Sec. 12-438.14. - Massing and articulation.

(A) Intent. Massing refers to the bulk plane of a building. The perception of building mass is influenced by the building's distance from the street, its height relative to its width, whether height is reached in one (1) or multiple vertical and/or horizontal planes, and the spacing between buildings. Articulation refers to the treatment of a building's facade. A blank facade has no articulation. A facade with substantial fenestration, balconies, character lines, columns, etc. is highly articulated. Buildings are the face of the town. Their form, quality, interest, function, and style all serve to define the character of this place. (B) Principles. (1) Buildings are encouraged to vary in overall height and not be contained in a single volume of continuous height. (a) All buildings that front Transit-Oriented streets and other collector and arterial streets are encouraged to display a uniform cornice height between twenty-five (25) and thirty-five (35) feet above finished grade. This cornice height should consist of a uniform alteration to the building massing for a minimum of four (4) feet perpendicular to the vertical surface. Buildings exceeding thirty-five (35) feet in height should maintain no more than three (3) stories without horizontal moderation in vertical surface plane. This moderation should consist of a minimum four (4) foot horizontal variation in surface plane such as brise soleil, balconies, building projections, etc. Repetitive moderations are discouraged. (b) The first thirty-five (35) feet of the exterior facade vertical plane should enhance the pedestrian environment by incorporating appropriate architectural features. Such features include cornice, molding stringcourses, ornamentations, changes in material or color, and other sculpting of the architectural surface, which add special interest and are compatible with public sector site elements. (2) Pedestrian bridges extending over public right-of-way may be permitted providing those connections have secured legitimate air rights over the public corridor and meet all applicable codes. The location of pedestrian bridges should be limited to building complexes where buildings share common needs/uses or when the interaction between users of the buildings is important for the success of the use. A connection over SR 84 to future east-west rapid transit is considered a necessity once the transit infrastructure is in place. All over street connections should be of exceptional design, which enhance the visual and functional quality of the streetscape and should be compatible with site elements. (3) Where possible, rooftops should be designed to accommodate various forms of human activity such as sun decks, tennis courts, gardens, outdoor cafes, etc. Roof surfaces not allocated to human activity should be finished with a surface material that does not affect the quality of views from surrounding buildings or site lines from taller buildings should be directed way from unsightly rooftops. All rooftop mechanical equipment, stair, and elevator towers should be designed as an integral part of the building volume and/or adequately screened. Rooftops designed and used to hold topsoil and landscape plantings (green roofs) are encouraged. See also section 12-438.26, "Green building." (4) Facades of buildings should be divided into individual storefronts or entries. (5) Large expanses of glass should be subdivided into smaller units. (6) Differentiation should be provided at the base and the top of windows (see Figure 514-1 for illustrations of this concept). [image omitted; see the official code] Figure 514-1 (7) The ground-level floors should be visually separated from floors above through the use of architectural elements that could include galleries, awnings, canopies or lintels, or by recessing the ground-floor level from the floor above (arcade frontages). (8) A visible and delineated roofline is encouraged, such as a cornice, pediment, or related visual trim. The upper termination of a building should be more strongly developed in a building with a flat or slightly sloping roof (see Figure 12-514-1 for illustrations of this concept). (9) Store entrances should be recessed, not flush, with the edge of the building facade, to provide shelter for persons entering and exiting, to articulate the facade, and to provide maximum window display area at the entrance. (10) Landscaping should provide additional texture at street level as well as increase pedestrian awareness of buildings, their entrances and the visual access. Decorative planters are encouraged as well as trees planted utilizing tree grates. (11) Building design should encourage multi-tenant occupancy at the lower two (2) floors. (12) Solid walls should not exceed twenty (20) feet in length without vertical articulation. (13) Ornamental fountains, waterfalls, sculptures, arbors, trellises, planted beds, clock pedestals, awnings, and canopies are encouraged. (14) False fronts or parapets that create an insubstantial appearance should be avoided. (15) Stepping the building (see Figures 12-512-1 and 12-512-2) can also reduce the apparent scale of the building and establish a "base" and a "top." (16) Changes in mass should relate to structural system(s) and the organization of interior space. (17) New development, or the retrofitting of existing development, should address the public sidewalk. Design of the sidewalk-level facade should be incorporated into the design of the overall building. (18) Street frontage facades should have entryways at reasonable intervals, typically no more than fifty (50) feet apart. (19) Ground level facades that face the street should be designed with entrances, windows, display windows, or other display devices. (C) Requirements. This subsection applies to buildings other than industrial buildings within the RAC-RTW and RAC-RTE districts that have no frontage on arterial or collector roads, or that are substantially screened from such roads. (1) Facades shall be constructed in a manner to appear substantial, avoiding low-quality building materials and construction details that contribute to the perception of a facade as flimsy, or are inconsistent with the materials and architectural style. (2) The building facade shall use architectural solutions (e.g. building materials, texture, offset building massing, repetition of columns, recess entries, windows, and awnings) to avoid the creation of impenetrable, un-articulated building facades. (3) Landscape elements shall never impede pedestrian circulation. (4) Single dominant building masses are prohibited. (5) Substantial variations in massing shall include changes in height and horizontal plane. (6) Horizontal mass shall not exceed a height to width ratio of one to three (1:3), without a substantial architectural element that either projects up or away from the building, such as a tower, bay, lattice, or other architectural feature. (7) Building massing, architectural details, entry details or changes in materials shall be used to highlight the location of building entries. For example, greater height can be used to accentuate entries in the form of tower elements, tall voids, or a central mass at an entry plaza. (8) Buildings that are part of an existing or future complex shall have a unity of character and design. The design character of buildings shall be such that it is aesthetically pleasing and without cluttered forms having no apparent system of organization. (9) All building elevations shall receive architectural treatment, although the primary emphasis may be given to the main facade(s). (10) All development must be designed to enhance ground-level architectural elements on a human scale. Entry conditions, building materials, awnings, windows, lighting, and well-designed signage can all contribute to conditions ideal for attracting pedestrians. (11) All buildings shall have a minimum of two (2) planes of vertical separation.

(Ord. of 2-6-08, § 1(Exh. A); Ord. No. 2010-021, § 6, 9-7-10; Ord. No. 2012-28, § 2(Exh. A)(§ 12-32.514), 12-5-12)

Ask a question about Davie law

Corpus searches the Davie sections it holds and shows the ones that match, with their citations. Free, no sign-in.