§ 10-11 — Amendments to NFPA 1 Sections 18.3, 18.4, and 18.5 of the Florida Fire Prevention Code

Code of Ordinances, City of Gainesville, Florida (Supp. No. 64, Update 1: codified through Ordinance No. 2024-740, adopted November 6, 2025) · Gainesville City Code § 10-11

Corpus is an independent public-information project, not the official City of Gainesville website. Stable reference: corpuslaw.us/code/2da404ce-5aca-42c8-b416-ef26217e5a84

Sec. 10-11. - Amendments to NFPA 1 Sections 18.3, 18.4, and 18.5 of the Florida Fire Prevention Code.

NFPA 1 Sections 18.3, 18.4, and 18.5 are amended by adding the following: (1) Every water supply for fire protection use shall be designed and installed in accordance with the Gainesville Regional Utilities "Potable Water, Wastewater & Reclaimed Water Design Standards and Construction Details, and Material Standards Manual." (2) The fire protection water supply for a building equipped with an automatic fire sprinkler system shall be designed and installed so as to provide an adequate fire flow in accordance with Section 18.4 of the 2012 edition of NFPA 1. The fire protection water supply for a building not equipped with an automatic fire sprinkler system shall be designed and installed so as to provide an adequate fire flow in accordance with the greater requirement of either Section 18.4 of the 2012 edition of NFPA 1, or the 2008 edition of the Guide for Determination of Required Fire Flow, published by Insurance Service Office. One copy of the ISO guide and one copy of Section 18.4 of the 2012 edition of NFPA 1 shall be kept in the office of the City Clerk for public use, inspection and examination. The provisions of this subsection notwithstanding, the fire flow requirements may be varied at the discretion of the Fire Chief or designee if such official finds that adequate fire protection can be provided without such fire flow and/or the building is provided with a fully automatic fire extinguishing system. (3) Where the fire protection water supply is not provided by the central water distribution system, it shall be separate and distinct from any domestic water supply provided by the central water distribution system. (4) The installation of the fire protection water supply shall be coordinated with the installation of other underground utilities to be located on the property. A water supply for fire protection, either temporary or permanent, shall be made available as soon as combustible material accumulates. Where underground water mains and hydrants are to be provided, they shall be installed, completed, and in service prior to building construction work. (5) Where the fire protection water supply is provided by an extension of the central water distribution system, the extension, if approved and accepted by GRU, shall be conveyed to the city, at no cost to the city, together with any necessary easements to permit city maintenance of the water supply. (6) All costs associated with the construction and installation of a water distribution system extension, including the cost of inspection services performed by the city, shall be paid in full by the owner or developer prior to acceptance of the extension by the city. (7) The number of fire hydrants required for a project will be determined based on the fire flow demand calculations identified in (2) above. One hydrant will be required for each 1,000 GPM of demand, with at least one hydrant located within 500 feet of the most remote point of the building, as the fire truck drives. The remaining hydrants shall be located within 1,000 feet of the most remote point of the building, as the fire truck drives. All fire hydrants shall meet the fire hydrant standards of this section and the Gainesville Regional Utilities "Potable Water, Wastewater & Reclaimed Water Design Standards and Construction Details, and Material Standards Manual." (8) The provisions in subsection (7) notwithstanding, the fire hydrant requirements may be varied at the discretion of the Fire Chief or designee if adequate fire protection can be provided from an approved fire hydrant that does not meet such requirements and/or a fully automatic fire extinguishing system. (9) No hydrant shall be installed that is not capable of providing at minimum a 1,000 GPM or greater flow. The water distribution system supplying the hydrants must be capable of providing at minimum a 1,500 GPM or greater flow. (10) Cost of reconstruction. Where a portion of the central water distribution system must be reconstructed to meet the requirements of this section, the owner or developer will be assessed any costs incurred by the city in accordance with Section 27-99 of the City of Gainesville Code of Ordinances. (11) Access during construction or alteration. During construction or alteration of any building, access to the building and any hydrant that serves any portion of the building shall be provided for fire protection purposes without interference or obstruction. (12) Prohibitions. It shall be unlawful for any person to construct, or cause to be constructed, any building that does not meet the requirements of this section unless the requirements have been varied by the Fire Chief designated in this article as being authorized to vary such requirements. It shall also be unlawful to alter, cause to be altered, occupy or allow to be occupied any building constructed after August 10, 1981, that does not meet the requirements of this section unless the requirements have been varied as provided in this section.

(Ord. No. 002251, § 1, 9-9-02; Ord. No. 080841, § 4, 5-7-09; Ord. No. 120051, § 2, 9-6-12; Ord. No. 140495, § 4, 3-5-15)