Sec. 12-438.24. - Building design guidelines.

For areas designated Western Theme Overlay District, this section shall be superseded by the Western Theme Development Manual. (A) Architectural Articulation. Architectural articulation describes the treatment of facades and building massing that ultimately form a significant part of the individual buildings "expression" and by extension the quality of the built environment overall. (1) Principles. (a) Increased articulation at ground level and at levels where people interact directly with the building promotes a more "human scale". (b) Increased articulation at primary facades (those on major thoroughfares) is appropriate to provide a sense of hierarchy in the visual environment. (c) Individual buildings can have varied approaches to architectural articulation with respect to each other but should have a consistent approach within a single building in terms of proportion, limited material mix, etc. (d) Articulation should generally be arranged so to emphasize the vertical over the horizontal in proportion. (B) Architectural Landmarks. Architectural landmarks are significant buildings that help anchor important public spaces. They help create hierarchy within the built environment with respect to the open spaces that they define and create common points of focus and reference within the built environment. (1) Principles. (a) Architectural landmarks should be located in prominent locations and at the end of important vistas as they become reference points and anchors. (b) Architectural landmarks should have a building program that speaks to the community as a whole and is used by the broader public. (c) Architectural landmarks should have programs with frequent use and large numbers of people; they naturally become focuses of energy within a city. (d) Traditionally, architectural landmarks have been city halls, post offices, religious facilities, theaters, and museums. (e) Private buildings can be considered for architectural landmark status based on the nature and quantity of use, a significant campus building for instance would be an appropriate example. (f) An approved landmark building is encouraged to create a unique architectural expression to help it stand out within the built context. (g) The landscape and/or plaza space in front and around an architectural landmark should also be of higher quality, unique and take into consideration the larger space or sequence of spaces that it is anchoring. (h) Architectural landmarks typically are articulated with more monumental or larger scale architectural elements, designed again to give prominence. (i) Architectural landmark buildings are encouraged to be in use for during as many different parts of the day and night as possible, gathering and activity are recommended. (2) Requirements. (a) A building program must be reviewed for confirmation of architectural landmark status by virtue of proposed position in Master Plan, use and quality of proposed building. (b) An approved landmark building should be given special consideration with respect to the zoning requirement that apply to typical buildings. Such allowances would be as follows: 1. Additional height (if warranted, not typical of landmarks) 2. Additional density 3. Reduced setbacks 4. Increased design flexibility (styles and materials that might otherwise be considered based on the quality of design) (C) Fenestration. Fenestration refers to the building openings, windows, etc. that provide natural light to the interior of the built environment and also form a significant part of a buildings architectural expression. The treatment of the fenestration is critical in both defining visually the built form of buildings, managing and providing natural light to the interior of spaces and effecting energy use as a product of heat gain by the sun. (1) Principles. (a) There should be an orderly relationship among windows, doors, porches, and roof forms. (b) Windows and openings should tend to be vertical in proportion. (c) Areas with large glazed surfaces should have additional articulation to both provide sufficient architectural detail to create a "human scale" and to provide shading on the heat gain intensive sides of buildings. (d) Clear glazing with Low E coatings (for heat gain) are strongly preferred to reflective surfaces. The life of the inside of the building should be visible from the exterior wherever possible. (e) Fenestration/louvers at parking structures where exposed to side streets should be proportioned similar to the rest of the structure and be attractively treated. (f) Articulation around windows/openings should be consistent and proportionate to the building expression as a whole so as to integrate the fenestration into the facade as a whole. (2) Requirements. (a) Windows will be required to be vertical in proportion and curtain wall areas will be required to affect a vertical proportion with the hierarchy of their members. (b) Storefronts will require vertical members at no greater than eight (8) feet to zero (0) inch intervals to create sufficient articulation at ground level. (c) Mirrored glazing or very dark shading glazing is prohibited along street frontages other than local street frontages within the RAC-RTW and RAC-RTE districts. (D) Architectural Lighting. The treatment of architectural lighting is an important visual enhancement to the built environment, it also is part of the overall illumination system which relates to safety at night. (1) Principles. (a) Lighting can either be concealed and indirect or can be provided by well designed, quality fixtures that create enhancement to the architecture that they are attached to. (b) Step lights and bollards at a walking level enhance safety and provide attractive lighting that does not create visual glare. (c) Street lighting should be of an attractive and long lasting design that fits well into the overall design context and should have light apertures that focus the lighting on the street and away from buildings so as not to disrupt the residences. (d) Minimum light levels must be met from a safety point of view but excessive lighting and energy waste must also be avoided. (e) Natural light colors are preferred; high pressure sodium (orange) lighting is discouraged. (f) Ballast noise/maintenance is also an important consideration. (2) Requirements. (a) All exterior steps and significant grade transitions must have light levels for safety per accepted industry standards. (b) Exterior exit ways, parking lots and public areas around buildings must have sufficient light levels for safety per accepted industry standards. (c) Lighting designs will be reviewed by the town from the standpoint of energy efficiency, color, quality, and aperture/spread. (d) High pressure sodium lighting will be limited to service areas and areas with limited public impact only. (e) All outdoor lighting fixtures shall be consistent with the night sky regulations found in section 12-262. (E) Architectural Materials. Architectural materials are the visually exposed portions of the built environment. The long term quality and integrity of the materials and expression defines in the long term the built environment. (1) Principles. (a) Materials should be natural and authentic wherever possible where there is a high level of human contact with the building (notably at the ground level). (b) Materials should be long lasting and consistent in their expression with limited maintenance, particular attention to durability is essential at the ground level due to high traffic/use. (c) A range of materials and expressions are encouraged in the overall built environment, materials such as wood, stone, stucco, metal, etc. (d) It is expected that the materials used are consistent with the building expression. (e) In order to create an authentic mixed use environment as a whole, emphasis at the ground level is on the time honored materials and building traditions thus further promoting the "human scale". (f) Simulated materials are acceptable if used in locations where they are not in direct contact with people and have qualities that do not make them stand out as obviously "fake". (g) Where simulated materials are used (e.g. vinyl siding to simulate wood siding), materials with simpler details that look most convincing will be preferred. (h) Brick and stone veneers will be judged by both their finishes and the treatment at the corners, full corner pieces should be used to conceal thin-ness of veneer treatment. Veneers over massed volumes vs. single surfaces will also be preferred.

(Ord. of 2-6-08, § 1(Exh. A); Ord. No. 2009-6, § 4, 2-4-09; Ord. No. 2010-021, § 8, 9-7-10; Ord. No. 2012-28, § 2(Exh. A)(§ 12-32.524), 12-5-12)

Ask a question about Davie law

Corpus searches the Davie sections it holds and shows the ones that match, with their citations. Free, no sign-in.