Sec. 19-113. - Minimum plan review criteria for buildings.
The examination of the documents by the building official shall include the following minimum criteria and documents: a floor plan, site plan, foundation plan, floor/roof framing plan or truss layout, all fenestration penetrations, flashing, and rough opening dimensions, and all exterior elevations, as more specifically described as follows, when applicable. (1) Commercial buildings. (a) Building. 1. Site requirements shall include: a. Parking; b. Fire access; c. Vehicle loading; d. Driving/turning radius; e. Fire hydrant/water supply/post indicator valve (PIV); f. Setback and separation (to assumed property lines and each other); g. Location of specific tanks, water lines and sewer lines; and h. Flood hazard areas, flood zones, and design flood elevations. 2. Occupancy group and special occupancy requirements. 3. Minimum type of construction shall be determined (see Table 503, Florida Building Code). 4. Fire-resistant construction requirements shall include the following components: a. Fire-resistant separations; b. Fire-resistant protection for type of construction; c. Protection of openings and penetrations of rated walls; and d. Fire blocking and draft stopping and calculated fire resistance. 5. Fire suppression systems shall include: a. Early warning smoke evacuation systems; b. Schematic fire sprinklers; c. Standpipes; d. Pre-engineered systems; and e. Riser diagram. 6. Life safety systems shall be determined and shall include the following requirements: a. Occupant load and egress capacities; b. Early warning; c. Smoke control; d. Stair pressurization; and e. Systems schematic. 7. Occupancy load/egress requirements shall include: a. Occupancy load; b. Gross area; c. Net area; d. Means of egress; e. Exit access; f. Exit; g. Exit discharge; h. Stairs construction/geometry and protection; i. Doors; j. Emergency lighting and exit signs; k. Specific occupancy requirements; l. Construction requirements; and m. Horizontal exits/exit passageways. 8. Structural requirements shall include: a. Soil conditions/analysis; b. Termite protection; c. Design loads; d. Wind requirements; e. Building envelope; f. Impact resistant coverings or systems; g. Structural calculations (if required); h. Foundation; i. Flood requirements in accordance with Section 1612, Florida Building Code, including lowest floor elevations, enclosures, flood damage-resistant materials, and floor elevation as shown in Table I at the end of this section; j. Wall systems; k. Floor systems; l. Roof systems; m. Threshold inspection plan; and n. Stair systems. 9. Materials shall be reviewed and shall at a minimum include the following: a. Wood; b. Steel; c. Aluminum; d. Concrete; e. Plastic; f. Glass; g. Masonry; h. Gypsum board and plaster; i. Insulating (mechanical); j. Roofing; k. Insulation; and l. Building envelope portions of the Florida Building Code, Energy Conservation (including calculation and mandatory requirements). 10. Accessibility requirements shall include the following: a. Site requirements; b. Accessible route; c. Vertical accessibility; d. Toilet and bathing facilities; e. Drinking fountains; f. Equipment; g. Special occupancy requirements; and h. Fair housing requirements. 11. Interior requirements shall include the following: a. Interior finishes (flame spread/smoke development); b. Light and ventilation; c. Sanitation; and d. Building envelope portions of the Florida Building Code, Energy Conservation (including calculation and mandatory requirements). 12. Special systems: a. Elevators; b. Escalators; and c. Lifts. 13. Swimming pools: a. Barrier requirements; b. Spas; and c. Wading pools. (b) Electrical. 1. Electrical shall include: a. Wiring; b. Services; c. Feeders and branch circuits; d. Overcurrent protection; e. Grounding; f. Wiring methods and materials; g. Ground fault circuit interrupters; and h. Building envelope portions of the Florida Building Code, Energy Conservation (including calculation and mandatory requirements). 