For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 6-33 — Minimum standards for interior of structures

Code of Ordinances of the City of Davie, Florida (Codified through Ordinance No. O2026-016, enacted September 3, 2026 (Supp. No. 76)) · Davie Code of Ordinances § 6-33

Corpus is an independent public-information project, not the official City of Davie website. Stable reference: corpuslaw.us/code/39c1c286-2efc-4e0a-8844-6e5181e16847

Sec. 6-33. - Minimum standards for interior of structures.

The interior of all structures and/or buildings governed by this chapter shall be properly maintained in accordance with the following standards. In addition to dwelling units, the interior of the structure shall, if applicable, include but not be limited to laundry rooms, storage rooms, meter rooms and recreational rooms and all other shared and/or public areas. (a) Electrical equipment, maintenance and installation requirements. (1) All electrical switches, electrical outlets, electrical wiring and other electrical fixtures shall be installed and maintained so as to avoid the possibility and danger of electrical shock or malfunction and must be maintained in good working condition. (2) All electrical switches, electrical outlets and other electrical fixtures shall be installed and maintained. (3) Every public hall, public stairway and other non-habitable public space or area located within or on the exterior of the structure shall be provided with properly installed electric lighting facilities capable of providing illumination throughout. (4) Every habitable room shall have electric outlets and/or electric fixtures properly connected to a source of power. There shall be a minimum of one (1) outlet and one (1) fixture or two (2) outlets. (5) Every bathroom, shower room, toilet room or compartment, located in a structure used for human habitation, shall have permanently installed artificial lighting fixtures. The switches shall be so located as to avoid danger of electrical hazards. (b) Plumbing, sanitary facilities and related equipment maintenance and installation requirements. Each dwelling unit shall have not less than the following: (1) A flush water closet, lavatory basin and a bathtub or shower shall be required for every dwelling unit; (2) All plumbing fixtures shall be properly connected to approved water, sewer or gas systems. Where a sewer system is not available, drain lines shall be connected to an approved septic tank. (3) Every plumbing fixture, water pipe, waste pipe, gas line and drain line shall be maintained in good working condition and free of leaks, defects and obstructions. (4) An approved type kitchen sink, lavatory basin, bathtub and shower shall be supplied with hot and cold water. Hot water shall mean water heated to a temperature of not less than one hundred twenty (120) degrees Fahrenheit measured at faucet outlet; all water heating facilities shall be properly installed, connected and maintained in a safe and good working condition. (c) Each unit shall provide privacy for accessibility to toilet and bath facilities. (1) All water closets, urinals, bathtubs and showers shall be located in a room or rooms which afford privacy to the user; (2) Rooms containing water closets, urinals, bathtubs or showers shall be not more than one (1) story removed from the rooming unit of any occupant sharing the facilities; (3) All toilet and bath facilities shall be so located so as to be accessible with out going outside of the building or without going through a dwelling unit, or rooming unit of another occupant; (4) No electric water heater shall be allowed in any bathroom unless the water heater and all electrical connections are totally encased in a non-conductive material or the water heater is installed in such a manner as to avoid any probability of shock hazard; (5) Every occupied dwelling unit shall have proper utility connections for cooking facilities. (d) Ventilation equipment, maintenance and installation requirements. (1) Every habitable room shall have at least one window with a minimum total area of not less than ten (10) percent of the floor area of the room or a skylight with a minimum total area of not less than fifteen (15) percent of the floor area of the room, except windows or skylights shall not be required in those bathrooms, shower rooms and water closet compartments equipped with an adequate and properly functioning ventilating system which was permitted and inspected in accordance with the Florida Building Code. (2) All windows and skylights shall face or open directly to a non-habitable area. (3) Every habitable room shall be ventilated directly outdoors. Such ventilation shall be provided by an open area equal to fifty (50) percent of the required minimum window or skylight area or by satisfactory mechanical ventilation complying with the Florida Building Code. (e) Pests, insects and rodent extermination requirement. The owner shall be responsible to make reasonable provisions for extermination on the following cases, except as provided by F.S. § 83.51: (1) When infestation exists in one or more units of a multiple-unit structure. (2) When infestation exists in shared or public areas of a multiple-unit structure. (f) Windows and screens. (1) Every window other than a fixed window shall be capable of being easily opened and closed, be equipped with fully operable hardware, have a functional locking device and kept in good working condition. (2) All screens shall be free of holes, tears or other defects and maintained in a good state of repair. (3) Every window shall be weather-tight, maintained without cracks and/or holes and kept in a good state of repair. (g) Exterior doors. (1) Every exterior door shall be capable of being easily opened and closed, be equipped with fully operable hardware, have a functional locking device and be kept in a good state of repair. (2) Every exterior door and supplied screen door shall be weathertight, weatherproof, maintained without cracks and/or holes and kept in a good state of repair. (h) Porches, balconies, decks, exterior stairs, walkways and appurtenances. (1) Every porch, balcony, deck, exterior stairs, walkways and every appurtenance thereto shall be constructed and maintained so as to be safe and capable of supporting the loads for which it is intended and used, and shall be kept in a good state of repair. (2) All protective railings or protective handrails shall be capable of supporting the load to which it is intended and subjected and kept in a good state of repair. (i) Supplied facilities and equipment. (1) Every supplied facility and piece of equipment including but not limited to heating units, air conditioners, washing machines and clothes dryers, etc., intended to be utilized by a tenant or occupant shall be installed and maintained in a legal, safe, and sanitary manner and kept in good working and operable condition.

(Ord. No. 2010-9, § 2(6-15.11), 4-7-10)

Ask a question about Davie law

Corpus searches the Davie sections it holds and shows the ones that match, with their citations. Free, no sign-in.