For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 4 — SURVEYS OF EXISTING CUSTOMERS

City Code of the City of Milford, Delaware (Supplement 29 Update 1 (2025-01-27)) · Milford City Code, App. C, § 4

Corpus is an independent public-information project, not the official City of Milford website. Stable reference: corpuslaw.us/code/627ed5e5-bed2-4284-9ab9-c27efb5ca0af

§ 4. - SURVEYS OF EXISTING CUSTOMERS

4.1 Responsibility of the Property Owner The Property Owner shall be responsible for participation in the Initial Survey and Site Survey(s) for their premises, when applicable. 4.2 Initial Survey 1) The Initial Survey form will be provided to premises served by the City of Milford public water system to determine the level of hazard existing at the premises and to obtain record of existing backflow prevention installed. At the effective date of the CCC Program, the City or their Agent will send the Initial Survey to all existing non-residential premises. Once completed, residential premises will be contacted. 2) If it is determined by the City or their Agent that a site visit is required as a follow-up to the Initial Survey, the Property Owner will be contacted to schedule the site survey. 3) If it is determined that backflow prevention needs to be installed, altered, replaced, relocated, or repaired, the Property Owner shall have forty-five (45) days from receipt of the first notification letter from the City to perform the required work. 4) All work required by the City or their Agent, including but not limited to installation, alteration, replacement, relocation, or repair of backflow prevention shall be completed under an approved City of Milford permit through the offices of the Department of Planning. 4.3 Site Survey 1) After the Initial Survey, Site Surveys will be conducted at certain times, as outlined below, on the Property Owner's premises. Survey scheduling and completion shall be the responsibility of the Property Owner. The City or their Agent will contact the Property Owner, when necessary, to provide notification that a survey is required. Site Surveys will be completed at the following intervals, when applicable: • Backflow Prevention Assembly Testing Site surveys shall be conducted by a certified Tester/Surveyor during the testing of a backflow prevention assembly, which occurs upon installation, repair, relocation, after a reported backflow incident, on an annual basis. • Substantial Change to Premises Site Surveys shall be conducted if there is a substantial change to the premises. This includes, but is not limited to, change in premises plumbing, addition of a water service line(s), addition of fire suppression, or any other substantial additions or modifications to the premises which may affect the City of Milford public water system. • Reassessment Existing service line connections shall be reassessed/surveyed at an interval of no more than every ten (10) years to determine if the existing backflow prevention is appropriate for the level of hazard, or if service line backflow protection is required. 2) Internal Plumbing System Survey • The facilities internal water use practices shall be reviewed by a certified Surveyor during the Site Survey to determine whether there are actual or potential cross-connections to the plumbing system through which contaminants or pollutants could backflow into the public water system and/or the facility's internal plumbing system. • Recommendations for internal plumbing cross-connection control and backflow prevention will be provided to the Property Owner upon survey completion. 3) Surveyors Surveyors having proper identification and having given notice shall be permitted to enter the building/premises at any reasonable time for the purpose of survey for the presence or absence of cross-connections, testing, repair, and maintenance of any part of the plumbing system related to any cross-connection control device connected to the City of Milford public water system. A Surveyor having both the required experience component and certification/training component shall be contacted by the Property Owner to conduct on-site surveys in accordance with this CCC Program. • Surveyor Experience Acceptable experience must include one (1) or more of the following: a. Be employed or have been employed by a Water Utility, Water Purveyor, Building Department, Code Enforcement Department OR Regional or Local Water Authority for a period of not less than three (3) years, not more than five (5) years ago; or, b. Held the position of Cross-Connection Surveyor, or similar position, with a municipal body or branch of the military for a period of not less than three (3) years, not more than five (5) years ago; or, c. Have one (1) year or more full-time experience in conducting cross-connection control surveys in non-residential and/or residential facilities for a private, non-governmental, entity. • Surveyor Certification/Training Acceptable certification/training shall include successful completion of the American Society of Sanitary Engineers Standard 5120 - relating to Cross-Connection Control Surveyors and a current, valid certification of completion. (All Surveyors must complete a recertification exam at an interval not to exceed once every three (3) years.) a. Fire suppression backflow preventers shall be inspected by a licensed public fire protection company approved and listed on the State of Delaware office of the State Fire Marshal's most recent listing. 4) Survey Forms A Survey Form shall be used in every required survey and will be filed in a location as directed by the City. This form will be used to record the level of hazard existing at the premises, any existing backflow prevention discovered at the premises and any additional backflow prevention required or recommended to be installed at the premises at the time of the survey. 5) Survey Procedure Completed CCC surveys shall include the following information: • Identify the premises to be surveyed and date of survey. • The building or facility contact/Property Owner, or their designated representative. • Notation that the building or facility contact/Property Owner or their designated representative was explained the purposes of the CCC Program. • Survey/Evaluate the level of hazard present within the premises and the status of cross-connection control and backflow prevention containment protection on the premises. • Survey the premises and record the following information: a) Any identified deficiency in the exposed piping and water outlets/uses downstream of the service connection(s) b) All existing backflow prevention assemblies, devices, and methods (including make, model #, size, serial # if applicable) that are currently in place on the premises c) Any point of use or equipment supplied for each backflow prevention assembly, device, or method • Any required or recommended backflow prevention assemblies required to be installed at the premises for corrective action or containment or isolation protection. • A piping diagram or schematic of the plumbing system may be requested or required. 4.4 Record Keeping and Data Management The City or their Agent has the right to request specific CCC and backflow prevention related information, including but not limited to, containment or service line protection methods, backflow assembly installation, repair, relocation, and test records, CCC Program compliance information, and piping diagrams for the premises. All data, reports, test results, surveys and any other related information obtained by the City, or their Agent from the Property Owner will be entered into a data management system and held for a period of no less than ten (10) years, per the CCC Code. This information will include: • Address and location • The building or facility contact/Property Owner, or their designated representative and their contact information. • Survey information • Premises type/use • Level of hazard classification • Backflow prevention assemblies present at the premises • Location of any assemblies • Make, model, and size of assemblies • Testing and maintenance records for the assemblies • Description of other cross-connections within the building or facility - Air gaps - Non-testable devices - Methods

[Ord. No. 2023-18, § 7, 5-22-2023]

Ask a question about Milford law

Corpus searches the Milford sections it holds and shows the ones that match, with their citations. Free, no sign-in.