2. Equipment. 3. Special occupancies. 4. Emergency systems. 5. Communication systems. 6. Low voltage. 7. Load calculations. 8. Design flood elevation. (c) Plumbing. 1. Minimum plumbing facilities. 2. Fixture requirements. 3. Water supply piping. 4. Sanitary drainage. 5. Water heaters. 6. Vents. 7. Roof drainage. 8. Back flow prevention. 9. Irrigation. 10. Location of water supply line. 11. Grease traps. 12. Environmental requirements. 13. Plumbing riser. 14. Design flood elevation. 15. Building envelope portions of the Florida Building Code, Energy Conservation (including calculation and mandatory requirements). (d) Mechanical. 1. Exhaust systems shall include: a. Clothes dryer exhaust; b. Kitchen equipment exhaust; and c. Specialty exhaust systems. 2. Equipment. 3. Equipment location. 4. Make-up air. 5. Roof-mounted equipment. 6. Duct systems. 7. Ventilation. 8. Combustion air. 9. Chimneys, fireplaces and vents. 10. Appliances. 11. Boilers. 12. Refrigeration. 13. Bathroom ventilation. 14. Laboratory. 15. Design flood elevation. (e) Gas. 1. Gas piping. 2. Venting. 3. Combustion air. 4. Chimneys and vents. 5. Appliances. 6. Type of gas. 7. Fireplaces. 8. LP tank location. 9. Riser diagram/shutoffs. 10. Design flood elevation. (f) Energy calculations. (g) Demolition. 1. Asbestos removal. (2) Residential (1- and 2-family). (a) Building. 1. Site requirements shall include: a. Setback and separation (to assumed property lines and each other); b. Location of septic tanks; c. Drainage plan; and d. Floor elevation (including for non-special flood hazard areas), which shall comply with or exceed the minimum standards in Table I at the end of this section. 2. Fire-resistant construction (if required). 3. Smoke detector locations and if required, carbon monoxide detector locations. 4. Egress. a. Egress window size and location stairs construction requirements. 5. Structural requirements shall include: a. Wall section from foundation through roof, including assembly and materials connector tables; b. Termite protection; c. Design loads; d. Wind requirements; e. Building envelope; f. Structural calculations (if required); g. Foundation; h. Wall systems; i. Floor systems; and j. Roof systems. 6. Accessibility requirements: show/identify accessible bath. 7. Impact resistant coverings or systems. 8. Flood requirements in accordance with Section 322, Florida Building Code, Residential, including enclosures, flood damage-resistant materials, and floor elevation as shown in Table I at the end of this section. (b) Electrical. 1. Electric service riser with wire sizes, conduit detail and grounding detail; 2. Location of service equipment and any sub-panels with complete load calculations, panel schedules; 3. Power and lighting floor plan showing locations of switches, receptacles, lighting outlets and ceiling fans; 4. Location of generator and transfer switch, if installed. (c) Mechanical. 1. HVAC equipment and location; 2. Duct systems; 3. Clothes dryer and bathroom exhaust; 4. Ventilation and kitchen equipment exhaust, if required. (d) Plumbing. 1. Plumbing riser; 2. Plumbing floor plan showing all fixture and appliance locations; 3. Sanitary drainage system, building sewer and cleanout location; 4. Location of water supply system; 5. Irrigation system and any backflow device, if required. (e) Gas. 1. Gas piping. 2. Venting. 3. Combustion air. 4. Chimneys and vents. 5. Appliances. 6. Type of gas. 7. Fireplaces. 8. LP tank location. 9. Riser diagram/shutoffs. (f) Energy calculations. (g) Swimming pools. 1. Barrier requirements. 2. Spas. 3. Wading pools. 4. Piping configuration. 5. Structural pool shell. 6. Electrical feeder/riser diagram with wire size, conduit detail and equipotential bonding for all pool equipment. 