§ 25-72 — Definitions
Code of Ordinances of the City of Davie, Florida (Codified through Ordinance No. O2026-016, enacted September 3, 2026 (Supp. No. 76)) · Davie Code of Ordinances § 25-72
Corpus is an independent public-information project, not the official City of Davie website. Stable reference: corpuslaw.us/code/ab883e97-b046-4070-bc5c-90c32b714b51
Sec. 25-72. - Definitions.
The following words, terms and phrases, when used in this article, shall have the meanings ascribed to them in this section, except where the context clearly indicates a different meaning: Air gap separation: Unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet supplying water to a tank, plumbing fixture, or other device and the flood level rim of such vessel. An "approved air gap separation" shall be at least double the diameter of the supply pipe measured vertically above the top of the rim of the vessel. In no case shall it be less than one (1) inch. Approved: Accepted by the town utilities or building departments as meeting an applicable specification stated or cited in this article, and is suitable for the proposed use. Atmospheric vacuum breaker: A backflow prevention device which is operated by atmospheric pressure in combination with the force of gravity. The unit is designed to work on a vertical plane only. The one moving part consists of a poppet valve which must be carefully sized to slide in a guided chamber and effectively shut off the reverse flow of water when a negative pressure exists. Backflow: The undesirable reversal of flow of non-potable water or other liquids, mixtures or substances under pressure into the water system from any source or sources other than its intended source. Backflow may take place through a cross connection and into the piping of a public water system or consumer's potable water system. There are two types of backflow: backpressure and backsiphonage. Backpressure: Backflow caused by a downstream pressure that is greater than the upstream or supply pressure in a public water system or consumer's potable water system. Backpressure (i.e.. downstream pressure that is greater than the potable water supply pressure) can result from an increase in downstream pressure, a reduction in the potable water supply pressure, or a combination of both. Increases in downstream pressure can be created by pumps, temperature increases in boilers, etc. Reductions in potable water supply pressure occur whenever the amount of water being used exceeds the amount of water being supplied, such as during water line flushing, fire fighting, or breaks in water mains. Backsiphonage: Backflow caused by a negative pressure (i.e., a vacuum or partial vacuum) in a public water system or consumer's potable water system. The effect is similar to drinking water through a straw. Backsiphonage can occur when there is a stoppage of water supply due to nearby firefighting, a break in a water main, or any other situation that causes a significant loss in water system pressure. Backflow prevention device: Any assembly, device or other means designed to prevent flow reversal through pipes or valves. Building official: The principal enforcing officer of the Florida Building Code within a particular jurisdiction. In the town, it shall be the building official. Certified backflow tester/technician: A person certified through one (1) of the following agencies as being competent to test, repair, overhaul, certify the operation, and make reports on backflow prevention devices: A.W.W.A. (American Water Works Association); F.W.P.C.O.A. (Florida Water Pollution Control Operator's Association); A.S.S.E (American Society of Sanitary Engineers); N.E.T.T.I (National Environmental Technology Training Institute); F.C.C.C.H.R. (Foundation for Cross Connection Control and Hydraulic Research); T.R.E.E.O- (Training Research and Education for Environmental Occupations); I.C.C.C. (Institution for Cross Connection Control); or By the device manufacturer's representative. Contamination: An impairment of the potable water supply by the introduction or admission of any foreign substance that degrades the quality and causes a health hazard. Cross connection: any physical connection or arrangement of piping or fixtures between two (2) otherwise separate pining systems, one of which contains potable water and the other non-potable water or industrial fluids through which, or because of which, backflow or backsiphonage may occur into the potable water system. Cross connection control: A connection between a reclaimed water system and a supplemental water supply with an approved backflow prevention device properly installed that will continuously afford the protection commensurate with the degree of hazard. Customer: The person, firm, corporation or other legal entity whose name or names appear on billing for a water service connection from the town. Degree of hazard: The term derived from an evaluation of the potential risk to public health and the adverse effect of the hazard upon the potable water system. Double check valve assembly: A device composed of two (2) single, independently acting check valves, including tightly closing shut-off valves located at each end of the device, plus properly located test cocks for the testing of each check valve. A check valve is a valve that is drip-tight in the normal direction of flow when the inlet pressure is one PSI (pound per square inch) and the outlet pressure is zero. The check valve shall permit no leakage in a direction reverse to the normal flow. The closure element (e.g.. clapper) shall be internally weighted or otherwise internally loaded to promote rapid and positive closure. Health hazard: Any condition, device, or practice in the potable water supply system and its operation which could create or, in the judgment of the utilities director, may create a danger to the health and well-being of the potable water consumer. An example of a health hazard is a structural defect including cross connection, in a potable water supply system. Owner: The person, firm, corporation or other legal entity that holds title to a property or premises. Plumbing hazard: A plumbing-type cross connection in a consumer's potable water system that has not been properly protected by a vacuum breaker, air gap separation, or backflow prevention device. Pollution hazard: An actual or potential threat to the physical properties of the potable water system or to the potability of the public or the consumer's potable water system which could constitute a nuisance or be aesthetically objectionable or could cause damage to the system or its appurtenances, but would not be dangerous to health. Potable water: Any water which, according to recognized standards, is safe for human consumption. Potable water service connection: The terminal end of a service connection from the public potable water system. Service connection shall also include connections from a fire hydrant and all other temporary or emergency connections from the utility system. Pressure vacuum breaker: A pressure vacuum breaker is similar to an atmospheric vacuum breaker except that the checking unit "poppet valve" is activated by a spring. This type of vacuum breaker does not require a negative pressure to react and can be used on the pressure side of a valve. Purveyor or water purveyor: The town's utilities department. Retrofit: Any work or modification to an existing facility. Reclaimed water service connection: The terminal end of a service connection from the reclaimed water system. Reduced pressure backflow preventer: A device containing within its structure a minimum of two (2) independently acting approved check valves, together with an automatically operating pressure differential relief valve located between the two (2) check valves. The first check valve reduces the supply pressure a predetermined amount so that during normal flow and at cessation of normal flow the pressure between the checks shall be less than the supply pressure. In case of leakage of either check valve, the differential relief valve, by discharging to the atmosphere, shall operate to maintain the pressure between the checks less than the supply pressure. The unit shall include tightly closine shutoff valves located at the each end of the device, and each device shall be fitted with properly located test cocks. Residential dual check valve: A compact unit manufactured with two independent spring actuated check valves. The residential dual check is acceptable only as added backflow prevention in areas served by reuse systems defined in Chapter 62-610. Part III. F.A.C. when the cross connection control program identifies activities specific to 62-555.360(5)(a) and 62-555.360(5)(b), F.A.C. Supplemental (auxiliary) water supply: Any water supply on or available to the premises other than the purveyor's approved public water supply. System hazard: An actual or potential threat of severe damage to the physical properties of the public potable water system or the consumer's potable water system or of a pollutant or contaminant which would have a protracted effect on the quality of the potable water in the system. Utilities director: The utilities director or his/her designee, in charge of the town utilities department, who is hereby invested with the authority and responsibility for the implementation of a cross connection control program and for the enforcement of the provisions of the applicable ordinance(s).
(Ord. No. 2013-5, § 2(Att. A), 2-20-13)
Ask a question about Davie law
Corpus searches the Davie sections it holds and shows the ones that match, with their citations. Free, no sign-in.
