For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 12-105 — Irrigation

Code of Ordinances of the City of Davie, Florida (Codified through Ordinance No. O2026-016, enacted September 3, 2026 (Supp. No. 76)) · Davie Code of Ordinances § 12-105

Corpus is an independent public-information project, not the official City of Davie website. Stable reference: corpuslaw.us/code/44ce33b0-1e5d-4cf3-8c3b-15c2121e9c85

Sec. 12-105. - Irrigation.

(A) Irrigation Plans. 1. Irrigations plans shall be designed to recognize different irrigation requirements of the landscape described in this division. 2. The irrigation shall show the following: a. Irrigation points of connection and design capacity; b. Water service pressure at irrigation point of connections (POC); c. Water meter size when revising existing irrigation plans or when utilizing reclaimed water; d. Reduced-pressure-principle backflow prevention devises for each irrigation POC on potable water systems. e. Major components of the irrigation system including all pumps, filters, valves, and pipe sizes and lengths; f. Precipitation rate expressed in inches per hours for each valve circuit. The preparer must attach to the project data sheet the calculations for deriving precipitation rates for each irrigation valve circuit. g. Total flow rate (flow velocity not to exceed 5 feet per second) in gallons per minute (gpm) and operating pressure (psi) for each individual overhead and bubbler circuit, and gallons per hour (gph) and operating pressure for low-flow point irrigation circuit. h. Irrigation legend shall have the following elements: i. Separate symbols for all irrigation requirements with different spray patterns and precipitation rates and pressure compensating devices; general description of equipment; manufactures name and model number for all specified equipment; recommended operating pressure per nozzle and bubbler and low-point pressure per nozzle and bubble and low flow emitter; manufactures recommended overhead and bubble irrigation nozzle rating in gallon per minute (gpm) or gallon for hour (gph) for low flow point applications; minimum (no less than 75% of maximum spray radius) and maximum spray radius per nozzle; and manufactures rated precipitation rate per nozzle at specified psi. i. Location of rain shut-off devices or soil moisture sensors. (B) Efficient Design. All irrigation installations after September 7, 2010, shall meet the irrigation standards identified per [Section] 373.228, F.S. These include: 1. Irrigation systems, including the use of micro-irrigation as appropriate, shall be designed to meet the needs of the plants in the landscape. 2. When feasible, irrigation systems shall be designed to separately serve turf and non-turf areas. 3. The irrigation system plans and specifications shall identify the material to be used and the construction methods. 4. The design shall consider soil, slope and other site characteristics in order to minimize water waste, including overspray, the watering of all impervious surfaces and other non-vegetated areas, and off-site runoff. 5. The system shall be designed to minimize free flow conditions in case of damage or other mechanical failure. 6. The system shall be designed to use the lowest quality water feasible. 7. Rain switches or other approved devices, such as soil moisture sensors to prevent unnecessary irrigation, shall be incorporated. (Section 373.62, F.S.) 9. A recommended seasonal operating schedule and average precipitation rate for each irrigation zone for both establishment and maintenance conditions shall be provided. 10. Control systems shall provide the following minimum capabilities: i. Ability to be programmed in minutes, by day of week, season, time of day, ii. Ability to accommodate multiple start times and programs, iii. Automatic shut off after adequate rainfall, iv. Ability to maintain time during power outages for a minimum of three (3) days, and v. Operational flexibility to meet applicable year round water conservation requirements and temporary water shortage restrictions. 11. Recommended maintenance activities and schedules shall be included. 12. Precipitation rates for sprinklers and all other emitters in the same zone shall be matched, except that microirrigation emitters may be specified to meet the requirements of individual plants. 13. Irrigation systems shall be designed to maximize uniformity, considering factors such as: i. Emitter types. ii. Head spacing. iii. Sprinkler pattern. iv. Water pressure at the emitter. 14. Irrigation systems with main lines larger than two (2) inches or designed to supply more than seventy (70) gallons per minute shall incorporate a means to measure irrigation water use, at a minimum of ninety-five (95) percent accuracy across the flow range. 15. Irrigation system plans and specifications shall require the system installer to conduct final testing and adjustments to achieve design specifications prior to completion of the system and acceptance by the owner or owner's representative. 16. The irrigation system shall be designed to correlate to the organization plants into zones as described in section 12-102 above. The water use zones shall be shown in the irrigation plan. All plants (including turf) require watering during establishment. Temporary facilities may be installed to facilitate establishment. 17. Rain shut-off switch equipment shall be required on automatic irrigation systems to avoid irrigation during periods of sufficient soil moisture, in accordance with Florida Law ([Section] 373.62, F.S.). Said equipment shall consist of an automatic mechanical or electronic sensing device or switch that will override the irrigation cycle of the sprinkler system when adequate rainfall has occurred. 18. The installation of tracer wire along main lines and laterals shall be required to permit easy location and prevent inadvertent cutting of pipes. 19. If the water supply for the irrigation system is from a well, a constant pressure flow control device or pressure tank with adequate capacity shall be required to minimum pump "cycling". 20. Check valves must be installed at irrigation heads as needed to prevent low head drainage and puddling. 21. Nozzle precipitation rates for all heads within each valve circuit must be matched to within twenty (20) percent of one another. 22. No water spray from irrigation systems shall be applied under roof overhangs. 23. Irrigated areas shall not be less than four (4) feet wide, except when next to contiguous property or using micro or drip irrigation. 24. A pressure-regulating valve shall be installed and maintained if static service pressure exceeds eighty (80) pounds per square inch. The pressure regulating valve shall be located between the meter and the first point of division in the pipe and set at a not more than fifty (50) pounds per square inch when measured at the most elevated fixture in the structure served. This requirement may be waived if satisfactory evidence is provided that high pressure is necessary in the design and that no water will be wasted as a result of high-pressure operation. (C) To assist the end user to operate the system property, in addition to the minimum requirements of [Section] 373.228, F.S., the following shall be provided to the owner at the time of installation. The map shall be attached inside each irrigation controller or be kept in another readily available location if it is not practical to insert into a small container. 1. Irrigation schedule information, with instructions for seasonal timer and sensor changes; 2. Irrigation system plans and specifications including as-constructed drawings, recommended maintenance activities and schedules; 3. Operations schedules, design precipitation rates, and instructions on adjusting the systems to apply less water after the landscape is established; 4. Maintenance schedule, water source, water shut-off method, and the manufacturing operational guide for their irrigation controller; 5. To the extent feasible, similar information should be made available for subsequent property transfers. (D) Reduced-pressure-principle backflow preventers shall be recertified yearly.

(Ord. No. 2010-020, § 2(Exh. A), 9-7-10; Ord. No. 2016-014, § 2(Exh. A), 7-27-16)

Ask a question about Davie law

Corpus searches the Davie sections it holds and shows the ones that match, with their citations. Free, no sign-in.