7. Underwater luminaires, audio systems and pool features. (3) Exemptions. (a) Plans examination by the building official shall not be required for the following work being performed pursuant to the Florida Building Code, Building: 1. Replacing existing water heaters. 2. Minor electrical, plumbing and mechanical repairs. 3. Annual maintenance permits. (b) Manufactured buildings or prototype building plans, except that plan review by the building official shall still be required for local site adaptations and foundations of buildings which are constructed on site, and modifications or structures that require waiver, as to the following: 1. Site requirements. a. Setback and separation (as to assumed property lines and to each other). b. Location of septic tanks (if applicable). 2. Structural. a. Wind zone. b. Anchoring. c. Blocking. 3. Plumbing. a. List potable water source and meter size (if applicable). 4. Mechanical. a. Exhaust system. b. Clothes dryer exhaust. c. Kitchen equipment exhaust. 5. Electrical. Electrical service riser diagram with wire sizes, conduit detail, grounding detail and exterior disconnect location. (c) Plans examination by the building official shall not be required for the following work being performed pursuant to the Florida Building Code, Residential: 1. Replacing existing equipment such as air-handling units, condensing units, heat pumps, refrigerant compressor, backflow preventer or plumbing appliance. 2. Minor electrical, plumbing and mechanical repairs. 3. Reroofs or roofing repairs. 4. Replacement of windows and doors, provided no structural changes are made to the exterior wall openings. 5. Installation of impact shutters for windows and doors. Table I. Summary of Flood Zone and Elevation Requirements of Section 19-238 Flood Zone and Elevation Zone A and AE Elevation of the Lowest Floor | Zone AO Elevation of the Lowest Floor | Coastal High Hazard Area (Zone V) and Coastal A Zone Elevation of the Lowest Horizontal Structural Member of the Lowest Floor | Non-SFHA (Shaded and Unshaded X Zone) Elevation of Finished Floor Elevation Residential | BFE + 1.0 ft., DFE, SFWMD FFE, or 1.5 ft. above COR, whichever is highest | Depth number + 1.0 ft., 3 ft. if no depth number, SFWMD FFE, or 1.5 ft. above COR, whichever is highest | BFE + 1.0 ft., DFE, SFWMD FFE, or 1.5 ft. above COR, whichever is highest | SFWMD FFE or 1.5 ft. above COR, whichever is highest Flood Design Class 1 and 2 | BFE + 1.0 ft., DFE, SFWMD FFE, 1.5 ft. above crown of road, whichever is highest | Depth number + 1.0 ft., 3 ft. if no depth number, SFWMD FFE, or 1.5 ft. above COR, whichever is highest | BFE + 1.0 ft., DFE, SFWMD FFE, 1.5 ft. above crown of road, whichever is highest | SFWMD FFE or 1.5 ft. above COR, whichever is highest Flood Design Class 3 | BFE + 1.0 ft., DFE, SFWMD FFE, 1.5 ft. above crown of road, whichever is highest | Depth number + 1.0 ft., 3 ft. if no depth number, SFWMD FFE, or 1.5 ft. above COR, whichever is highest | BFE + 2.0 ft., DFE, SFWMD FFE, 1.5 ft. above crown of road, whichever is highest | SFWMD FFE or 1.5 ft. above COR, whichever is highest Flood Design Class 4 | BFE + 2.0 ft., DFE, SFWMD FFE, 1.5 ft. above crown of road, whichever is highest | Depth number + 2.0 ft., 4 ft. if no depth number, SFWMD FFE, or 1.5 ft. above COR, whichever is highest | BFE + 2.0 ft., DFE, SFWMD FFE, 1.5 ft. above crown of road, whichever is highest | SFWMD FFE or 1.5 ft. above COR, whichever is highest Legend: BFE - Base Flood Elevation as shown on the current effective Flood Insurance Rate Map (FIRM) DFE - Design Flood Elevation (equals BFE on FIRM) SFWMD FFE - South Florida Water Management District permit minimum required finished floor elevation (if applicable) COR - Crown of street or road abutting the site
(Ord. No. 5455, § 2, 5-22-18; Ord. No. 5515, § 1, 1-28-20; Ord. No. 5720, § 2, 12-10-24)
Ask a question about Boca Raton law
Corpus searches the Boca Raton sections it holds and shows the ones that match, with their citations. Free, no sign-in.