Sec. 25-74. - Regulations.
(1) Town's requirements for cross connection control of properties served by its reclaimed water system are outlined in this section. Regulations regarding the use of other water resources to supplement reclaimed water supplies, including surface water, storm water and groundwater are also provided in this section per Rule 62-610.472, F.A.C. (a) No reclaimed water service shall be provided to the reclaimed water customers by the town unless the potable water supply and other supplemental water supplies are protected as required by this program and other applicable regulations. Service of reclaimed water to these premises shall be discontinued by the town if a backflow prevention device required by this program is not installed, tested, and maintained, or if it is found that a backflow prevention device has been removed, tampered with, bypassed, or if an unprotected cross connection exists on the premises. Service shall not be restored until such conditions or defects are corrected. (b) The owner, will own any required backflow prevention device, and will bear all costs associated with periodic testing, inspections, and maintenance of the device. (c) Any supplemental water supply pipes and appurtenances shall be color coded and marked to differentiate them from the reclaimed water and potable water facilities. (d) Reclaimed water customers that connect supplemental water supplies into the reclaimed water distribution system shall be located and documented in the record drawings for the reuse system and provide copies of these drawings to the town, through an appropriate permitting requirement. (e) The customer has the prime responsibility of preventing contaminants and pollutants from entering the public water main or water source from his/her reclaimed water system. He/she is also responsible to maintain cross connection control for any supplemental water supply proposed to be used when reclaimed water service is not available. A list of the backflow prevention equipment is provided in Table 75-73.1. (f) The customer shall protect his/her potable water system and all applicable supplemental water supplies against actual or potential cross connections, to prevent backflow, as required by this program and the Florida Building Code and other applicable regulations. The customer shall ensure that all protective devices are tested and maintained in the working condition required, and inspected. (g) An approved backflow prevention device may be required on the reclaimed water service line if the town determines it is necessary for the protection of the town's reclaimed water distribution system. The type of backflow protection device required shall depend upon the degree of hazard (Table 75-73.1.), If required, backflow prevention device shall be installed to the customer's reclaimed water system at or near the service connection and within the town's utility easement unless approved otherwise by the town administrator. In all cases, the backflow prevention device shall be in the first branch line leading off the service line, wherever the following conditions exist: (h) In the case of premises using public water supply as a supplemental water supply for reclaimed water use, the public water system shall be protected against backflow from the premises by an air gap separation as described in subsection XX. (i) In the case of any premises where there are cross connections that are not controlled, either actual or potential the public water system shall be protected by an approved air gap separation or an approved reduced pressure principle backflow prevention device at the service connection. (j) In the case of premises upon which any industrial fluids or any other objectionable substance is handled in such a fashion as to create an actual or potential hazard to the public water system and/or reclaimed water system, these public systems shall be protected against backflow from the premises by installing a backflow prevention device in the service line appropriate to the degree of hazard. This shall include the handling of process waters and waters originating from the utility system which have been subject to deterioration in quality. (k) In the case of premises having internal cross connections that cannot be permanently corrected and controlled, intricate plumbing and piping arrangements, or where entry to all portions of the premises is not readily accessible for inspection purposes, making it impracticable or impossible to ascertain whether or not dangerous cross connections exist, the public water system, supplemental water supplies and reclaimed water system shall be protected against backflow from the premises by installing a backflow prevention device in the service line. (l) In the case of any premises where, because of security requirements or other prohibitions or restrictions, it is impossible or impractical to make a complete cross connection survey, the public water system shall be protected against backflow or backsiphonage from the premises by the installation of a backflow prevention device in the service line. In this case, maximum protection will be required, that is, an approved air-gap separation or an approved reduction pressure principle backflow prevention device shall be installed in each service to the premises. (m) Installation of reclaimed water mains shall be in accordance to all requirements of Chapter 62-610, F.A.C. No cross connections to the potable water system shall be allowed. (n) Reclaimed water mains shall cross under potable water mains, unless not possible as determined by the town. Reclaimed water mains crossing potable water mains shall be laid to provide a minimum vertical distance of twelve (12) inches between the invert of the upper pipe and the crown of the lower pipe whenever possible. Where reclaimed water mains must cross a potable water main with less than the minimum required vertical distance, alternative construction variance as per Rule 62-555.314, F.A.C. shall be followed. (o) Maximum obtainable separation of reclaimed water lines and domestic water lines shall be practiced. A minimum horizontal