Sec. 28-1884. - Design standards.

(1) An EMD shall comply with the following design standards: (a) Location. For commercial or mixed-use buildings, primary façades shall be built to establish a consistent street edge. At least 70 percent of a building's primary façade shall be built in accordance with the minimum and maximum front yards required by this division. The remaining 30 percent may be offset by no more than 15 feet; however, the 15-foot maximum yard shall not apply to pocket parks and public gathering spaces. Existing buildings that do not comply with this requirement shall be supplemented by adding 1 or more new buildings to satisfy this requirement. (b) Placement and orientation of doorways and entrances. A building shall have at least 1 major building entrance facing the primary street frontage and its placement and orientation shall be considered carefully in order to encourage and promote pedestrian walkability and active uses; (c) Massing and articulation. Building façades on primary streets shall provide articulation, changes in materials or height, or other architectural features that interrupt the building plane at least once every 150 linear feet. Additionally, no section of a building's primary frontage may be blank or completely devoid of any architectural features for more than 50 linear feet; (d) The building façade shall include pedestrian-scaled details, articulation and quality craftmanship; (e) Rooflines shall be architecturally compatible with the buildings they serve and shall not exceed 300 linear feet without any variation in pitch, plane, height or roof style; and (f) The EMD master plan/site plan shall maintain the view corridors at entry points on the streets within the development, promoting visibility of architecturally significant iconic buildings, open spaces, plazas and public art features. (g) Pedestrian and bicycle environment. The design of new projects shall promote pedestrian walkability, create a bicycle-friendly environment, and ensure connectivity through design elements including, but not limited to: 1. Providing connectivity for pedestrians and cyclists with external streets and internal streets (if any), pathways, or bike facilities in accordance with an approved pedestrian and bike plan; 2. In addition to internal streets and driveways as noted above, the incorporation of bike paths in other locations is encouraged to connect property amenities, transit and bike stations, as well as to provide connections to residents, employees and guests of the EMD; 3. Bike racks and storage facilities (both secure and unsecure) or bike sharing docks shall be conveniently located throughout the development in order to promote the use of bike paths to access proposed and existing buildings, community amenities and the Yamato Tri-Rail Station; and (h) When both non-residential and residential uses are proposed within a building, the first floor along any street shall include active uses, such as retail or other compatible non-residential uses that are appealing to pedestrians and have well-designed visibility and access to the building from the street. Where a residential building is proposed, any first floor frontage along a street shall include spaces that encourage visual interest for pedestrians, such as leasing offices and recreational amenities for residents. (2) Parking design. All parking, except on-street parking, shall be located behind or to the side of buildings or within parking structures, and shall be designed as follows: (a) For all new development, except for entrances and exits to parking structures, structured parking shall be wrapped with habitable uses or located in such a way that buildings surround the parking structure and substantially screen such parking from a public street. If a parking structure wall does not front a street but is visible from a public street, screening by a method other than building space with habitable uses (such as landscaping or decorative structures) may be permitted, provided such screening complements the building architecture. Provided, however, in no event shall such screening by a method other than building space with habitable uses be used for more than 2 façades of the parking structure. (b) Structured parking shall be screened with architectural elements that enhance the streetscape, such as stoops, balcony overhangs, architectural decorative screening and/or art, except as provided in this section. (c) Landscaping plans shall include trees, shrubs, or groundcover to adequately screen surface parking lots. (3) Sustainability and green building design. (a) Project design and materials to achieve sustainability and green building design shall be incorporated into any new development. (b) Buildings in an EMD shall be designed to prioritize energy efficiency, water conservation, durability, and use of nontoxic materials, including the incorporation of recycled materials ...... (c) While all new buildings are encouraged to be designed and constructed according to LEED Certified standards, the Florida Green Building Code, or equivalent, LEED Certification or Florida Green Building Code certification is not required. (4) Compatibility criteria. The design of any EMD shall be compatible with adjacent properties. Compatibility is achieved when the apparent scale and massing of new buildings aligns with the goal of achieving a mix of uses resulting in a more sustainable mobility-oriented neighborhood. The design should establish connections between buildings and create a unified pattern when viewed from a visual perspective. The determination of compatibility between the EMD and adjacent properties shall take into consideration various factors, including, but not limited to, the following: the location, scale, massing, and design of buildings and other improvements; a street grid pattern that encourages and promotes connectivity between uses, parking, open spaces and roadways; a pattern of bicycle and pedestrian pathways that encourage their use; variation in roof lines and building projections; the blending of sizes, proportions, and orientations of windows, doors, balconies, and terrace areas to create visual interest in design; the location and treatment of entryways; the use of decorative features and architectural styles that blend and integrate the different building types and uses; and the use of landscaping that minimizes massing, beautifies the streetscape, and promotes walkability. (5) Contextual criteria. (a) As