§ 13-141 — Levels of service
Code of Ordinances of the City of Coconut Creek, Florida (Codified through Ordinance No. 2026-016, enacted June 25, 2026. (Supp. No. 6)) · Coconut Creek Code of Ordinances § 13-141
Corpus is an independent public-information project, not the official City of Coconut Creek website. Stable reference: corpuslaw.us/code/61c3d788-2469-40fc-aeb7-54087ff86891
Sec. 13-141. - Levels of service.
(a) Potable water. New development shall not be approved unless there is sufficient available design capacity to sustain the following levels of service for potable water as established in the potable water sub-element of the city comprehensive plan: (1) Minimum design flow: a. Residential: 1. Planning purposes: 100 pgd/capita 2. At site plan* b. Commercial/office: 1. Planning purposes: 3,000 gpad 2. At site plan* c. Industrial: 1. Planning purposes: 2,000 gpad 2. At site plan* d. Other nonresidential: 1. Planning purposes: 162 gpad 2. At site plan* * Specific design estimates of minimum design flow shall be prepared using established standards at time of site plan or determination of specific use. (b) Wastewater. New development shall not be approved unless there is sufficient available design capacity to sustain the following levels of service for wastewater treatment as established in the Sanitary Sewer Sub-Element of the city comprehensive plan: LOS Type of Use | Average Flow | Peak Flow (1) Minimum design flow: a. Residential: 1. Planning purposes | 90 gpd/capita | 180 gpd/capita 2. At site plan | * | * b. Commercial/office: 1. Planning purposes | 2,700 gpad | 5,400 gpad 2. At site plan | * | * c. Industrial: 1. Planning purposes | 1,800 gpad | 3,600 gpad 2. At site plan | * | * d. Other nonresidential: 1. Planning purposes | 147 gpad | 294 gpad 2. At site plan | * | * * Specific design estimates of minimum design flow shall be prepared using established standards at time of site plan or determination of specific use. (c) Transportation system. (1) Levels of service. New development shall not be approved unless there is sufficient available design capacity to sustain the following levels of service for transportation systems as established in the transportation circulation element of the city/county comprehensive plan: Type of facility | Peak Hour Level of Service Arterials | D Collectors | D Local Roads | D (2) Determination of project impact. The impact of proposed development activity on available design capacity shall be determined as follows: a. The area of impact of the development (a traffic shed) shall be determined. The limits of the effected traffic shed area shall be determined in accordance with Broward County Land Development Code Trafficways Plan criteria. The traffic shed shall be that area where the primary impact of traffic to and from the site occurs. If the city/county has designated sectors of the county for determining development impacts and planning capital improvements, such sectors or planning areas may be used. If the application is for a building permit for a single-family or duplex development, the impact shall be presumed to be limited to the collector or arterial serving the local street giving access to the lot, or to the collector or arterial giving direct access to the lot. b. The projected level of service for arterials and collectors within the traffic shed shall be calculated based upon estimated trips to be generated by the project, or where applicable, the first phase of the project, and taking into consideration the impact of other approved but not completed developments within the traffic shed. Information on committed development within the traffic shed shall be provided by the city/county. (d) Drainage system. New development shall not be approved unless there is sufficient available design capacity to sustain the following levels of service for the drainage system as established in the drainage sub-element of the city/county comprehensive plan: Type of Uses | LOS All development: Discharge | 25 yr—1 day storm event Private/public road elevation | 5 yr—1 day storm event Floor elevation | 100 yr—3 day storm event (e) Solid waste. New development shall not be approved unless there is sufficient available design capacity to sustain the following levels of service for the solid waste as established in the solid waste sub-element of the city comprehensive plan: Type of Uses | LOS Residential | 8.9 lbs. per capita per day Industrial and commercial: Factory/warehouse | 2 lbs. per 100 sq. ft. per day Office building | 1 lb. per 100 sq. ft. per day Department store | 4 lbs. per 100 sq. ft. per day Supermarket | 9 lbs. per 100 sq. ft. per day Restaurant | 2 lbs. per meal per day Drug store | 5 lbs. per 100 sq. ft. per day Schools: Grade school | 10 lbs. per room and ¼ lbs. per pupil per day High school | 8 lbs. per room and ¼ lbs. per pupil per day Institutions: Hospital | 8 lbs. per bed per day Nurse or intern home | 3 lbs. per person per day Home for aged | 3 lbs. per person per day Rest home | 3 lbs. per person per day (f) Recreation. New development shall not be approved unless there is sufficient available capacity to sustain the following levels of service for the recreational facilities as established in the recreation and open space element of the city comprehensive plan: Type of Facility | Level of Service All facilities including regional, community and neighborhood | 3 acres/1,000 population
(Ord. No. 163-89, § 2, 10-26-89)
Ask a question about Coconut Creek law
Corpus searches the Coconut Creek sections it holds and shows the ones that match, with their citations. Free, no sign-in.