separation of three (3) feet (outside to outside) shall be maintained as per Rule 62-555.314, F.A.C. between reclaimed water lines and either potable water mains or sewage collection lines. (p) Reclaimed water shall not be used to fill swimming pools, hot tubs, or wading pools. (q) Reclaimed water may be used to irrigate landscaped areas with a tank truck only if the following requirements are met: i. All applicable requirements in Part III of Chapter 62-610, F.A.C. ii. The truck used to transport and distribute reclaimed water is not used to transport potable water that is used for drinking water; and iii. The truck used to transport and distribute reclaimed water is not used to transport waters or other fluids that do not meet, at a minimum, the requirements of Part III of Chapter 62-610, F.A.C., unless the tank has been evacuated and properly cleaned prior to the addition of the reclaimed water. (2) Supplemental water supplies. According to the Rule 62-610.472(2), F.A.C., other water supplies may be used by the reclaimed water users to supplement the supply of reclaimed water, including but not limited to; surface, storm waters, ground waters, and potable water. Town of Davie reclaimed water customers may propose to use other water supplies only when reclaimed water from the town will not be available. In addition to potable water, Town of Davie proposed reclaimed water customers have already been using other water supplies including groundwater and surface water. These water supplies are planned to be used as supplemental only when reclaimed water will not be available. Approved backflow prevention devices shall be used by the reclaimed water customers, in order to avoid any contamination due to cross connection between reclaimed water system and other water supplies. Conditions from the Rule 62-610.472, F.A.C. applicable to the other water supplies proposed to be used as supplemental water supplies to the Town of Davie Reclaimed Water Supply are provided below. (3) Surface water and stormwater supplies. Surface and storm water supplies may be used to supplement the reclaimed water supply in the Town of Davie, if all of the conditions in Rule 62-610.472(3), F.A.C are met, Town of Davie reclaimed water users shall not introduce or mix the supplemental stormwater or surface water source directly to the town's reclaimed water distribution system. Conditions below for this use shall apply. (a) Operating protocols and reject storage facilities are not required for the supplemental water supply. (b) The supplemental water supply pipes and appurtenances shall be color coded and marked to differentiate them from the reclaimed water and potable water facilities. (c) A one-way flow device shall be provided on each surface water or stormwater supply line to prevent backflow of reclaimed water into the surface water or into the stormwater treatment facilities. This does not have to be an approved device as listed in Rule 62-555.360, F.A.C. A check valve, flap valve, or other device may be used. (4) Ground water supplies. Ground water supplies may be used to supplement the reclaimed water supply in Town of Davie, if all applicable conditions in Rule 62-610.472(4), F.A.C are met. Town of Davie reclaimed water users shall not introduce or mix the supplemental ground water source directly to the town's reclaimed water distribution system. Conditions below for this use shall apply. (a) An approved backflow prevention device, as described in this program and Rule 62-555.360, F.A.C., shall be provided on the pipe from each well connected into the reclaimed water system. (b) The supplemental water supply pipes and appurtenances shall be color coded and marked to differentiate them from the reclaimed water and potable water facilities. (c) Water withdrawn at a springhead shall be considered as "ground water." (5) Public water supplies. Drinking water from a public water supply system may be used to supplement the reclaimed water supply, if all applicable conditions in Rule 62-610.472(4), F.A.C are met. (a) An air gap separation, as described in this program and Rule 62-555.360, F.A.C., shall be provided on each connection from the public water supply system into the reclaimed water system. (b) The supplemental water supply pipes and appurtenances shall be color coded and marked to differentiate them from the reclaimed water facilities. (c) The number of connections from the public water supply system into the reclaimed water system shall be minimized. (6) Disconnection and penalty. (a) The town shall inform the reclaimed water customer by letter of any failure to comply with the conditions of this program or a permit issued hereunder. The compliance with the rules and applicable corrections will be defined in the town's reclaimed water ordinance. (b) If the town determines at any time that a serious threat to the public health exists, the appropriate service will be terminated immediately. (c) Any person who knowingly fails or refuses to obey or comply with, or willfully violates any of the provisions of this program, or any lawful rule or regulation promulgated hereunder, or any lawful order of the utilities director issued pursuant to the provisions of this program, shall, upon conviction of such offense, be subject to punishment as provided by law. Each day during which the knowing or willful failure or refusal to comply with this program continues shall constitute a separate offense. (d) Any person who violates any of the provision of this program shall be liable to the town for all costs and damages incurred by the town as a proximate result of such violation plus a fine up to five hundred dollars ($500.00) per day. (e) The Town of Davie cross connection control program engages both the town and its reclaimed water costumers responsible for the success of this program. The town shall create a permit and fee program for the cross connection program. Responsibilities of each party are stated in the following.
(Ord. No. 2013-5, § 2(Att. A), 2-20-13)
Ask a question about Davie law
Corpus searches the Davie sections it holds and shows the ones that match, with their citations. Free, no sign-in.