C-407 — Urban residential 1 frontage
Code of Ordinances of the City of Clearwater, Florida (Supp. No. 90: codified through Ordinance No. 9859-26, enacted January 15, 2026) · Clearwater Community Development Code § C-407
Corpus is an independent public-information project, not the official City of Clearwater website. Stable reference: corpuslaw.us/code/d8231b33-e086-40e4-9832-fadce2753d51
Section C-407. - Urban residential 1 frontage.
[image omitted; see the official code] Figure 18. Urban Residential 1 Example [image omitted; see the official code] Figure 19. Urban Residential 1 Building Placement [image omitted; see the official code] Figure 20. Urban Residential 1 Parking & Projections A. General. The Urban Residential 1 Frontage Standards are intended for application along Street Types B and C which are identified as appropriate for high levels of existing or planned pedestrian activity. Development standards for this frontage require buildings aligned along adjacent streets, oriented to public sidewalks with residential ground floor uses with minimal front setbacks, ground floors elevated above adjacent sidewalk grade, and parking to the rear of occupied building space. (In the sections below, the bold lettering in parentheses refers to the annotations in Figures 19 and 20.) B. Building Setbacks. 1. Buildings shall be placed along street frontages consistent with the following building setbacks from property lines: a. Front Setbacks (A): 3 feet minimum, 5 feet maximum. b. Side Setbacks (B): 0 feet maximum, or as required by applicable building and fire codes. c. Rear Setbacks (C): 10 feet minimum. 2. Front building setbacks on Fort Harrison Avenue, Cleveland Street, and Osceola Avenue shall be increased to the extent required to allow for the creation of sidewalks widths consistent with the Master Streetscape Plan within the Clearwater Downtown Redevelopment Plan. 3. To promote continuity of frontages along front setbacks, the space between buildings on the same or adjacent sites, or between building wings for "U"-shaped buildings, shall be 20 feet maximum and may be occupied by a mid-block pedestrian passageway open for tenant use. Where such space is provided with no pedestrian passageway or to provide for a private courtyard, a 6-foot minimum, or 8-foot maximum high brick or other masonry wall, wall with masonry columns linked by substantial grill work, or wall designed to match the architectural design of the building shall be constructed in line with the front building façade. C. Front Setback Improvements. 1. The front setback area shall be improved with landscape areas and walkways providing access to common building entries and to porches or stoops at entries to ground floor units. Walkways to building entries shall generally match sidewalk grade. 2. Landscaping in the front setback area shall comply with landscape requirements in Section 3-1202. 3. Walls, railings, fencing, or other similar improvements not part of a porch or stoop are prohibited within front setbacks. 4. Fenced, walled, or otherwise enclosed patios or other forms of enclosed outdoor space are not permitted for ground floor units along street frontage. D. Ground Floor Façades and Entries. 1. Building façades along street frontages shall meet building design standards in Appendix C, Division 6. 2. Ground floor front building façades shall meet the following standards (D): a. Building façades shall be located along front setbacks and aligned generally parallel to the primary street frontage property line. b. The finished floor elevation of ground floor residential units along front setbacks shall be elevated 18 inches minimum, 36 inches maximum above the grade of adjacent sidewalks. c. Primary entries to individual ground floor units and shared lobby space providing access to upper story units shall be located along the front façade and be visible from streets and sidewalks. 3. Stoops shall be provided at entries to individual ground floor units and be designed to meet the following standards (E): a. Stoops may project 5 feet maximum from front building façades into setbacks. b. Stoops shall include stairs and landings providing access to unit entries with low walls or railings on stairs and landings as required by Florida Building Code. c. No more than two front stoops serving adjacent units shall be connected. d. Landscape areas between stoops may be defined by curbing or low walls. Such landscaping shall comply with landscape requirements in Section 3-1202. 4. Canopies or other forms of weather protection shall be provided at front building entries to shared ground floor lobby space and shall meet the standards in Appendix C, Division 6 (E). E. Parking. 1. In addition to the following standards, parking location, design and access shall meet standards in Appendix C, Division 5. 2. Parking shall be located to the rear of the property away from the primary street frontage and corner locations. Parking to the side of buildings is prohibited. 3. Parking, vehicular loading/unloading areas, and passenger drop off areas are prohibited in front setbacks. 4. Parking and vehicular circulation areas incorporated in the ground floor of a building along street frontages shall be located behind fully-enclosed, occupied building space with a depth of 20 feet minimum (F). 5. Surface and structured parking shall comply with side and rear building setbacks. Side and/or rear setbacks shall not apply between surface parking areas on abutting properties which provide for shared access and use. 6. With approval from appropriate City, County or State authorities, parallel parking may be constructed within the right-of-way along streets abutting the property.
(Ord. No. 9149-18, § 8, 8-2-18; Ord. No. 9643-23, § 29, 4-4-23)
Ask a question about Clearwater law
Corpus searches the Clearwater sections it holds and shows the ones that match, with their citations. Free, no sign-in.
