C-408 — Urban residential 2 frontage
Code of Ordinances of the City of Clearwater, Florida (Supp. No. 90: codified through Ordinance No. 9859-26, enacted January 15, 2026) · Clearwater Community Development Code § C-408
Corpus is an independent public-information project, not the official City of Clearwater website. Stable reference: corpuslaw.us/code/8edf5420-9252-4ad4-9422-4e5b377bf81b
Section C-408. - Urban residential 2 frontage.
[image omitted; see the official code] Figure 21. Urban Residential 2 Example [image omitted; see the official code] Figure 22. Urban Residential 2 Building Placement [image omitted; see the official code] Figure 23. Urban Residential 2 Parking & Projections A. General. The Urban Residential 2 Frontage Standards are intended for application along Street Type D which is identified as appropriate for a mix of land uses and building types. Development standards for this frontage require buildings aligned along adjacent streets, oriented to public sidewalks with residential ground floor uses with modest front setbacks, ground floors elevated above adjacent sidewalk grade, and parking to the rear of occupied building space. (In the sections below, the bold lettering in parentheses refers to the annotations in Figures 22 and 23.) B. Building Setbacks. 1. Buildings shall be placed along street frontages consistent with the following building setbacks from property lines: a. Front Setbacks (A): 8 feet minimum, 15 feet maximum. b. Side Setbacks (B): 5 feet minimum or as required by applicable building and fire codes. c. Rear Setbacks (C): 10 feet minimum. 2. Front building setbacks on Fort Harrison Avenue, Cleveland Street, and Osceola Avenue shall be increased to the extent required to allow for the creation of sidewalks widths consistent with the Master Streetscape Plan within the Clearwater Downtown Redevelopment Plan. 3. To promote the continuity of frontages along front setbacks, the space between buildings on the same or adjacent sites, or between building wings for "U"-shaped buildings, shall be 80 feet maximum. C. Front Setback Improvements. 1. The front setback area shall be improved with landscape areas and walkways providing access to common building entries and to porches or stoops at entries to ground floor units. Walkways to building entries shall generally match sidewalk grade. 2. Landscaping in the front setback area shall comply with landscape requirements in Section 3-1202. 3. Walls, railings, fencing, or other similar improvements not part of a porch or stoop are prohibited within front setbacks. D. Ground Floor Façades and Entries. 1. Building façades along street frontages shall meet building design standards in Appendix C, Division 6. 2. Ground floor front building façades shall meet the following standards (D): a. Building façades shall be located along front setbacks and aligned generally parallel to the primary street frontage property line. b. The finished floor elevation of ground floor residential units along front setbacks shall be elevated 18 inches minimum, 36 inches maximum above the grade of adjacent sidewalks. c. Primary entries to individual ground floor units, where provided, and shared lobby space shall be located along the front façade and be visible from streets and sidewalks. 3. Where primary entries to individual ground floor units are located along the front façade, front porches or stoops shall be provided at entries and designed to meet the following standards (E): a. Porches and stoops may project 4 feet minimum, 8 feet maximum from front building façades into setbacks but shall be located no closer than 2 feet from public sidewalks. b. No more than two front porches or stoops serving adjacent units shall be connected. c. Landscape areas at least 8 feet in width as measured along the front building façade shall be provided between individual or connected porches or stoops. 4. Canopies or other forms of weather protection shall be provided at front building entries to shared ground floor lobby space and shall meet the standards in Appendix C, Division 6 (E). E. Parking. 1. In addition to the following standards, parking location, design and access shall meet standards in Division 5. 2. Parking, vehicular loading/unloading areas, and passenger drop off areas are prohibited in front setbacks. 3. Surface parking located to the side of buildings along streets shall be no greater than 1 bay in width or 60 feet maximum as measured along the street frontage and shall be set back 5 feet behind front building façades and screened from public sidewalks by an opaque hedge or wall 24 to 36 inches in height (F). Side surface parking shall be located along a single building side. 4. Parking and vehicular circulation areas incorporated in the ground floor of a building along street frontages shall be located behind fully-enclosed, occupied building space with a depth of 20 feet minimum (G). 5. Surface and structured parking shall comply with side and rear building setbacks. Side and/or rear setbacks shall not apply between surface parking areas on abutting properties which provide for shared access and use. 6. With approval from appropriate City, County or State authorities, parallel parking may be constructed within the right-of-way along streets abutting the property.
(Ord. No. 9149-18, § 8, 8-2-18; Ord. No. 9643-23, § 29, 4-4-23; Ord. No. 9664-23, § 3, 5-4-23)
Ask a question about Clearwater law
Corpus searches the Clearwater sections it holds and shows the ones that match, with their citations. Free, no sign-in.
