow prevention in the form of a DCV. 3.7 Testing of Backflow Prevention Assemblies 1) All testable backflow prevention assemblies, including residential backflow prevention assemblies, shall be tested upon installation, repair, relocation, after a reported backflow incident, on an annual basis. Assemblies must be tested in accordance with the applicable ASSE standard, the applicable portions of the International Plumbing Code (IPC) as adopted by the City of Milford or as required to be administered by the municipality per Delaware code, and the manufacturers' installation requirements, most recent version. 2) Equipment, such as three and five hose test gauges, used to field test assemblies must be certified and calibrated for accuracy annually. Single hose testing is prohibited. 3) Assembly test forms to record test results will be maintained by the Property Owner and shall be submitted and filed in a location as directed by the City or their Agent. 4) The Property Owner shall have all assemblies tested by a certified Tester having completed the applicable forty (40) hour ASSE Backflow Prevention Assembly Tester Training and Certification Course. All Testers must also complete a recertification exam at an interval not to exceed once every three (3) years. • For fire suppression systems, the Tester shall be a licensed public fire protection company approved and listed on the State of Delaware office of the State Fire Marshal's most recent listing. 3.8 Assembly and Device Abbreviation List Backflow Prevention Assembly and Device Legend A.S.S.E Standard | Legend | Acronym | Testable Device 1001 | Atmospheric Type Vacuum Breakers | AVB | No 1002 | Anti-siphon Fill Valves (Ballcocks) | ASBC | No 1011 | Hose Connection Vacuum Breaker | HBVB | No 1012 | Backflow Preventer w/Intermediate Atmospheric Vent | VDCV | No 1013 | Reduced Pressure Backflow Prevention Assembly | RPBP | Yes 1015 | Double Check Valve Backflow Prevention Assembly | DCV | Yes 1019 | Vacuum Breaker Wall Hydrants | HBIVB | No 1020 | Pressure Vacuum Breaker Assembly | PVB | Yes 1022 | Backflow Preventer for Carbonated Beverage Machine | VMBP | No 1024 | Dual Check Valve Type Backflow Preventers | DC | No 1024 | Residential Dual Check | RDC | Yes/No 1035 | Laboratory Faucet Backflow Preventer | LFVB | No 1037 | Pressurized Flushing Devices (Flushometers) | PFD | No 1047 | RP Detector Backflow Prevention Assembly | RPDA | Yes 1048 | Double Check Detector Backflow Prevention Assembly | DDCV | Yes 1052 | Hose Connection Backflow Preventer | HCBP | No 1055 | Chemical Dispensing Systems | AG | No 1056 | Spill Resistant Vacuum Breaker Assembly | SVB | Yes 1057 | Freeze Resistant Yard Hydrant W/Backflow | No A112.1.2 | Air Gap | AG | No
[Ord. No. 2023-18, § 7, 5-22-2023]
Ask a question about Milford law
Corpus searches the Milford sections it holds and shows the ones that match, with their citations. Free, no sign-in.