used in this section, "context" refers to the relationship between the site's development and adjacent street types, surrounding land uses, and on-site or nearby natural features, such as parks, plazas, open spaces or landscaping. Effective transitions to these adjacent uses and features should take into account and satisfy comprehensive plan policies. The term "context" should not be construed as a desire to replicate existing surroundings but rather to provide appropriate transitions to those surroundings. Additionally, "context" is not limited to architectural style or design, although in some instances, relationships may be reinforced by an architectural response. (b) Context-based design standards. In addition to the architectural review required pursuant to section 2-129, the following context-based design standards are applicable within an EMD, as further illustrated on the accompanying diagrams. In the event there is a conflict between this section and sections 2-129 and 2-130, this section shall control: 1. Color and texture. a. Accent colors shall be selected to complement the dominant building color and may be applied to window mullions, cornices and other architectural elements. b. Fluorescent colors shall not be used. c. If visible from an adjacent right-of-way, the design of the roof shall be complimentary to the overall design of the building. 2. Building materials. a. Building façades may include elements such as pilasters, cornices, string courses, window sills, lintels, and rustication to add detail. Brick, cast stone, stone, ornamental metal, EIFS, stucco and concrete may be used for such elements. b. The transition from outdoor to indoor spaces should be clearly indicated. Materials used in a lobby should be distinct from those applied to the exterior walls. c. On all frontages, walls shall display an articulated base course. d. Walls shall show no more than 3 materials or colors. e. Walls shall be finished in brick, stone, cast stone, or stucco products. f. Any visible wood or simulated wood shall be painted. g. Brick mortar joints shall be struck. h. Aluminum siding or cladding, galvanized steel or other bright metal (except when used as a roof) or simulated stucco products shall be prohibited. Provided, however, this prohibition shall not apply to energy-efficient EIF (exterior insulation finish system) stimulated stucco. 3. Attachments. a. Porches and loggias shall have finishes of brick, case stone, EIFS, stucco, or cast material. b. Awnings shall be a metal armature with a canvas membrane. c. Gutters, downspouts, and projecting drain pipes shall be made of galvanized metal. d. Arches and piers shall be no less than 1 by 1 foot. e. Wood and metal posts for porches or loggias shall be no less than 6 inches by 6 inches. f. Railings and protecting walls that are attached to buildings shall be designed as architectural extensions of the building, constructed with the same materials and in the same style. g. Balconies that are cantilevered shall be visibly supported by brackets. 4. Roofs. a. Flat or gabled (sloped) roofs are permitted. b. If principal roofs are sloped, such roofs shall be designed as a symmetrical gable or hip roof, with an angle between 3:12 and 8:12. If the roof is flat roofs, it shall be surrounded by a horizontal parapet wall that is no less than 3.5 feet in height. c. The eaves of the building shall be continuous, except where they meet a major building articulation. The eaves shall project no less than 4 feet from the building and have an elaborated soffit. d. All roof penetrations, including vent stacks, shall be located on the back slope of the principal frontage of the roof. In all cases, such stacks and other penetrations shall be finished to match the color of the roof. e. Parapets shall be designed to screen rooftop mechanical equipment from public view at ground level. f. Skylights shall be installed generally parallel to the plane of the roof or ceiling on which they are installed. 5. Openings. a. Windows shall be single, double or triple-hung, or operable casements. Windows shall be vertical or square in proportion. Windows shall have a 3-inch minimum reveal and shall not be flush mounted. b. Residential screens shall cover the entire window area. c. Inoperable shutters are not allowed. Operable shutters shall be sized and shaped to match the associated openings. d. Doors on balconies shall be French doors. e. Upper story openings shall be centered above lower story openings. Openings on gabled ends must be centered. f. Storefront windows shall be a maximum of 2.5 feet above ground level. g. Window frames shall be made of non-reflective glass and painted aluminum, wood or vinyl h. Shutters shall be either louvered or paneled, and made of painted wood, metal, or Hardie plank or its equal. (6) Screening and service areas. (a) Loading areas and services bays. Service areas shall be screened from adjacent property, and from all public rights-of-way. Service areas should ideally be located at the rear (side opposite the street) of all buildings. Where it is necessary to locate service areas on the side of buildings perpendicular to the street, measures shall be taken to screen any view into the service area from motorists and pedestrians passing by on the street. Preferred methods of screening include walled entrances, landscaping, and depressed service areas. A shorter wall constructed of the same materials as the main building may serve as an extension of the building. (b) Street level mechanical equipment. All ground-mounted service equipment, including HVAC, utility meters, transformers, irrigation equipment, satellite dishes, and any other ground mounted equipment, etc. shall be screened from the sidewalk. (c) Roof mounted mechanical equipment. 1. All roof mounted mechanical elements must be screened from view from the adjacent public right-of-way. Where applicable, screening shall be accomplished in a manner which is architecturally compatible with the building design. 2. When roof decks with mechanical units are visible from adjacent developments, such decks shall be screened and painted to match finish roof material and minimized to reduce their direct view. 3. Roof mounted mechanical units and penthouses shall be as symmetrically placed as possible on the roof deck.

(Ord. No. 5655, § 7, 10-11-23)

Ask a question about Boca Raton law

Corpus searches the Boca Raton sections it holds and shows the ones that match, with their citations. Free, no sign-in.